In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be 8.

Like 0 like

Please log in or register to answer this question.

Related Questions



Last Answer : In a D.C. generator in case the resistance of the field winding is increased, then output voltage will decrease.

Show More

251 views 1 answer








Last Answer : The critical resistance of the D.C. generator is the resistance of field.

Show More

554 views 1 answer







If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be?
Last Answer : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be zero.

Show More

277 views 1 answer








Last Answer : A 220 V D.C. generator is run at full speed without any excitation. The open circuit voltage will be about 2 V.

Show More

483 views 1 answer








Last Answer : In a level compounded D.C. generator, full load terminal voltage is equal to no-load terminal voltage.

Show More

129 views 1 answer








Last Answer : A D.C. generator can be considered as rotating amplifier.

Show More

73 views 1 answer








Last Answer : In a D.C. generator, the critical resistance refers to the resistance of field.

Show More

136 views 1 answer








Last Answer : Flashing the field of D.C. generator means creating residual magnetism by a D.C. source.

Show More

95 views 1 answer








Last Answer : If a D.C. generator fails to build up the probable cause could not be field resistance less than the critical resistance.

Show More

128 views 1 answer








Last Answer : In a D.C. generator the magnetic neutral axis coincides with the geometrical neutral axis, when there is no load on|he generator.

Show More

226 views 1 answer








Last Answer : The e.m.f. generated in a D.C. generator is directly proportional to speed of armature.

Show More

600 views 1 answer








Last Answer : In a D.C. generator the number of mechanical degrees and electrical degrees will be the same when number of poles is 2.

Show More

785 views 1 answer








Last Answer : D.C. generator generally preferred for charging automobile batteries is long shunt compound generator.

Show More

239 views 1 answer








Last Answer : The armature core of a D.C. generator is usually made of silicon steel.

Show More

151 views 1 answer














Last Answer : In a D.C. generator the ripples in the direct e.m.f. generated are reduced by using carbon brushes of superior quality.

Show More

224 views 1 answer







430 views 2 answers








Last Answer : The demagnetising component of armature reaction in a D.C. generator reduces generator e.m.f.

Show More

121 views 1 answer








Last Answer : If brushes of a D.C. generator are moved in order to bring these brushes in magnetic neutral axis, there will be crossmagnetisation as well as demagnetising.

Show More

148 views 1 answer







For a D.C. generator when the number of poles and the number of armature conductors is fixed, then which winding will give the higher e.m.f. ?
Last Answer : Wave winding

Show More

141 views 1 answer














Last Answer : In a D.C. generator, the iron losses mainly take place in armature rotor.

Show More

273 views 1 answer








Last Answer : The condition for maximum efficiency for a D.C. generator is variable losses equal to constant losses.

Show More

237 views 1 answer








Last Answer : The total losses in a well designed D.C. generator of 10 kW will be nearly 500 W.

Show More

138 views 1 answer







From which material field coils of DC generator are made of?
Last Answer : Field coils of DC generator are usually made of copper.

Show More

118 views 1 answer







A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively
Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Show More

588 views 1 answer








Last Answer : In D.C. generators on no-load, the air gap flux distribution in space is flat topped.

Show More

144 views 1 answer







The purpose of providing dummy coils in a generator is?
Last Answer : The purpose of providing dummy coils in a generator is to provide mechanical balance for the rotor.

Show More

312 views 1 answer







State the function of commutator in DC generator and name the material used for commutator.
Last Answer : Function of Commutator: Commutator converts AC induced in armature winding into DC for external load. Material: i) Commutator segments are made up of Copper. ii) Commutator segments are insulated from each other by Mica.

Show More

256 views 1 answer







A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is
Last Answer : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is 0.87

Show More

127 views 1 answer







The fall in speed of a dc generator due to increase in load can be corrected by  (1) cooling the armature.. (2) increasing the excitation. (3) reducing the load voltage. (4) increasing the input to the prime mover
Last Answer : It   can  be  corrected  by  increasing  the  input  to  the  prime  mover.

Show More

355 views 2 answers







The eddy current loss in a dc generator is 400 W at 40 Hz frequency of reversal and constant flux density. When frequency is increased to 50 Hz., eddy current loss is :  (A) 256 W (B) 320 W (C) 500 W (D) 625 W
Last Answer : The eddy current loss in a dc generator is 400 W at 40 Hz frequency of reversal and constant flux density. When frequency is increased to 50 Hz., eddy current loss is : 625 W

Show More

103 views 1 answer







In a DC generator the windings of interpoles are connected :  (A) in series with main field winding, to create a pole,of same polarity as the main pole ahead in the direction of rotation.  ... winding, to create a pole of opposite polarity as the main pole ahead in the direction of rotation.
Last Answer : In a DC generator the windings of interpoles are connected :  in series with the armature winding, to create a pole of same polarity as the main pole ahead in the direction of rotation. 

Show More

122 views 1 answer







The terminal characteristics of a dc generator suitable for electric welders is (A) separately excited generator (B) shunt generator (C) series generator (D) differentially compounded generator
Last Answer : The terminal characteristics of a dc generator suitable for electric welders is differentially compounded generator

Show More

105 views 1 answer







What is the difference between an AC and DC generator?
Last Answer : The generator which generates DC voltage is called DC generator and generator which generates AC voltage is called AC generator (or) Alternator. In DC generator armature is rotated and field winding ... generator. A DC generator can generate low voltages but an AC generator can generate upto 11kv.

Show More

315 views 1 answer







What is the principle of DC generator?
Last Answer : principle

Show More

80 views 1 answer







Why is the armature of DC generator laminated?
Last Answer : The armature of DC generator is laminated to reduce eddy current losses.

Show More

176 views 1 answer








Last Answer : In case of a flat compounded generator voltage remains constant irrespective of the load.

Show More

103 views 1 answer








Last Answer : In the case of lap winding resultant pitch is difference of front and back pitches.

Show More

122 views 1 answer








Last Answer : In case of D.C. machine winding, number of commutator segments is equal to number of armature coils.

Show More

665 views 1 answer








Last Answer : Armature reaction in a generator results in demagnetisation of leading pole tip and magnetisation of trailing pole tip.

Show More

216 views 1 answer








Last Answer : In a separately excited generator supplying rated load the armature reaction is always present.

Show More

137 views 1 answer







A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave?
Last Answer : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave will be of 5 Hz.

Show More

177 views 1 answer








Last Answer : In over compounded generator, full load terminal voltage is more than no load terminal voltage.

Show More

114 views 1 answer








Last Answer : An exciter for a turbo generator is a shunt generator.

Show More

146 views 1 answer








Last Answer : A cumulatively compounded long shunt generator when operating as a motor would be differentially compounded long shunt.

Show More

111 views 1 answer







The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be?
Last Answer : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be 580 V.

Show More

668 views 1 answer







In a shunt generator the voltage build up is generally restricted by?

Show More

145 views 0 answers







A shunt generator running at 1000 r.p.m. has generated e.m.f. as 200 V. If the speed increases to 1200 r.p.m., the generated e.m.f. will be nearly?
Last Answer : 200V/E2 = 1000/1200 E2= 240 V