1 Answer

Answer :

The function of shunt in an ammeter is to by pass the current.

Related questions

Last Answer : An ammeter is a secondary instrument.

Last Answer : Ammeter is a current measuring device having low internal resistance so as to direct all the current flowing in the circuit through it. Hence Ammeter is always connected in series with the circuit. If ... If Ammeter is connected in parallel with the supply, then the supply will be a short circuit.

Last Answer : Yes it can...

Description : Use Voltmeter, ammeter, wattmeter to determine active, reactive and apparent power consumed in given R-L series circuit, draw phasor diagram.

Last Answer : Practical Significance In the industry environment Electrical Engineering diploma graduate are expected to measure basic parameters like voltage, frequency, time period etc. for R-L series circuits. Therefore ... /varying L. 7. Draw the phasor diagram for each of reading for verification.

Description : Write any two disadvantages of ammeter shunts.

Last Answer : Disadvantages of ammeter shunts: 1. Errors are caused because of change in temperature. 2. Most suitable for DC measurement. 3. Power loss takes place.

Description : With neat diagram, explain the working of clip-on ammeter.

Last Answer : Working of Clip on Ammeter: Clip on ammeters are used to measure the high current flowing through bus bar, cable or fuse holders, which act as primary. It consists of split core current ... then clipped over the current carrying conductor. The dial will record the current directly. 

Description : Describe procedure for calibration of ammeter with diagram.

Last Answer : Procedure for Calibration of Ammeter:  In this method, DC potentiometer is used for measurement of voltage across a standard low resistance.  Connect the circuit as shown in the figure, ... S = resistance of potentiometer  And the currents are compared for finding out error in ammeter.

Description : How range of A.C. ammeter & A.C. voltmeter is extended? Draw suitable diagram.

Last Answer : Extension of A.C. Ammeter Range: The range of a.c. ammeter can be extended by using CT, the arrangement is shown in figure. The CT is current transformer having less number of primary turns carrying high ... high magnitude of source voltage. In this way range of a.c. voltmeter can be extended.

Description : State the application of phase sequence indicator; clip on ammeter, frequency meter & P.F. meter.

Last Answer : Phase Sequence Indicator:  1. For finding correct phase sequence of supply  2. For obtaining exact instant of parallel operation of alternators.  3. For obtaining reversal of rotation ...  4. In electroplating industries   5. In various processes industries for measuring power factor

Description : Draw a typical electric circuit including ammeter and voltmeter.

Last Answer : The figure shows typical electric circuit including ammeter and voltmeter. Ammeter is connected in series for measurement of current. Voltmeter is connected in parallel for measurement of voltage. Fuse is use ... are used. If the electric supply is DC the DC ammeter and DC voltmeter are used.

Description : What should be the ideal resistance of ammeter ?

Last Answer : Ideal resistance of ammeter should be zero.

Description : what is ammeter ?

Last Answer : An instrument that is used to measure the amount of current flowing in a circuit.

Description : DC shunt motor

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : If field current is decreased in shunt dc motor, the speed of the motor (a) remains same. (b) increases. (c) decreases. (d) none of the above.

Last Answer : increases

Description : State any four applications of DC shunt motor.

Last Answer : Applications of DC shunt motor: 1) Lathe machines 2) drilling machines 3) milling machines 4) Printing machinery 5) Paper industry 6) centrifugal and reciprocating pumps 7) blowers 8)fans

Description : Why does the speed of a DC shunt motor decrease as the load increases?

Last Answer : Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.

Description : State the use of shunt and series resistance used in extension of meter.

Last Answer : Use of shunt and series resistance: i) Use of shunt: To extend the range of Ammeter. ii) Use of series resistance: To extend the range of Voltmeter.

Description : In which of the following transmission lines, the value of the Shunt admittance should be approximated to zero ? (A) A 66 kV 35 km long line (B) A 132 kV 200 km long line (C) A 220 kV 300 km long line (D) A 400 kV 500 km long line

Last Answer : In which of the following transmission lines, the value of the Shunt admittance should be approximated to zero ? (A) A 66 kV 35 km long line (B) A 132 kV 200 km long line (C) A 220 kV 300 km long line (D) A 400 kV 500 km long line

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Description : Shunt compensation in an EHV line is used to (A) Improve stability. (B) Improve the voltage profile. (C) Reduce the fault level. (D) Substitute for synchronous phase modifier.

