147 views

1 Answer

Answer :

In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

Like 0 like

Please log in or register to answer this question.

Related questions

726 views

Last Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

1 answer
78 views

Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

1 answer
117 views

Description : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

1 answer
892 views

Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

1 answer
216 views

Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

1 answer
106 views

Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

1 answer
409 views

Description : State the modification to be done in dc series motor to work satisfactorily as ac series motor. State applications of ac series motor.

Last Answer : Modifications are necessary in a dc series motor so that it operates satisfactorily on ac supply. The modifications are as follows:  1) AC series motor is built with a few field turns as ... and grinders 5) High speed vacuum cleaners 6) Sewing machines 7) Food processors 8) Drilling machine 

1 answer
138 views

Last Answer : A.C. series motor as compared to D.C. series motor has smaller brush width, less number of field turns, more number of armature turns, less air gap.

1 answer
95 views

Last Answer : If a D.C. series motor is operated on A.C. supply, it will spark excessively, have poor efficiency, have poor power factor.

1 answer
165 views

Last Answer : In a A.C. series motor armature coils are usually connected to commutator through resistance.

1 answer
121 views

Last Answer : When a D.C. series motor is connected to A.C. supply, the power factor will be low because of high inductance of field and armature circuits.

1 answer
92 views

Description : Damper winding in a synchronous motor

Last Answer : Damper winding in a synchronous motor Serves to start the motor.

1 answer
358 views

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

1 answer
127 views

Last Answer : The starting winding of a single-phase motor is placed in stator.

1 answer
240 views

Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

1 answer
219 views

Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

1 answer
229 views

Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

1 answer
115 views

Last Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

1 answer
87 views

Last Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

1 answer
264 views

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

1 answer
163 views

Description : The damping winding in synchronous motor is generally used to?

Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

1 answer
518 views

Description : In synchronous motor, does the winding losses vary with load?

Last Answer : No, in the synchronous motor the winding losses do not vary with load.

1 answer
493 views

Last Answer : In a low power factor wattmeter the compensating coil is connected in series with pressure coil.

1 answer
156 views

Last Answer : Compensating windings are used in D.C. generators to neutralise the cross-magnetising effect of the armature reaction.

1 answer
98 views

Description : In case of conductively compensated D.C. series motors, the compensating winding is provided?

Last Answer : In case of conductively compensated D.C. series motors, the compensating winding is provided in series with armature winding.

1 answer
147 views

Description : Write two applications of D.C. series motor. 

Last Answer : The applications of D.C. series motor: 1. Cranes 2. Hoists 3. Trolley and cars 4. Conveyors 5. For traction work i.e. electric locomotives 6. Elevator 7. Air compressor

1 answer
329 views

Description : Brake test on DC series motor

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

2 answers
146 views

Description : Describe the reason of using dc series motor for electric trains.

Last Answer : Electric trains require an inverse torque speed characteristics for proper operation. That is a higher torque is required at start (when speed is nil or low) and as the train picks up ... torque - speed characteristics of DC series motors match, these motors are suitable for electric trains

1 answer
123 views

Description : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is :

Last Answer : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is : 0.075

1 answer
522 views

Last Answer : In a D.C. series motor, if the armature current is reduced by 50%, the torque of the motor will be equal to 25% of the previous value.

1 answer
119 views

Last Answer : The speed of a D.C. series motor is inversely proportional to the armature current.

1 answer
86 views

Last Answer : A D.C. series motor is that which has its field winding consisting of thick wire and less turns.

1 answer
191 views

Last Answer : The direction of rotation of a D.C. series motor can be changed by interchanging field terminals.

1 answer
93 views

Description : What are the advantages of DC series motor?

0 answers
635 views

Description : Why dc series motor should not be started at no load?

0 answers
87 views

Description : Why a dc series motor has a high starting torque?

Last Answer : motor

1 answer
65 views

Description : Explain series switching control of AC load. Single phase resistance load - Integral half cycle control Phase control - Resistance load

0 answers
201 views

Description : Explain magnetic effect employed in measuring instrument.

Last Answer : Magnetic Effect:  I) In PMMC meters:  ➢ When a current is passed through a conductor, magnetic field is produced round the conductor. Due to this field when current ... field it experiences a mechanical force.  Examples: Electrodynamometer type instruments, Induction type instrument. 

1 answer
142 views

Description : List any four effects employed in measuring instruments.

Last Answer : Effects Employed in Measuring Instruments: 1. Magnetic Effect 2. Electromagnetic induction 3. Heating effect 4. Electrostatic effect 5. Hall Effect 

1 answer
1.2k views

Description : Reflector mirrors employed for exploiting solar energy are called the  (1) Mantle (2) Heliostats (3) Diffusers (4) Ponds

Last Answer : Reflector mirrors employed for exploiting solar energy are called the Heliostats

1 answer
135 views

Last Answer : Oil switches are employed for high voltages and large currents circuits.

1 answer
157 views

Description : The direction of rotation of an inverter fed 3-phase ac motor is reversed by (A) a mechanical reversing switch (B) reversing the input dc link voltage (C) operating the inverter as a rectifier (D) changing the sequence of switching

Last Answer : The direction of rotation of an inverter fed 3-phase ac motor is reversed by changing the sequence of switching

1 answer
111 views

Last Answer : If a D.C. motor is connected across the A.C. supply it will burn due to heat produced in the field winding by eddy currents.

1 answer
61 views

Description : What are the parts of AC motor?

0 answers
69 views

Description : What is the principle of AC motor?

0 answers
102 views

Last Answer : Induction motor is a AC motor it is also known as asynchronous motor .

1 answer
106 views

Description : AC motor

Last Answer : AC motor AC motor have two types one is Induction motor and second is synchronous motor. Induction motor have two types one is single phase induction motor and second is three phase ... self starting motor so using  external motor or we have to start it as induction motor.

1 answer
500 views

Description : State advantages of short pitch winding over full pitch winding in alternators. 

Last Answer : Advantages of Short Pitch Winding over Full Pitch Winding in Alternators: 1) Short pitching reduces the amount of copper needed for end connection when compared with full pitched coil. 2) They ... reduced, thereby increasing the efficiency. 4) The power quality of generated emf is improved. 

1 answer
107 views

Last Answer : It is the wire wound around a aluminium metal it is found commonly in transformers or motors

1 answer
236 views

Description : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Last Answer : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

1 answer
...