113 views

1 Answer

Answer :

In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.

Like 0 like

Please log in or register to answer this question.

Related questions

100 views

Description : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

1 answer
230 views

Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

1 answer
138 views

Last Answer : If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in damage to the starting winding.

1 answer
68 views

Description : Why the speed of synchronous motor is constant?

0 answers
96 views

Description : Reluctance motor

Last Answer : Reluctance motor Reluctance is opposition to magnetic flux. Reluctance is analogous to electric resistance. Reluctance motor does not have any winding on rotor. Rotor consists of  ... for rotation of rotor is generated through magnetic reluctance so it called reluctance motor.

1 answer
125 views

Last Answer : The operating speed of a synchronous motor can be changed to new fixed value by changing frequency.

1 answer
108 views

Description : If we change the excitation of synchronous machine will it affect on motor speed?

Last Answer : No, If we change the excitation of synchronous machine it will not affect on motor speed.

1 answer
95 views

Description : Synchronous motor always runs at which speed?

Last Answer : Synchronous motor always runs at synchronous speed.

1 answer
210 views

Description : The synchronous speed of an 8 pole induction motor supplied power from a 50 Hz source will be ?

Last Answer : Ns         equals        f/pair pole 50/4      - 12.5

2 answers
75 views

Description : Why synchronous motor Cannot start itself?

0 answers
584 views

Description : The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

Last Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

1 answer
571 views

Description : A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be

Last Answer : Leading

2 answers
519 views

Description : In synchronous motor, does the winding losses vary with load?

Last Answer : No, in the synchronous motor the winding losses do not vary with load.

1 answer
144 views

Last Answer : As the load is increased the speed of D.C. shunt motor will reduce slightly.

1 answer
158 views

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

1 answer
92 views

Description : Damper winding in a synchronous motor

Last Answer : Damper winding in a synchronous motor Serves to start the motor.

1 answer
80 views

Description : How can we improve power factor using synchronous motor?

0 answers
74 views

Description : What is the principle of synchronous motor?

0 answers
70 views

Description : What is the use of synchronous motor?

0 answers
113 views

Last Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

1 answer
261 views

Description : what is the difference between synchronous and asynchronous motor?

Last Answer : Asynchronous motors and syncrouns motor are called as dc machines.  and also syncrouns motor called as induction motor. Asynonymous motor as are rotates with constant speed we not able to operate . ... It is able to operate. These are a small difference between syncrouns and asynchronous motors. 

2 answers
137 views

Last Answer : The speed of a D.C. shunt motor can be increased by increasing the resistance in field circuit.

1 answer
498 views

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

1 answer
166 views

Last Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

1 answer
179 views

Last Answer : The speed/load characteristics of a universal motor is same as that of D.C. series motor.

1 answer
101 views

Description : Hunting in synchronous motor cannot be due to?

Last Answer : Hunting in synchronous motor cannot be due to windage friction.

1 answer
204 views

Last Answer : A synchronous motor running with normal excitation adjusts to load increases essentially by increase in armature current.

1 answer
310 views

Description : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Last Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

1 answer
228 views

Last Answer : The coupling angle or load angle of synchronous motor is defined as the angle between the rotor and the stator poles of opposite polarity.

1 answer
121 views

Last Answer : If the synchronous motor, properly synchronised to the supply is running on no load and is having negligible loss then the stator current will be zero.

1 answer
178 views

Description : The synchronous motor which works on leading power factor and does not drive any mechanical load is called?

Last Answer : The synchronous motor which works on leading power factor and does not drive any mechanical load is called synchronous condenser.

1 answer
107 views

Description : In a synchronous motor which losses varies with load?

Last Answer : In a synchronous motor, copper losses varies with load.

1 answer
250 views

Description : The synchronous motor will develop maximum power when the load angle is?

Last Answer : The synchronous motor will develop maximum power when the load angle is 900.

1 answer
261 views

Last Answer : In case one phase of a three-phase synchronous motor is short-circuited the motor will not start.

1 answer
265 views

Description : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque  (1) Decreases (2) Increases (3) Remains constant (4) None of the above

Last Answer : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque Increases 

1 answer
164 views

Description : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min (A) 100 rpm (B) 200 rpm (C) 400 rpm (D) 800 rpm

Last Answer : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min 200 rpm

1 answer
67 views

Last Answer : In variable speed motor a weaker commutating field is needed at low speed than at high speed.

1 answer
106 views

Last Answer : Series motor has the poorest speed control.

1 answer
424 views

Description : The speed of a D.C. motor can be controlled by varying  1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above

Last Answer : The speed of a D.C. motor can be controlled by varying  1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above

1 answer
120 views

Last Answer : The speed of a D.C. series motor is inversely proportional to the armature current.

1 answer
92 views

Last Answer : In a D.C. shunt motor, speed is independent of armature current.

1 answer
119 views

Last Answer : The speed of a universal motor is usually reduced by using gearing.

1 answer
108 views

Last Answer : Speed control of a universal motor is achieved by varying field flux with tapped field windings, connecting rheostat in series, applying variable voltage by means of silicon controlled rectifier, applying variable voltage by means of variable auto-transformer.

1 answer
174 views

Last Answer : Speed torque characteristic of a repulsion induction motor is similar to that of a D.C. compound motor.

1 answer
105 views

Last Answer : The speed control of universal motor used for sewing machines is by varying the resistance.

1 answer
273 views

Description : What are the speed control methods of dc motor?

Last Answer : Field control of DC motor Armature control of DC motor

2 answers
393 views

Description : speed control methods of three phase induction motor?

Last Answer : Speed control of three phase induction motor

2 answers
171 views

Description : List different starting methods of three phase synchronous motor. Explain any one of them.

Last Answer : Different Starting Methods of Three Phase Synchronous Motor: As synchronous motor is not self starting, different methods of starting are as follows: 1) By using an Induction (Pony) motor 2) ... . The rotor gets pulled into synchronism and starts running at constant speed as a synchronous motor. 

1 answer
527 views

Description : Draw and explain V and inverted V curves for synchronous motor.

Last Answer : V curves' and inverted V curves' for Synchronous Motor:  V curve:  V curve is a plot of the stator current versus field current for different constant loads. The graph is plotted ... Vcurves of synchronous motor. The highest point on each of these curves indicates unity power factor.

1 answer
...