1 Answer

Answer :

In over compounded generator, full load terminal voltage is more than no load terminal voltage.

Related questions

Last Answer : In a level compounded D.C. generator, full load terminal voltage is equal to no-load terminal voltage.

Last Answer : In case of a flat compounded generator voltage remains constant irrespective of the load.

Last Answer : A cumulatively compounded long shunt generator when operating as a motor would be differentially compounded long shunt.

Description : The terminal characteristics of a dc generator suitable for electric welders is (A) separately excited generator (B) shunt generator (C) series generator (D) differentially compounded generator

Last Answer : The terminal characteristics of a dc generator suitable for electric welders is differentially compounded generator

Description : State advantages of short pitch winding over full pitch winding in alternators. 

Last Answer : Advantages of Short Pitch Winding over Full Pitch Winding in Alternators: 1) Short pitching reduces the amount of copper needed for end connection when compared with full pitched coil. 2) They ... reduced, thereby increasing the efficiency. 4) The power quality of generated emf is improved. 

Description : What is internal voltage drop and terminal voltage?

Last Answer : It is not permissible to just connect the positive terminal to the negative terminal of a cell with a copper wire. It will overheat and get damaged. This happens because the electromotive force (emf) ... than the nominal voltage (emf) of the cell and this lower voltage is called terminal voltage.

Description : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is

Last Answer : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is 0.707

Description : A transformer operates 24 hours day at full -load. It's full -load efficiency is :  (A) equal all day efficiency (B) more than all -day efficiency (C) less than all -day efficiency (D) equal to maximum efficiency

Last Answer : A transformer operates 24 hours day at full -load. It's full -load efficiency is : equal all day efficiency 

Last Answer : If a D.C. shunt motor is working at full load and if shunt field circuit suddenly opens this will make armature to take heavy current, possibly burning it.

Last Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

Description : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading

Last Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Description : Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

Last Answer : Which of the following is the least expensive protection for over current in low voltage system?  (A) Rewireable fuse (B) Isolator (C) Oil Circuit breaker (D) Air break circuit breaker

Last Answer : Over voltage protection is recommended for hydro-electric generators, steam turbine generators, gas turbine generators.

Description : Explain how sinusoidal AC voltage is generated by using simple one loop generator.

Last Answer : An electric current produced by means of electrical machine is known as generator which converts mechanical energy into electrical energy. When conductor cuts the magnetic flux, emf induced in it. (Faraday' ... upon position of armature. The nature of emf is alternating as shown by the waveform. 

Description : An SSB transmitter produces a peak-to-peak voltage of 200 V across a 100 Ω antenna load. What is the Peak Envelope Power? A) 49.98 W B) 79.98 W C) 99.96 W D) 199.93 W

Last Answer : An SSB transmitter produces a peak-to-peak voltage of 200 V across a 100 Ω antenna load. What is the Peak Envelope Power? A) 49.98 W B) 79.98 W C) 99.96 W D) 199.93 W

Description : A zener voltage regulator has load requirements of 12 V and 2 A. The zener diode minimum current requirement is 0.2 A. The minimum voltage at input is 24 V. What is the required value of series resistance with source? A) 5.45 Ω B) 6 Ω C) 7.2 Ω D) 6.38 Ω  

Last Answer : A zener voltage regulator has load requirements of 12 V and 2 A. The zener diode minimum current requirement is 0.2 A. The minimum voltage at input is 24 V. What is the required value of series resistance with source? A) 5.45 Ω B) 6 Ω C) 7.2 Ω D) 6.38 Ω  

Description : A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Last Answer : 0

Description : A 3-phase voltage source inverter operates in 180° conduction mode with a star connected resistive load. If input dc voltage is 100 V, then the peak to peak output line voltage is :

Last Answer : A 3-phase voltage source inverter operates in 180° conduction mode with a star connected resistive load. If input dc voltage is 100 V, then the peak to peak output line voltage is : 200 V

Description : Negative voltage regulation is indicative that the load is?

Last Answer : Negative voltage regulation is indicative that the load is capacitive.

Description : In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are?

Last Answer : In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are hysteresis and eddy current losses.

Description : Minimum voltage regulation occurs when the power factor of the load is?

Last Answer : Minimum voltage regulation occurs when the power factor of the load is leading.

Last Answer : A 220 V D.C. generator is run at full speed without any excitation. The open circuit voltage will be about 2 V.

Last Answer : In a separately excited generator supplying rated load the armature reaction is always present.

Description : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave?

Last Answer : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave will be of 5 Hz.

Last Answer : In a D.C. generator in case the resistance of the field winding is increased, then output voltage will decrease.

Description : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as?

Last Answer : The maximum constant load torque under which a synchronous motor will pull into synchronism at rated rotor supply voltage and frequency is known as pull-in torque.

Last Answer : The critical resistance of the D.C. generator is the resistance of field.

Last Answer : Armature reaction in a generator results in demagnetisation of leading pole tip and magnetisation of trailing pole tip.

Description : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be?

Last Answer : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be zero.

Last Answer : An exciter for a turbo generator is a shunt generator.

Last Answer : A D.C. generator can be considered as rotating amplifier.

Last Answer : In a D.C. generator, the critical resistance refers to the resistance of field.

Description : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be?

Last Answer : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be 580 V.

Last Answer : Flashing the field of D.C. generator means creating residual magnetism by a D.C. source.

Last Answer : If a D.C. generator fails to build up the probable cause could not be field resistance less than the critical resistance.

Description : The purpose of providing dummy coils in a generator is?

Last Answer : The purpose of providing dummy coils in a generator is to provide mechanical balance for the rotor.

Description : A shunt generator running at 1000 r.p.m. has generated e.m.f. as 200 V. If the speed increases to 1200 r.p.m., the generated e.m.f. will be nearly?

Last Answer : 200V/E2 = 1000/1200 E2= 240 V

Last Answer : In a D.C. generator the magnetic neutral axis coincides with the geometrical neutral axis, when there is no load on|he generator.

Last Answer : The e.m.f. generated in a D.C. generator is directly proportional to speed of armature.

Last Answer : In a D.C. generator the number of mechanical degrees and electrical degrees will be the same when number of poles is 2.

Last Answer : D.C. generator generally preferred for charging automobile batteries is long shunt compound generator.

Last Answer : The armature core of a D.C. generator is usually made of silicon steel.

Last Answer : In a D.C. generator the ripples in the direct e.m.f. generated are reduced by using carbon brushes of superior quality.

Last Answer : The demagnetising component of armature reaction in a D.C. generator reduces generator e.m.f.

Last Answer : Welding generator will have lap winding.

Last Answer : If brushes of a D.C. generator are moved in order to bring these brushes in magnetic neutral axis, there will be crossmagnetisation as well as demagnetising.

Last Answer : In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be 8.

Last Answer : A separately excited generator as compared to a self-excited generator is amenable to better voltage control, more stable, has exciting current independent of load current.