D.C. generators are normally designed for maximum efficiency around full-load.

Like 0 like

Please log in or register to answer this question.

Related Questions



Last Answer : Generators for peak load plants are usually designed for maximum efficiency at 50 to 75 percent full load.

Show More

139 views 1 answer








Last Answer : The condition for maximum efficiency for a D.C. generator is variable losses equal to constant losses.

Show More

237 views 1 answer








Last Answer : The efficiency of a properly designed synchronous motor will usually fall in range 85 to 95%.

Show More

73 views 1 answer








Last Answer : If  equalising bar is connected to the 2 DC generators  the current will be equal in 2 generators irrespective of parallel connection so that we connect equaliser bar

Show More

165 views 2 answers








Last Answer : In D.C. generators the polarity of the interpoles is the same as that of the main pole ahead.

Show More

138 views 1 answer








Last Answer : For the parallel operation of two or more D.C. compound generators, we should ensure that series fields of all generators should be either on positive side or negative side of the armature.

Show More

179 views 1 answer








Last Answer : Compensating windings are used in D.C. generators to neutralise the cross-magnetising effect of the armature reaction.

Show More

151 views 1 answer








Last Answer : D.C. generators are connected to the busbars or disconnected from them only under the floating condition to avoid sudden loading of the primemover, to avoid mechanicaljerk to the shaft, to avoid burning of switch contacts.

Show More

94 views 1 answer








Last Answer : In D.C. generators, the brushes on commutator remain in contact with conductors which lie under interpolar region.

Show More

223 views 1 answer








Last Answer : In D.C. generators, current to the external circuit from armature is given through commutator commutator.

Show More

253 views 1 answer








Last Answer : In D.C. generators the pole shoes are fastened to the pole core by counter sunk screws.

Show More

209 views 1 answer








Last Answer : D.C. generators are installed near the load centres to reduce line losses.

Show More

154 views 1 answer








Last Answer : An ideal transformer will have maximum efficiency at a load such that copper loss equal to iron loss.

Show More

204 views 1 answer







For a transformer, operating at constant load current, maximum efficiency will occur at?
Last Answer : For a transformer, operating at constant load current, maximum efficiency will occur at unity power factor.

Show More

124 views 1 answer








Last Answer : Transformer efficiency is maximum when copper losses are equal to iron losses.

Show More

91 views 1 answer







DC GENERATORS MCQ
Last Answer : 101. Wave winding is composed of (a) any even number of conductors (b) any odd number of conductors (c) that even number which is exact multiple of poles + 2 (d) that even number ... increase the field resistance (c) increase the speed of primemover (d) check armature insulation resis¬tance Ans: a

Show More

110 views 3 answers







Identify the increasing order of voltage regulation of the following dc generators a same load :  (A) differential compound, shunt and under compound  (B) shunt, differential compound and ... C) under compound, shunt and differential compound  (D) shunt, under compound and differential compound
Last Answer : Identify the increasing order of voltage regulation of the following dc generators a same load : under compound, shunt and differential compound 

Show More

123 views 1 answer







In DC generators lamination core are generally made of?
Last Answer : In DC generators lamination core are generally made of silicon steel.

Show More

256 views 1 answer







State maximum power transfer theorem for DC circuit.
Last Answer : Maximum power transfer theorem for DC circuit: The maximum power transfer theorem states that the source or a network transfers maximum power to load only when the load resistance is equal ... removed (disconnected) ii) All internal independent sources are replaced by their internal resistances.

Show More

110 views 1 answer








Last Answer : Series motor has got maximum self relieving property.

Show More

193 views 1 answer








Last Answer : (b) Clostridium butylicum Lipase Removal of oil stains

Show More

107 views 1 answer








Last Answer : In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.

Show More

367 views 1 answer







The field coils of D.C. generator are usually made of (a) mica (b) copper (c) cast iron (d) carbon
Last Answer : Ans: b (b) copper

Show More

33 views 1 answer







The resistance of armature winding depends on (a) length of conductor (b) cross-sectional area of the conductor (c) number of conductors (d) all of the above

Show More

6 views 0 answers







The armature of D.C. generator is laminated to (a) reduce the bulk (b) provide the bulk (c) insulate the core (d) reduce eddy current loss

Show More

15 views 0 answers







Which of the following could be lamina-proximately the thickness of laminations of a D.C. machine ? (a) 0.005 mm (b) 0.05 mm (c) 0.5 m (d) 5 m

Show More

6 views 0 answers







Laminations of core are generally made of (a) case iron (b) carbon (c) silicon steel (d) stainless steel

Show More

3 views 0 answers







Phase modifier is normally installed
Last Answer : Phase modifier is normally installed in case of long lines

Show More

337 views 1 answer







If the load of the normally excited synchronous motor is increased the power factor will?
Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Show More

150 views 1 answer







Explain the lighting scheme to be designed for each of the following: i) Special ward in hospitals ii) Dentist’s Cabin 
Last Answer : i) Special ward in hospital: For the patients in the wards, lighting should create a cozy and pleasant atmosphere. Lighting in the wards should be planned in such a way that it meets the specific ... we use such as cements and bonding agents that we use to restore your teeth back to health.

