In case of D.C. machine winding, number of commutator segments is equal to number of armature coils.

Like 0 like

Please log in or register to answer this question.

Related Questions


A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively
Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Show More

588 views 1 answer







Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper
Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Show More

621 views 1 answer








Last Answer : To avoid formation of grooves in the commutator of a D.C. machine the brushes of opposite polarity should track each other.

Show More

3.0k views 1 answer








Last Answer : In a D.C. machine stray loss is the sum of iron loss and mechanical loss.

Show More

218 views 1 answer








Last Answer : Open circuited armature coil of a D.C. machine is identified by the scarring of the commutator segment to which open circuited coil is connected and indicated by a spark completely around the commutator.

Show More

158 views 1 answer














Last Answer : Iron losses in a D.C. machine are independent of variations in load.

Show More

161 views 1 answer








Last Answer : In a four-pole D.C. machine alternate poles are north and south.

Show More

81 views 1 answer







A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is
Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Show More

329 views 1 answer








Last Answer : In D.C. machines fractional pitch winding is used to reduce the sparking.

Show More

355 views 1 answer








Last Answer : In the case of lap winding resultant pitch is difference of front and back pitches.

Show More

122 views 1 answer








Last Answer : In lap winding, the number of brushes is always same as the number of poles.

Show More

322 views 1 answer







Why poles of dc machine are laminated?
Last Answer : Poles of DC machines are laminated to reduce the eddy current losses in the poles.

Show More

112 views 1 answer








Last Answer : Copper losses,iron losses,variable losses , constant losees

Show More

174 views 1 answer







Explain concept of back emf in DC machine. State how it governs armature current. 
Last Answer : Back emf: When the armature of DC machine rotates under the influence of driving torque, the armature conductors move in the magnetic field and cut it and hence emf is induced in them. The ... flow of armature current i.e. it automatically changes the armature current to meet load requirements.

Show More

189 views 1 answer







A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is
Last Answer : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is 0.87

Show More

127 views 1 answer







The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is  (1) 1000V (2) 100V (3) 600V (4) 10,000V
Last Answer : The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is 1000V

Show More

370 views 1 answer







In a dc machine, interpoles are used to  (1) neutralize the effect of armature reaction in the interpolar region (2) generate more induced emf in the armature (3) avoid interference of the armature flux with the main -field flux (4) reduce the demagnetizing effect of armature reaction
Last Answer : In a dc machine, interpoles are used to neutralize the effect of armature reaction in the interpolar region

Show More

175 views 1 answer







The magnetic neutral plane shifts in a dc machine (A) in the direction of motion of motor (B) in the direction of motion of generator (C) due to increase in the field flux (D) cause reduction of flash over between commutator segments
Last Answer : The magnetic neutral plane shifts in a dc machine in the direction of motion of generator

Show More

162 views 1 answer







What is the percentage of stray losses in DC machine?
Last Answer : Percentage of stray losses in DC machine is about 1 % .

Show More

115 views 1 answer







Brushes of DC machine are made up of ?
Last Answer : Brushes of DC machine are made up of carbon.

Show More

165 views 1 answer








Last Answer : Iron loss, copper loss and mechanical losses these are the losses in DC machine.

Show More

118 views 1 answer








Last Answer : Wave winding is composed of that even number which is exact multiple of poles + 2.

Show More

90 views 1 answer








Last Answer : Lap winding is composed of any even number of conductors.

Show More

129 views 1 answer








Last Answer : In D.C. generators, lap winding is used for low voltage, high current.

Show More

94 views 1 answer








Last Answer : The resistance of armature winding depends on length of conductor, cross-sectional area of the conductor, number of conductors.

Show More

212 views 1 answer








Last Answer : In a D.C. generator in case the resistance of the field winding is increased, then output voltage will decrease.

Show More

251 views 1 answer








Last Answer : In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be 8.

Show More

258 views 1 answer








Last Answer : In D.C. generators, the brushes on commutator remain in contact with conductors which lie under interpolar region.

Show More

223 views 1 answer








Last Answer : In any rotating machine that part which houses the conductors and in which e.m.f. induced is to be utilised is called armature.

Show More

193 views 1 answer







State the function of following parts of DC motor : i) Yoke ii) Poles iii) Field winding iv) Commutator. 
Last Answer : Function : i) Yoke: The yoke serves the following two purposes. i) It supports the other components such as poles and provides mechanical protection for whole machine. ii) It forms a part of ... one pole to another and thus to help the motor to develop a continuous and unidirectional torque  

Show More

533 views 1 answer








Last Answer : yes High Voltage side of Transformer winding have more number of turns. and low voltage side of Transformer winding have less number of turns.

Show More

156 views 1 answer







State advantages of short pitch winding over full pitch winding in alternators. 
Last Answer : Advantages of Short Pitch Winding over Full Pitch Winding in Alternators: 1) Short pitching reduces the amount of copper needed for end connection when compared with full pitched coil. 2) They ... reduced, thereby increasing the efficiency. 4) The power quality of generated emf is improved. 

Show More

478 views 1 answer








Last Answer : It is the wire wound around a aluminium metal it is found commonly in transformers or motors

Show More

106 views 1 answer







Damper winding in a synchronous motor
Last Answer : Damper winding in a synchronous motor Serves to start the motor.

Show More

87 views 1 answer







A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts
Last Answer : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Show More

223 views 1 answer







A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer
Last Answer : A Resistance thermometer is used to measure the stator % winding temperature of the generator. 

Show More

3.4k views 1 answer







Damper winding is provided in 3 phase synchronous motors to :
Last Answer : Damper winding is provided in 3 phase synchronous motors to : provide starting torque and prevent hunting

Show More

93 views 1 answer








Last Answer : The starting winding of a single-phase motor is placed in stator.

Show More

114 views 1 answer








Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Show More

234 views 1 answer








Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Show More

215 views 1 answer








Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Show More

222 views 1 answer








Last Answer : The purpose of stator winding in the compensated repulsion motor is to improve power factor and provide better speed regulation.

Show More

110 views 1 answer








Last Answer : In split phase motor main winding is of thick wire placed at the bottom of the slots.

Show More

83 views 1 answer








Last Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

Show More

145 views 1 answer








Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Show More

72 views 1 answer







The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?
Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Show More

116 views 1 answer








Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Show More

875 views 1 answer








Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Show More

207 views 1 answer








Last Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Show More

710 views 1 answer






Show More⇦ PreviousNext ⇨