The ratio of starting torque to full-load torque is least in case of shunt motors.

Like 0 like

It is in order
Diff compound ,shunt, cumulative,series

Please log in or register to answer this question.

Related Questions



Last Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

Show More

164 views 1 answer







In a double squirrel cage induction motor, good starting torque is produced as (A) Large current flows through the outer high resistance winding. (B) Large current flows through the inner high ... the outer high resistance winding. (D) Large current flows through the inner low resistance winding.
Last Answer : In a double squirrel cage induction motor, good starting torque is produced as Large current flows through the outer high resistance winding.

Show More

136 views 1 answer








Last Answer : Buses, trains, trolleys, hoists, cranes require high starting torque and therefore make use of D.C. series motor.

Show More

117 views 1 answer








Last Answer : Capacitor start motor has high torque in starting

Show More

133 views 1 answer







The ratio of full -load volt-amperes to short-circuit volt-amperes is equal to :
Last Answer : The ratio of full -load volt-amperes to short-circuit volt-amperes is equal to : Z (p.u)

Show More

153 views 1 answer







Why a dc series motor has a high starting torque?
Last Answer : motor

Show More

86 views 1 answer







Why high starting torque is required?

Show More

64 views 0 answers







Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be
Last Answer : Torque developed by a three-phase, 400V, induction motor is 100 N -m. If the applied voltage is reduced to 200-V, the d'veloped torque will be 25 N -m

Show More

422 views 1 answer







Torque angle for the synchronous machine is the angle between (A) stator magnetic field and rotor magnetic field (B) stator magnetic field and net magnetic field in the air gap (C) rotor magnetic field and net magnetic field in the air gap (D) excitation voltage and impedance voltage drop
Last Answer : Torque angle for the synchronous machine is the angle between rotor magnetic field and net magnetic field in the air gap

Show More

128 views 1 answer







The torque developed by any 3-phase induction motor at 0.8 p.u. slip is (A) Full-load torque (B) unstable torque (C) starting torque (D) break down
Last Answer : The torque developed by any 3-phase induction motor at 0.8 p.u. slip is unstable torque

Show More

3.1k views 1 answer








Last Answer : The armature torque of the D.C. shunt motor is proportional to armature current.

Show More

210 views 1 answer








Last Answer : Speed torque characteristic of a repulsion induction motor is similar to that of a D.C. compound motor.

Show More

164 views 1 answer








Last Answer : In repulsion motor, maximum torque is developed when brush axis is at 45° electrical to the field axis.

Show More

115 views 1 answer







What is the formula of torque?

Show More

84 views 0 answers







At full -load of a transformer, the iron loss and copper loss are 3000 W and 4000 W respectively. Then total loss at maximum efficiency is :  (A) 7000 W (B) 6000 W (C) 8000 W (D) 4000 W
Last Answer : At full -load of a transformer, the iron loss and copper loss are 3000 W and 4000 W respectively. Then total loss at maximum efficiency is : 6000 W

Show More

301 views 1 answer








Last Answer : The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

Show More

98 views 1 answer








Last Answer : The starting resistance of a D.C. motor is generally low.

Show More

169 views 1 answer








Last Answer : A direct online starter is used for starting motors up to 5 H.P.

Show More

82 views 1 answer








Last Answer : For starting a D.C. motor a starter is required because it limits the starting current to a safe value.

Show More

123 views 1 answer








Last Answer : The starting winding of a single-phase motor is placed in stator.

Show More

114 views 1 answer








Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Show More

234 views 1 answer








Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Show More

215 views 1 answer







How is a three phase cage induction motor self starting?
Last Answer : Any type of induction motor is self starting. Because the reason for torqe production require two flux displaced by some angle theta.If theta is constant with time then torqe will be constant;if ... torqe also pulsating. In induction motor this angle theta is not pulsating.so it is self starting 

Show More

155 views 1 answer







Is induction motor is self starting?
Last Answer : Single phase induction motor is not self starting. Three phase induction motor is self starting.

Show More

111 views 1 answer














Last Answer : The mechanical power developed by a shunt motor will be maximum when the ratio of back e.m.f. to applied voltage is 0.5.

Show More

324 views 1 answer







The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?
Last Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

Show More

302 views 1 answer







DC motor gross torque example
Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Show More

145 views 2 answers







Describe spring control method of producing controlling torque in measuring instrument. Write any two properties required for spring material.
Last Answer : A)Spring control method: As shown in the figure, the inner ends of the both springs are attahced to the spindle, while outer end of upper spring is attached to the lever and outer ... of spring material: 1.Non Magnetic material 2.Low specific resistance 3.Low temperature coefficient of resistance

Show More

816 views 1 answer







Name the different torque and their function in measuring instrument.
Last Answer : List of torques in analog instruments:  1. Deflecting torque  2. Controlling / restraining torque.  3. Damping torque.  1. Deflecting torque:  - To create deflection of pointer ... .  - Bring the pointer to standstill quickly.  - To minimize oscillations about final position. 