Show More

190 views 1 answer







A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above
Last Answer : A circuit breaker is designed to protect an electrical circuit from damage caused by :  (A) Over load (B) Short circuit (C) Over current (D) All of the above

Show More

106 views 1 answer







What would happen if a power transformer designed for operation on 50 Hz (frequency) were connected to a 500 Hz (frequency) source of the same voltage:  (A) Eddy Current and Hysteresis losses will be ... Current will be too much high  (C) Transformer may start to smoke and burn  (D) No effect
Last Answer : What would happen if a power transformer designed for operation on 50 Hz (frequency) were connected to a 500 Hz (frequency) source of the same voltage:  (A) Eddy Current and Hysteresis losses will be ... will be too much high  (C) Transformer may start to smoke and burn  (D) No effect

Show More

795 views 1 answer








Last Answer : Overhead system can be designed for operation up to 400 kV.

Show More

210 views 1 answer








Last Answer : Air blast circuit breakers for 400 kV power system are designed to operate in 50 millisecond.

Show More

209 views 1 answer








Last Answer : An efficient and a well designed protective relaying should have good selectivity and reliability, economy and simplicity, high speed and selectivity.

Show More

136 views 1 answer








Last Answer : Relays can be designed to respond to changes in resistance, reactance or impedance voltage and current, light intensity, temperature.

Show More

145 views 1 answer








Last Answer : In D.C. generators on no-load, the air gap flux distribution in space is flat topped.

Show More

144 views 1 answer







How Generators Work
Last Answer : How Generators Work Generators are devices which produce electricity. They produce electricity by converting mechanical energy from power sources. Examples would be steam, water, wind and gasoline. These ... can also be used for recreational purposes. Examples would be camping, boating or fishing.

Show More

6 views 1 answer







Why are generators rated in kVA not in kW ?
Last Answer : Because It's rating of generator kva is apparent power. Kw is active power which we use. And one is kvar reactive power.

Show More

117 views 3 answers







Two synchronous generators G1, G2 are operating in parallel and are equally sharing KVAR (Lag) component of load. To shift part of KVAR from G2 to G1, while keeping terminal voltage fixed, the following action must be done
Last Answer : Two synchronous generators G1, G2 are operating in parallel and are equally sharing KVAR (Lag) component of load. To shift part of KVAR from G2 to G1, while keeping terminal voltage fixed, the following action must be done Raise If1 and lower If2

Show More

421 views 1 answer







Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, ... system frequency is (A) 50 Hz (B) 51 Hz (C) 51.25 Hz (D) 51.5 Hz
Last Answer : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, respectively. Then the system frequency is 50 Hz

Show More

114 views 1 answer








Last Answer : Large capacity generators are invariably hydrogen cooled.

Show More

95 views 1 answer








Last Answer : The total losses in a well designed D.C. generator of 10 kW will be nearly 500 W.

Show More

138 views 1 answer








Last Answer : The overall efficiency of steam locomotive is around 5 to 10 percent.

Show More

96 views 1 answer







Define : i) Maximum Value ii) RMS Value of ac supply
Last Answer : i) Maximum Value :- The maximum or peak value attained by an alternating quantity during positive or negative half cycle, is called maximum value or peak value.  ii) RMS Value of ac ... as produced by the alternating current when flowing through the same resistance and for the same time. 

Show More

85 views 1 answer







Define the following terms: 1) Virtual height 2) Actual height 3) Critical frequency. 4) Maximum usable frequency.
Last Answer : 1) Virtual height:- The incident and refracted rays follow paths that are exactly the same as they have been if reflection had taken place from a surface located at a greater height, called ... angle of incidence is other than the normal is known as maximum unstable frequency. MUF= fc secθ 

Show More

82 views 1 answer







Maximum Power Transfer Theorem 1
Last Answer : Maximum Power Transfer Theorem 1

Show More

93 views 1 answer







 An independent voltage source in series with an impedance ZS=R+jXS delivers a maximum average power to a load impedance ZL when A) ZL = R B) ZL = jXS C) ZL = R-jXS D) ZL = R+jXS 
Last Answer :  An independent voltage source in series with an impedance ZS=R+jXS delivers a maximum average power to a load impedance ZL when ZL = R-jXS

Show More

4.0k views 1 answer







A certain power MOSFET has a maximum junction temperature specification of 1500o C, a junction-to-case thermal resistance of 1.00 C/W, and a junction-to ambient thermal resistance of 600 C/W. If the ambient temperature is 300o C ... the device will be A) 1.52 W B) 1.72 W C) 1.92W D) 2.00 W
Last Answer : A certain power MOSFET has a maximum junction temperature specification of 1500o C, a junction-to-case thermal resistance of 1.00 C/W, and a junction-to ambient thermal resistance of  ... 300o C, then the maximum allowable power dissipation in the device will be 2.00 W 

Show More

148 views 1 answer







The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu
Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

Show More

98 views 1 answer






Show More⇦ PreviousNext ⇨