127 views

1 Answer

Answer :

The starting winding of a single-phase motor is placed in stator.

Like 0 like

Please log in or register to answer this question.

Related questions

240 views

Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

1 answer
219 views

Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

1 answer
216 views

Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

1 answer
91 views

Last Answer : The rotor developed by a single-phase motor at starting is zero.

1 answer
892 views

Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

1 answer
142 views

Last Answer : Capacitor start motor has high torque in starting

1 answer
87 views

Last Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

1 answer
166 views

Description : How is a three phase cage induction motor self starting?

Last Answer : Any type of induction motor is self starting. Because the reason for torqe production require two flux displaced by some angle theta.If theta is constant with time then torqe will be constant;if ... torqe also pulsating. In induction motor this angle theta is not pulsating.so it is self starting 

1 answer
98 views

Description : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in ... increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor

Last Answer : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then the flux first decreases and then increases in the same direction

1 answer
92 views

Description : Damper winding in a synchronous motor

Last Answer : Damper winding in a synchronous motor Serves to start the motor.

1 answer
358 views

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

1 answer
230 views

Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

1 answer
115 views

Last Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

1 answer
519 views

Description : In synchronous motor, does the winding losses vary with load?

Last Answer : No, in the synchronous motor the winding losses do not vary with load.

1 answer
117 views

Description : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

1 answer
140 views

Description : In a double squirrel cage induction motor, good starting torque is produced as (A) Large current flows through the outer high resistance winding. (B) Large current flows through the inner high ... the outer high resistance winding. (D) Large current flows through the inner low resistance winding.

Last Answer : In a double squirrel cage induction motor, good starting torque is produced as Large current flows through the outer high resistance winding.

1 answer
166 views

Last Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

1 answer
169 views

Last Answer : The starting resistance of a D.C. motor is generally low.

1 answer
129 views

Last Answer : For starting a D.C. motor a starter is required because it limits the starting current to a safe value.

1 answer
116 views

Description : Is induction motor is self starting?

Last Answer : Single phase induction motor is not self starting. Three phase induction motor is self starting.

1 answer
78 views

Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

1 answer
106 views

Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

1 answer
171 views

Description : List different starting methods of three phase synchronous motor. Explain any one of them.

Last Answer : Different Starting Methods of Three Phase Synchronous Motor: As synchronous motor is not self starting, different methods of starting are as follows: 1) By using an Induction (Pony) motor 2) ... . The rotor gets pulled into synchronism and starts running at constant speed as a synchronous motor. 

1 answer
140 views

Description : In a single-phase induction motor, the operating direction is determined by the ________ A) Rotor B) Stator C) Starting circuit D) None of these

Last Answer : In a single-phase induction motor, the operating direction is determined by the Starting circuit

1 answer
160 views

Description : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α

Last Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

1 answer
76 views

Last Answer : A single-phase induction motor is inherently non-self-starting with low torque.

1 answer
222 views

Last Answer : The power factor of a single-phase induction motor is usually lagging.

1 answer
234 views

Last Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

1 answer
222 views

Last Answer : In a shaded pole single-phase motor, the revolving field is produced by the use of shading coils.

1 answer
107 views

Last Answer : If the capacitor of a single-phase motor is short-circuited the motor will not start.

1 answer
147 views

Last Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

1 answer
264 views

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

1 answer
163 views

Description : The damping winding in synchronous motor is generally used to?

Last Answer : The damping winding in synchronous motor is generally used to provide starting torque and prevent hunting.

1 answer
102 views

Last Answer : The value of starting capacitor of a fractional horse power motor will be 300 uF .

1 answer
134 views

Description : A synchronous motor can be made self starting by providing?

Last Answer : A synchronous motor can be made self-starting by providing damper bar.

1 answer
87 views

Description : Why a dc series motor has a high starting torque?

Last Answer : motor

1 answer
114 views

Description : Why starter is required for starting an induction motor?

0 answers
148 views

Description : Why does induction motor have high starting current?

Last Answer : In induction motor , the flux produce is quadrature to the applied voltage. Since when we are going to start motor , there is no flux present inside . So in order to lets say compensate it ... times of current to further increase flux. So that is reason for high starting current in induction motor

2 answers
101 views

Description : Damper winding is provided in 3 phase synchronous motors to :

Last Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

1 answer
135 views

Last Answer : The capacitors used in single-phase capacitor motors have no polarity marking.

1 answer
3.4k views

Description : A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer

Last Answer : A Resistance thermometer is used to measure the stator % winding temperature of the generator. 

1 answer
604 views

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

1 answer
625 views

Description : Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

1 answer
358 views

Last Answer : In D.C. machines fractional pitch winding is used to reduce the sparking.

1 answer
121 views

Last Answer : Buses, trains, trolleys, hoists, cranes require high starting torque and therefore make use of D.C. series motor.

1 answer
892 views

Last Answer : The ratio of starting torque to full-load torque is least in case of shunt motors.

1 answer
87 views

Last Answer : A direct online starter is used for starting motors up to 5 H.P.

1 answer
203 views

Last Answer :  Sandwich type winding is used in 3 phase shell-type transformer.

1 answer
224 views

Description : Single-phase mid-point controlled rectifier with RL load

Last Answer : Single-phase mid-point controlled rectifier with RL load : The circuit configuration of single-phase midpoint controlled rectifier is shown in the figure. During positive half-cycle of ... some part of next positive half-cycle of voltage with reversed polarity can appear across load.

1 answer
...