Show More

454 views 1 answer







State the function of controlling torque in electrical measuring instrument.
Last Answer : Function of controlling torque  1. The function is to opposes the deflection force and increases with the increase in the deflection of the moving system, to limit its movement. 2. and brought ... set a position where the two opposing forces i.e. deflection and controlling forces are equal. 

Show More

217 views 1 answer







List the different methods to produce damping torque.
Last Answer : Methods of providing damping torque in indicating type instruments: 1) Air friction damping. 2) Fluid friction damping. 3) Eddy current damping.

Show More

140 views 1 answer







State the function of controlling torque. Write two types of it.
Last Answer : Function of Controlling Torque:  To restrict the motion of pointer / spindle and stop the pointer at the relevant position to get correct reading.  To bring back pointer to zero ... measurement is removed.  Types of Controlling Torque: 1. Spring control method 2.Gravity control method 

Show More

314 views 1 answer







Ideally, the damping torque should be  (1) Proportional to velocity of the moving system and operating current.  (2) Proportional to the velocity of the moving system but independent of operating ... operating current.  (4) Independent of the velocity of the moving system and operating current.
Last Answer : Ideally, the damping torque should be Proportional to the velocity of the moving system but independent of operating current. 

Show More

679 views 1 answer







The meter which does not have any component in it to provide control torque is (A) Electrodynamometer for current measurement (B) Electrodynamometer for voltage measurement (C) Electrodynamometer for power measurement. (D) Electrodynamometer for power factor measurement.
Last Answer : The meter which does not have any component in it to provide control torque is Electrodynamometer for power factor measurement.

Show More

157 views 1 answer







The torque produced in wattmeter is proportional to
Last Answer : A

Show More

1.2k views 2 answers







The shaft torque of a d.c. motor is less than its armature torque because of .......... losses.
Last Answer : The shaft torque of a d.c. motor is less than its armature torque because of rotational losses.

Show More

5.6k views 1 answer







The maximum torque of d.c. motors is limited by?
Last Answer : The maximum torque of d.c. motors is limited by commutation.

Show More

820 views 1 answer








Last Answer : In a meggar controlling torque is provided by coil.

Show More

573 views 1 answer








Last Answer : In a portable instrument, the controlling torque is provided by spring.

Show More

181 views 1 answer








Last Answer : Torque developed by a D.C. motor depends upon magnetic field, active length of the conductor, current flow through the conductors, number of conductors, radius of armature.

Show More

637 views 1 answer








Last Answer : For constant torque drive armature voltage control speed control method is preferred.

Show More

176 views 1 answer








Last Answer : A synchronous motor can develop synchronous torque at synchronous speed.

Show More

114 views 1 answer







The maximum torque which a synchronous motor will develop at rest for any angular position of the rotor, at rated stator supply voltage and frequency, is known as?

Show More

106 views 0 answers








Last Answer : The torque produced in induction type relay (shaded pole structure) is inversely proportional to the square of the current.

Show More

829 views 1 answer







What is the maximum value of torque angle in synchronous motor?
Last Answer : The maximum value of torque angle in synchronous motor is 90 degrees electrical.

Show More

1.5k views 1 answer







List different starting methods of three phase synchronous motor. Explain any one of them.
Last Answer : Different Starting Methods of Three Phase Synchronous Motor: As synchronous motor is not self starting, different methods of starting are as follows: 1) By using an Induction (Pony) motor 2) ... . The rotor gets pulled into synchronism and starts running at constant speed as a synchronous motor. 

Show More

156 views 1 answer







Explain starting system in diesel electric power plant.
Last Answer : Starting system in Diesel Electric Power Plant: It includes Storage battery, compressed air tanks, self-starter etc. The purpose of engine starting system is to rotate the engine initially while ... as Ammeters, Voltmeters, Wattmeters, Thermometers, Pressure gauges, Visible and audible alarm etc.

Show More

125 views 1 answer







State the functions of following elements: i) Diesel engine system ii) Air intake system iii) Engine exhaust system iv) Engine starting system.
Last Answer : i) Diesel engine system:-  Four strokes Two strokes ii) Air intake system:- Air intake system is provided to supply air to engine cylinder for fuel combustion.  iii) Engine exhaust system ... provided to rotate the engine initially until the firing starts and engine run under its own power. 

Show More

92 views 1 answer







In a 741 Op-Amp, there is 20 dB/decade fall-off starting at a relatively low frequency. This is due to the (A) applied load (B) internal compensation (C) impedance of the source (D) power dissipation in the chip
Last Answer : In a 741 Op-Amp, there is 20 dB/decade fall-off starting at a relatively low frequency. This is due to the internal compensation

Show More

162 views 1 answer






Show More⇦ PreviousNext ⇨