Please Log in or Register for more.


378 views

1 Answer

Answer :

When two D.C. series motors are connected in parallel, the resultant speed is normal speed.

Like 0 like

Please log in or register to answer this question.

Related Questions


In case of conductively compensated D.C. series motors, the compensating winding is provided?
Last Answer : In case of conductively compensated D.C. series motors, the compensating winding is provided in series with armature winding.

Show More

97 views 1 answer








Last Answer : In case of D.C. shunt motors the speed is dependent on back e.m.f. only because flux is practically constant in D:C. shunt motors.

Show More

250 views 1 answer








Last Answer : During rheostat braking of D.C. series motors motor is run as a generator.

Show More

85 views 1 answer








Last Answer : The speed of a D.C. series motor is inversely proportional to the armature current.

Show More

114 views 1 answer








Last Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Show More

710 views 1 answer








Last Answer : In D.C. shunt motors as load is reduced the speed will remain almost constant.

Show More

145 views 1 answer








Last Answer : Starters are used with D.C. motors because to restrict armature current as there is no back e.m.f. while starting.

Show More

119 views 1 answer








Last Answer : Differentially compound D.C. motors can find applications requiring low starting torque.

Show More

125 views 1 answer







Describe the reason of using dc series motor for electric trains.
Last Answer : Electric trains require an inverse torque speed characteristics for proper operation. That is a higher torque is required at start (when speed is nil or low) and as the train picks up ... torque - speed characteristics of DC series motors match, these motors are suitable for electric trains

Show More

142 views 1 answer







In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is :
Last Answer : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is : 0.075

Show More

109 views 1 answer








Last Answer : In a D.C. series motor, if the armature current is reduced by 50%, the torque of the motor will be equal to 25% of the previous value.

Show More

503 views 1 answer








Last Answer : A D.C. series motor is that which has its field winding consisting of thick wire and less turns.

Show More

82 views 1 answer








Last Answer : The direction of rotation of a D.C. series motor can be changed by interchanging field terminals.

Show More

184 views 1 answer








Last Answer : A.C. series motor as compared to D.C. series motor has smaller brush width, less number of field turns, more number of armature turns, less air gap.

Show More

135 views 1 answer








Last Answer : If a D.C. series motor is operated on A.C. supply, it will spark excessively, have poor efficiency, have poor power factor.

Show More

91 views 1 answer







Why are DC motors used in trains and not AC motors ?
Last Answer : The reason is torque. torque is inversely proportional to speed..i.e when th knowe train comes to rest position to motion.. initial speed is zero..so it requires high starting torque for ... current will flow through field and armature coils then maximum torque is available at the intial condition.

Show More

160 views 1 answer







Which of the following motors can run on both AC and DC? A) Universal motor B) Dual wattage motor C) Flexible motor D) All the above
Last Answer : Which of the following motors can run on both AC and DC? A) Universal motor B) Dual wattage motor C) Flexible motor D) All the above

Show More

179 views 1 answer








Last Answer : D.C. shunt motors are used for driving machine tools.

Show More

85 views 1 answer








Last Answer : The D.C. motors preferred for traction applications beacuse the speed is inversely proportional to the torque and the torque is proportional to square of armature current.

Show More

159 views 1 answer







We connected a 35V dc supply to a resistance of 600 Ohm in series with an unknown resistance R.A. voltmeter having a resistance of 1.2 kOhm is connected across 600 Ohm resistance and read 5v. The value of resistance R will be
Last Answer : We connected a 35V dc supply to a resistance of 600 Ohm in series with an unknown resistance R.A. voltmeter having a resistance of 1.2 kOhm is connected across 600 Ohm resistance and read 5v. The value of resistance R will be 2.4 kOhm

Show More

149 views 1 answer







A DC voltage source is connected across a series RLC circuit. Under steady-state conditions, the applied DC voltage drops entirely across the
Last Answer : A DC voltage source is connected across a series RLC circuit. Under steady-state conditions, the applied DC voltage drops entirely across the C only

Show More

2.0k views 1 answer








Last Answer : When a D.C. series motor is connected to A.C. supply, the power factor will be low because of high inductance of field and armature circuits.

Show More

119 views 1 answer








Last Answer : If  equalising bar is connected to the 2 DC generators  the current will be equal in 2 generators irrespective of parallel connection so that we connect equaliser bar

Show More

165 views 2 answers







A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be
Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Show More

481 views 1 answer







The fall in speed of a dc generator due to increase in load can be corrected by  (1) cooling the armature.. (2) increasing the excitation. (3) reducing the load voltage. (4) increasing the input to the prime mover
Last Answer : It   can  be  corrected  by  increasing  the  input  to  the  prime  mover.

