Please Log in or Register for more.


112 views

1 Answer

Answer :

Copper brushes in D.C. machine are used where low voltage and high currents are involved.

Like 0 like

Please log in or register to answer this question.

Related Questions



Last Answer : The rapid wear of brushes takes place due to abrasion from dust, excessive spring pressure, rough commutator bars, high mica insulation between com-mutation bars.

Show More

81 views 1 answer








Last Answer : Armature coil is short circuited by brushes when it lies along neutral axis.

Show More

187 views 1 answer








Last Answer : The number of brushes in a commutator depends on amount of current to be collected.

Show More

158 views 1 answer








Last Answer : The material for commutator brushes is generally carbon.

Show More

151 views 1 answer








Last Answer : Brushes of D.C. machines are made of carbon.

Show More

87 views 1 answer








Last Answer : In lap winding, the number of brushes is always same as the number of poles.

Show More

323 views 1 answer







Brushes of DC machine are made up of ?
Last Answer : Brushes of DC machine are made up of carbon.

Show More

165 views 1 answer







In a DC motor, it is important to place the brushes along ______ A) Magnetic Neutral Axis B) Normal Geometric Axis C) Nominal Geometric Axis D) None of these
Last Answer : In a DC motor, it is important to place the brushes along Magnetic Neutral Axis

Show More

96 views 1 answer







How to Solder Copper Pipe
Last Answer : How to Solder Copper Pipe Copper tubing or pipes work well for air, water or even refrigerants. If you want to join them together with sweat joints , you'll have to learn how to solder them ... effect on their efficiency. Follow these steps and be able to do copper pipe soldering all by yourself.

Show More

8 views 1 answer







How to Patina Copper
Last Answer : How to Patina Copper Patina is that tarnish coating that develops outside metal, like copper, over time. Not only does it add an attractive appearance to copper, but it also provides protection to harsh ... egg. Once you've reached the desired patina coat, rinse the copper pieces in lukewarm water.

Show More

4 views 1 answer







How to Clean Copper
Last Answer : How to Clean Copper Whether it's a coin, a pan, or a trophy, copper has one of the nicest-looking finishes among common metals. Copper can retain its finish for quite a while, although it is ... properly. With these tips, you'll never have to worry about your copper items losing their shine again.

Show More

3 views 1 answer







Select insulating materials for following parts : (i) Insulation between heating element and base plate of electric iron. (ii) Insulation used over copper or aluminium conductor used for making coils. (iii) Transformer bushings. (iv) Insulation between transmission line and pole.
Last Answer : Parts Insulating Materials  Insulation between heating element and base plate of electric iron. Mica Insulation used over copper or aluminium conductor used for making coils.  ... Transformer bushings Porcelain  Insulation between transmission line and pole. Porcelain

Show More

199 views 1 answer







Why is aluminium used instead of copper for overhead cables?
Last Answer : Because copper reacts with atmosphere variation and it's cost High as compared to aluminium and aluminium is good property and less cost so aluminium is used

Show More

138 views 6 answers







Which is a semiconductor: copper, silicon, or neon?
Last Answer : Copper is a metal. Silicon is a semiconductor. Neon is inert gas.

Show More

2.8k views 1 answer







Compare copper and aluminium.
Last Answer : Copper Aluminium Resistivity is less Resistivity is more More weight Low weight Mechanically strong Mechanically weaker Specific Gravity high Specific Gravity Low ... Tensile strength is half of that of copper Used for winding Used for overhead lines

Show More

75 views 1 answer







A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is
Last Answer : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is 0.707

Show More

774 views 1 answer







At full -load of a transformer, the iron loss and copper loss are 3000 W and 4000 W respectively. Then total loss at maximum efficiency is :  (A) 7000 W (B) 6000 W (C) 8000 W (D) 4000 W
Last Answer : At full -load of a transformer, the iron loss and copper loss are 3000 W and 4000 W respectively. Then total loss at maximum efficiency is : 6000 W

Show More

303 views 1 answer







Two copper conductors have equal length. The cross-sectional area of one conductor is four times that of the other. If the conductor having smaller cross-sectional area has a resistance of 40 ohms the resistance of other conductor will be?
Last Answer : Two copper conductors have equal length. The cross-sectional area of one conductor is four times that of the other. If the conductor having smaller cross-sectional area has a resistance of 40 ohms the resistance of other conductor will be 10 ohms.

Show More

318 views 1 answer







Current velocity through a copper conductor is

Show More

121 views 0 answers








Last Answer : The ground wire should not be smaller than No 10 copper.

Show More

157 views 1 answer







Auto-transformer makes effective saving on copper and copper losses, when its transformation ratio is?
Last Answer : Auto-transformer makes effective saving on copper and copper losses, when its transformation ratio is approximately equal to 1.

Show More

160 views 1 answer







How do magnets and copper wire make electricity?
Last Answer : According  to  Faradays  law , a changing  magnetic  field  on  a  conductor  induses  current  in  the  conductor  through   mutual  induction.

Show More

162 views 1 answer







explain skin effect in copper interconnects. what are the various ways of reducing this effect?
Last Answer : Skin effect generally observed in ac conductor in transmission network, in skin the current flowing through outer layer of conductor is more than iner area of conductor thus we can say the ... for reducing this effect we can use boundel conductor or used hollow conductor for power transmission

Show More

100 views 1 answer







In a DC shunt generator working on load, the brushes are moved forward in the direction of rotation, as a result of this, commutation will   (a) Improve but terminal voltage will fall   (b) ... will fall   (c) Improve and terminal voltage will rise   (d) worsen and terminal voltage will rise 
Last Answer : In a DC shunt generator working on load, the brushes are moved forward in the direction of rotation, as a result of this, commutation will Improve but terminal voltage will fall 

Show More

421 views 1 answer








Last Answer : If brushes of a D.C. generator are moved in order to bring these brushes in magnetic neutral axis, there will be crossmagnetisation as well as demagnetising.

