A shunt generator running at 1000 r.p.m. has generated e.m.f. as 200 V. If the speed increases to 1200 r.p.m., the generated e.m.f. will be nearly?

2 Answers

Answer :

A shunt generator running at 1000 r.p.m. has generated e.m.f. as 200 V. If the speed increases to 1200 r.p.m., the generated e.m.f. will be nearly 240 V.

Answer :

200V/E2 = 1000/1200
E2= 240 V

Related questions

Description : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be?

Last Answer : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be 580 V.

Description : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave?

Last Answer : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave will be of 5 Hz.

Last Answer : A cumulatively compounded long shunt generator when operating as a motor would be differentially compounded long shunt.

Description : In a shunt generator the voltage build up is generally restricted by?

Last Answer : The e.m.f. generated in a D.C. generator is directly proportional to speed of armature.

Last Answer : In a D.C. generator the ripples in the direct e.m.f. generated are reduced by using carbon brushes of superior quality.

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be?

Last Answer : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be zero.

Description : A 4-pole, dc shunt motor working on 250V takes a current of 2A when running at no load on 1000 rpm. Calculate its back emf and speed at load if the motor takes 51A. Armature and shunt field resistance are 0.2Ω and 250Ω respectively

Last Answer : A 220 V D.C. generator is run at full speed without any excitation. The open circuit voltage will be about 2 V.

Last Answer : The purpose of retardation test on D.C. shunt machines is to find out stray losses.

Last Answer : If the speed of a D.C. shunt motor is increased, the back e.m.f. of the motor will increase.

Last Answer : In case of D.C. shunt motors the speed is dependent on back e.m.f. only because flux is practically constant in D:C. shunt motors.

Last Answer : The mechanical power developed by a shunt motor will be maximum when the ratio of back e.m.f. to applied voltage is 0.5.

Description : Why does the speed of a DC shunt motor decrease as the load increases?

Last Answer : Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Last Answer : The critical resistance of the D.C. generator is the resistance of field.

Last Answer : Armature reaction in a generator results in demagnetisation of leading pole tip and magnetisation of trailing pole tip.

Last Answer : In a separately excited generator supplying rated load the armature reaction is always present.

Last Answer : In a level compounded D.C. generator, full load terminal voltage is equal to no-load terminal voltage.

Last Answer : In over compounded generator, full load terminal voltage is more than no load terminal voltage.

Last Answer : In case of a flat compounded generator voltage remains constant irrespective of the load.

Last Answer : An exciter for a turbo generator is a shunt generator.

Last Answer : In a D.C. generator in case the resistance of the field winding is increased, then output voltage will decrease.

Last Answer : A D.C. generator can be considered as rotating amplifier.

Last Answer : In a D.C. generator, the critical resistance refers to the resistance of field.

Last Answer : Flashing the field of D.C. generator means creating residual magnetism by a D.C. source.

Last Answer : If a D.C. generator fails to build up the probable cause could not be field resistance less than the critical resistance.

Description : The purpose of providing dummy coils in a generator is?

Last Answer : The purpose of providing dummy coils in a generator is to provide mechanical balance for the rotor.

Last Answer : In a D.C. generator the magnetic neutral axis coincides with the geometrical neutral axis, when there is no load on|he generator.

Last Answer : In a D.C. generator the number of mechanical degrees and electrical degrees will be the same when number of poles is 2.

Last Answer : D.C. generator generally preferred for charging automobile batteries is long shunt compound generator.

Last Answer : The armature core of a D.C. generator is usually made of silicon steel.

Last Answer : The demagnetising component of armature reaction in a D.C. generator reduces generator e.m.f.

Last Answer : Welding generator will have lap winding.

Last Answer : If brushes of a D.C. generator are moved in order to bring these brushes in magnetic neutral axis, there will be crossmagnetisation as well as demagnetising.

Last Answer : In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be 8.

Last Answer : A separately excited generator as compared to a self-excited generator is amenable to better voltage control, more stable, has exciting current independent of load current.