Show More

355 views 2 answers







The speed of a D.C. motor can be controlled by varying  1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above
Last Answer : The speed of a D.C. motor can be controlled by varying  1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above

Show More

388 views 1 answer








Last Answer : The speed of a D.C. shunt motor can be increased by increasing the resistance in field circuit.

Show More

134 views 1 answer








Last Answer : As the load is increased the speed of D.C. shunt motor will reduce slightly.

Show More

142 views 1 answer








Last Answer : In a D.C. shunt motor, speed is independent of armature current.

Show More

87 views 1 answer







What are the speed control methods of dc motor?
Last Answer : Field control of DC motor Armature control of DC motor

Show More

252 views 2 answers







State the modification to be done in dc series motor to work satisfactorily as ac series motor. State applications of ac series motor.
Last Answer : Modifications are necessary in a dc series motor so that it operates satisfactorily on ac supply. The modifications are as follows:  1) AC series motor is built with a few field turns as ... and grinders 5) High speed vacuum cleaners 6) Sewing machines 7) Food processors 8) Drilling machine 

Show More

378 views 1 answer







Brake test on DC series motor
Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Show More

298 views 2 answers







What are the advantages of DC series motor?

Show More

92 views 0 answers







Why dc series motor should not be started at no load?

Show More

629 views 0 answers







Why a dc series motor has a high starting torque?
Last Answer : motor

Show More

86 views 1 answer







Damper winding is provided in 3 phase synchronous motors to :
Last Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Show More

93 views 1 answer







Stepper motors are used in  (1) printers (2) lifts (3) amplifiers (4) oscillators
Last Answer : Stepper motors are used in printers 

Show More

68 views 1 answer







Slot harmonics are reduced in induction motors by using (A) fractional-pitch windings (B) fractional-slot windings (C) integral-slot windings (D) distributed windings
Last Answer : Slot harmonics are reduced in induction motors by using fractional-slot windings

Show More

79 views 1 answer







Generally, Crawling in squirrel cage induction motors is tendency to run stably at speeds as low as (A) One-third of their synchronous speed (B) One-fifth of their synchronous speed (C) One-seventh of their synchronous speed (D) One-ninth of their synchronous speed
Last Answer : Generally, Crawling in squirrel cage induction motors is tendency to run stably at speeds as low as One-seventh of their synchronous speed

Show More

102 views 1 answer







Which of the following test is usually conducted to determine the efficiency of traction motors ? (A) Field’s test (B) Swinburne’s test (C) Hopkinson’s test (D) Retardation test.
Last Answer : Which of the following test is usually conducted to determine the efficiency of traction motors ? (A) Field’s test (B) Swinburne’s test (C) Hopkinson’s test (D) Retardation test.

Show More

248 views 1 answer







Which of the following motors is being extensively used in servo applications ? A. AC motor B. Field controlled dc motor C. Armature controlled dc motor D. None of these
Last Answer : Which of the following motors is being extensively used in servo applications ? A. AC motor B. Field controlled dc motor C. Armature controlled dc motor D. None of these

Show More

203 views 1 answer








Last Answer : A direct online starter is used for starting motors up to 5 H.P.

Show More

82 views 1 answer








Last Answer : The capacitors used in single-phase capacitor motors have no polarity marking.

Show More

133 views 1 answer








Last Answer : Most of the fractional horsepower motors have either plain or sleeve bearings.

Show More

92 views 1 answer








Last Answer : As hysteresis motors are free from mechanical and magnetic vibrations therefore these are considered as suitable for sound equipment.

Show More

115 views 1 answer







What are the five types of single phase motors used in the industry?

Show More

79 views 0 answers







What is the difference between synchronous and asynchronous motors?
Last Answer : The motor which rotates at constant speed is called synchronous motor. And that constant speed is called as synchronous speed.  And the motor which does not rotates at constant speed are called asynchronous motor. Asynchronous motor is also called as Induction motor.

Show More

143 views 1 answer








Last Answer : In a A.C. series motor armature coils are usually connected to commutator through resistance.

Show More

161 views 1 answer







Why does the speed of a DC shunt motor decrease as the load increases?
Last Answer : Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.

Show More

2.7k views 1 answer







The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α
Last Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Show More

150 views 1 answer






Show More⇦ PreviousNext ⇨