Show More

148 views 1 answer








Last Answer : In D.C. generators, the brushes on commutator remain in contact with conductors which lie under interpolar region.

Show More

223 views 1 answer







Copper brushes in D.C. machine are used (a) where low voltage and high currents are involved (b) where high voltage and small cur-rents are involved (c) in both of the above cases (d) in none of the above cases
Last Answer : Ans: a

Show More

13 views 1 answer







Etched or burned bands on the contact faces of the brushes in a direct current generator can be caused by ____________. A. high mica segments B. copper drag on the commutator C. brushes improperly positioned D. copper embedded in the brushes
Last Answer : Answer: C

Show More

0 views 1 answer







The material for commutator brushes is generally (a) mica (b) copper (c) cast iron (d) carbon
Last Answer : Ans: d

Show More

28 views 1 answer







Brushes of D.C. machines are made of (a) carbon (b) soft copper (c) hard copper (d) all of above
Last Answer : Ans: a

Show More

28 views 1 answer








Last Answer : In a D.C. machine stray loss is the sum of iron loss and mechanical loss.

Show More

218 views 1 answer








Last Answer : In any rotating machine that part which houses the conductors and in which e.m.f. induced is to be utilised is called armature.

Show More

193 views 1 answer








Last Answer : To avoid formation of grooves in the commutator of a D.C. machine the brushes of opposite polarity should track each other.

Show More

3.0k views 1 answer








Last Answer : Open circuited armature coil of a D.C. machine is identified by the scarring of the commutator segment to which open circuited coil is connected and indicated by a spark completely around the commutator.

Show More

159 views 1 answer








Last Answer : In case of D.C. machine winding, number of commutator segments is equal to number of armature coils.

Show More

665 views 1 answer













Eddy currents are induced in the pole shoes of a D.C. machine due to?
Last Answer : Eddy currents are induced in the pole shoes of a D.C. machine due to relative rotation between field and armature.

Show More

231 views 1 answer








Last Answer : Armature reaction of an unsaturated D.C. machine is crossmagnetising.

Show More

353 views 1 answer








Last Answer : Iron losses in a D.C. machine are independent of variations in load.

Show More

161 views 1 answer








Last Answer : In a four-pole D.C. machine alternate poles are north and south.

Show More

81 views 1 answer







Seating the brushes on a D.C. motor is first accomplished using ________________. A. a file for cutting the approximate curvature followed by sandpaper for the final fit B. sandpaper with the motor not ... for the finishing cut D. course lapping compound, followed by a medium and then a fine grade
Last Answer : Answer: B

Show More

2 views 1 answer







Voltage generated by most AC generators is fed from the machine to the bus by means of ____________. A. brushes on a commutator B. brushes on slip rings C. slip rings on a commutator D. direct connections from the stator
Last Answer : Answer: D

Show More

0 views 1 answer







In a d.c. machine, the armature mmf is (A) stationary w.r.t. armature. (B) rotating w.r.t. field. (C) stationary w.r.t. field. (D) rotating w.r.t. brushes.
Last Answer : (C) stationary w.r.t. field.

Show More

7 views 1 answer







The number of brushes in a 6-pole double-layer lap wound dc machine is (A) 8 (B) 6 (C) 4 (D) 2 

Show More

154 views 0 answers







If we have 30kva, 250 kva, 300kva d.g set than how many earthing we do? 
Last Answer : We should have two distinct earthing for neautral earthing and two for Body earthing.To achieve minimal resistance neautral earthpit should be connected in parallel.similarly body earthing too.

Show More

209 views 2 answers







If a self excited d.c. generator after being installed, fails to build up voltage on its first trial run, the first thing to do is (a) reverse the field winding connections (b) increase the field resistance (c) decrease the speed of prime mover (d) increase the speed of prime mover  

Show More

154 views 0 answers







A cumulatively compounded d.c. generator is supplying 20 A at 200 V. If the series field winding is short circuited, the terminal voltage will (a) remain unaltered (b) rise to 220 V (c) shoot up to a very high value (d) become less than 200 V 

Show More

126 views 0 answers







A 8-pole, DC generator has a simplex wave-wound armature containing 32 coils of 6 turns each. Its flux per pole is 0.06 Wb. The machine is running at 250 rpm. The induced armature voltage is  (A) 96 V (B) 192 V (C) 384 V (D) 768 V
Last Answer : A 8-pole, DC generator has a simplex wave-wound armature containing 32 coils of 6 turns each. Its flux per pole is 0.06 Wb. The machine is running at 250 rpm. The induced armature voltage is 384 V

Show More

757 views 1 answer







The voltage built-up process of a d.c. generator is  1. difficult 2. delayed 3. cumulative 4. Infinite 
Last Answer : The voltage built-up process of a d.c. generator is cumulative 

Show More

2.5k views 1 answer







for the voltage built-up a self-excited D.C. generator, which of the following is not an essential condition.  1.there must be some residual flux  2.field winding mmf must aid the residual ... 3.total field circuit resistance must be less than t critical value  4.armature speed must be very high
Last Answer : for the voltage built-up a self-excited D.C. generator, which of the following is not an essential condition.  1.there must be some residual flux  2.field winding mmf must aid the ... .total field circuit resistance must be less than t critical value  4.armature speed must be very high

Show More

659 views 1 answer






Show More⇦ PreviousNext ⇨