Last Answer : Shunt compensation in an EHV line is used to Improve the voltage profile.

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : A shunt fault is characterized by (A) Increase in current, frequency and pf (B) Increase in current, reduction in frequency and pf (C) Increase in current and frequency, reduction in pf (D) Decrease in current and frequency

Last Answer : B

Description : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave?

Last Answer : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave will be of 5 Hz.

Last Answer : A cumulatively compounded long shunt generator when operating as a motor would be differentially compounded long shunt.

Description : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be?

Last Answer : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be 580 V.

Description : A shunt generator running at 1000 r.p.m. has generated e.m.f. as 200 V. If the speed increases to 1200 r.p.m., the generated e.m.f. will be nearly?

Last Answer : 200V/E2 = 1000/1200 E2= 240 V

Last Answer : If a D.C. shunt motor is working at full load and if shunt field circuit suddenly opens this will make armature to take heavy current, possibly burning it.

Last Answer : The purpose of retardation test on D.C. shunt machines is to find out stray losses.

Last Answer : In a manual shunt motor starter over load relay is connected in series and no volt relay in parallel with the load.

Last Answer : D.C. shunt motors are used for driving machine tools.

Last Answer : If the speed of a D.C. shunt motor is increased, the back e.m.f. of the motor will increase.

Last Answer : For a D.C. shunt motor if the excitation is changed torque will change but power will remain constant.

Last Answer : The speed of a D.C. shunt motor can be increased by increasing the resistance in field circuit.

Last Answer : The armature torque of the D.C. shunt motor is proportional to armature current.

Last Answer : As the load is increased the speed of D.C. shunt motor will reduce slightly.

Last Answer : The mechanical power developed by a shunt motor will be maximum when the ratio of back e.m.f. to applied voltage is 0.5.

Last Answer : In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.

Last Answer : In case of D.C. shunt motors the speed is dependent on back e.m.f. only because flux is practically constant in D:C. shunt motors.

Last Answer : In a D.C. shunt motor, speed is independent of armature current.

Last Answer : The speed of a D.C. shunt motor more than its full-load speed can be obtained by decreasing the field current.

Last Answer : In D.C. shunt motors as load is reduced the speed will remain almost constant.

Last Answer : If the field of a D.C. shunt motor gets opened while motor is running the motor will attain dangerously high speed.

Last Answer : Shunt capacitance is neglected while considering short transmission line.

Description : D.C. shunt relays are made of?

Last Answer : D.C. shunt relays are made of many turns of thin wire.

Description : Why shunt capacitor is used?

Last Answer : To improve voltage at receiving end and power factor

Description : Is the search function not working?

Last Answer : Search hasn’t been working for a while. I know that the tech mods are looking at it, but my impression is that it’s more complicated than any of the other fixes they’ve done.

Description : State at least one function and the material used for the following parts of DC Motor.

Last Answer : Part Function Material Yoke -Provides mechanical support for poles -Acts as protecting cover for machine -Provides path for magnetic flux Cast Iron OR Cast Steel Field Winding - ... Pole core  Provides mechanical support to field winding. Cast Iron OR Cast Steel

Description : Draw the block diagram of regulated power supply, explain function of each block and draw waveforms of each stage.

Last Answer : 1. A step down transformer 2. A rectifier 3. A filter 4. A regulator Operation of Regulated Power Supply:- Step Down Transformer:- A step down transformer will ... regulator. A regulator will maintain the output constant even when changes at the input or any other changes occur.

Description : Draw block diagram of PLL as a FM demodulator. Explain function of each block.

Last Answer : Operation:  The FM signal which is to be demodulated is applied at the input of the PLL.  the PLL is locked to the FM  The error voltage produced at ... using PLL ensures a high Linearity, between the instantaneous input frequency and VCO control voltage (error amplifier output)

Description : Give the function of fuse and switch.

Last Answer : Functions of fuse:  * To break the circuit under fault condition.  * To provide overcurrent protection to the circuit.  * To provide short circuit protection to the circuit.  * To provide ...  * To make the electric circuit manually.  * To break the electric circuit manually.