1 Answer

Answer :

In a dynamometer 3-phase power factor meter, the planes of the two moving coils are at 120°.

Related questions

Description : With a neat sketch explain working of 1 phase dynamometer type power factor meter.

Last Answer : Working of 1 phase dynamometer type power factor meter : The current coil is connected in series with load. Two pressure coils marked as A and B are connected across the supply terminals ... becomes stationary and the pointer shows steady deflection corresponding to the power factor of the load. 

Last Answer : In a single phase power factor meter the phase difference between the currents in the two pressure coils is exactly 90°.

Last Answer : The two pressure coils of a single phase power factor meter have the same dimensions and the same number of turns.

Last Answer : A power factor meter has one current circuit and two pressure circuits.

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Last Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Last Answer : The resistance in the circuit of the moving coil of a dynamometer wattmeter should be high.

Description : working of distortion factor meter with block diagram

Last Answer : Working : Initially the switch S is kept at position 1.The attenuator gets excluded and the bridge T network is adjusted for full suppression of fundamental frequency and hence we get ... is obtained on the meter.Thus the total rms distortion is indicated by the reading of attenuator. 

Last Answer : A dynamometer wattmeter can be used for both D.C. and A.C.

Last Answer : The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

Description : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

Last Answer : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is 11%

Description : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be?

Last Answer : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be 0.5.

Description : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was?

Last Answer : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was unity.

Last Answer : In a low power factor wattmeter the compensating coil is connected in series with pressure coil.

Last Answer : In a low power factor wattmeter the pressure coil is connected to the load side of the current coil.

Last Answer : In a Weston frequency meter, the magnetic axes of the two fixed coils are perpendicular.

Description : Explain the “mitigation of power theft” and “faulty meter replacement” for energy conservation techniques to reduce commercial losses. 

Last Answer : Energy conservation techniques to reduce commercial losses:  1. Mitigation of Power Theft: Power theft being the most important issue which all of the service providing utilities ... agricultural sector. Prepaid meters may prove effective measures against unauthorized abstraction of energy. 

Description : State the effects of errors in dynamometer type wattmeter due to i) pc- inductance ii) pc- capacitance iii) mutual inductance iv) Connection.

Last Answer : Errors in wattmeter:  i) pc - inductance: Pressure coil inductance causes wattmeter to read more power than actual .  ii) pc-capacitance: The wattmeter reads less power.  iii) ... iv) Connection: In uncompensated wattmeter , the reading of wattmeter includes the powerloss in coils. 

Description : State any four errors that occur in dynamometer type wattmeter

Last Answer : Errors that occur in dynamometer type wattmeter: 1. Errors due to method of connection. 2. Error due to pressure coil inductance. 3. Error due to pressure coil Capacitance. 4. Error due to mutual ... Error due to eddy currents. 7. Temperature error. 8. Error due to vibration of moving system

Description : With neat diagram explain constructional details of dynamometer type wattmeter.

Last Answer : Working Principle of Wattmeter: It consists of two stationary coils, called current coils and one moving coil, called voltage or potential coil. The moving coil is mounted on the spindle, in the gap ... experiences a force and tends to move in the direction as per Fleming's left hand rule. 

Last Answer : The power factor of a single-phase induction motor is usually lagging.

Description : In an alternator at lagging power factor the generated voltage per phase as compared to that at unity power factor?

Last Answer : In an alternator, at lagging power factor the generated voltage per phase as compared to that at unity power factor must be more than terminal voltage.

Description : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is

Last Answer : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is 200µNm

Description : What is meant by Power factor?

Last Answer : Ans. Power factor means ratio of true power to apparent power. It is cosine of phase angle between voltage and current. Its value is 1 for Unity P.F. Loads, 0 to 1 lagging for inductive loads and o to 1 leading for capacitive loads.

Description : State the effects of low power factor on efficiency and voltage regulation of short transmission lines. 

Last Answer : i) Effect of Low power factor on efficiency:- When power factor of load reduces current drawn by transmission line increases so copper losses in transmission line increases, hence transmission ... increases, so voltage drop in transmission line increases so regulation increases. (Become Poor) 

Description : Briefly explain how the power factor of an inductive circuit can be improved.

Last Answer : As we know that power factor should be corrected to ensure that the current supplied is cost friendly. Meaning the power factor should be around one but not greater than one(0.8-0.9) in a ... an inductive circuit due to the inductive reactance which oppose the change of current in the ac circuit. 

Description : Why capacitors are used to improve power factor?

Last Answer :  Capacitors generate reactive power instead of that drawn from source which is required by inductive loads.so it reduce the reactive current which is drawn from source to be drawn from capacitor.This control in Electric bills cost.

Description : Discuss how power factor tariff results into energy conservation.

Last Answer : Power factor tariff results into energy conservation: i) Applying incentives and penalties according to power factor is an effective way, which enables consumer to improve power factor so that he can ... finally leads to reduction in the current drawn by the load and helps for energy conservation.

Description : Draw and explain bulk correction method for power factor & control.

Last Answer : Bulk correction method for power factor & control: i) Here individual starter controls the capacitors located at distribution panel. ii) Centralized compensation is employed in large industrial plants where many ... capacitor units in steps to maintain P.F. more than preset limit (0.95). 

Description : State the incentives and penalties related with power factor tariff.

Last Answer : Incentives and penalties related with power factor tariff: In addition to basic tariff (Maximum Demand Tariff / KVA Maximum Demand Tariff / Load factor tariff) the tariff in which P.F. of ... industrial consumer/H.T/ commercial consumers with contract demand above 80 kw/ 100Kva/107 hp consumer.

Description : State the significance of power factor.

Last Answer : Significance of power factor:-  1. Cosine of angle between voltage & current in a circuit is called power factor. 2. It is a measure of the real power in a circuit. 3. Inductive & ... KVA rating equipment 5. Greater conductor size 6. CosØ = R/Z  CosØ= Active Power/ Apparent Power 

Description : A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Last Answer : 0

Description : The power factor of dielectric :  (A) is a function of temperature of the dielectric only (B) depends only on voltage stress to which the dielectric is stressed (C) always constant (D) both (A) and (B)

Last Answer : The power factor of dielectric :  (A) is a function of temperature of the dielectric only (B) depends only on voltage stress to which the dielectric is stressed (C) always constant (D) both (A) and (B)

Description : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is  (1) 122.8 GWh (2) 198.55 GWh (3) 128.2 GWh (4) 188.82 GWh

Last Answer : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is 122.8 GWh

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Description : The benefit of power factor correction in a power system is (A) lower power consumption (B) increased demand charge (C) reduced load carrying capabilities in existing lines (D) reduced voltage profile

Last Answer : The benefit of power factor correction in a power system is lower power consumption

Description : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are (A) 0.5 pu ... pu, 0.5 pu (C) 0.707 pu, 0.707 pu (D) 0.5 pu, 0.5 pu

Last Answer : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are 0.866 pu, 0.5 pu

Description : The power factor of a D.C. circuit is always?

Last Answer : The power factor of a D.C. circuit is always unity.

Description : The ratio of active power to apparent power is known as____ factor.

Last Answer : The ratio of active power to apparent power is known as power factor.

Description : The input of an A.C. circuit having power factor of 0.8 lagging is 40 kVA The power drawn by the circuit is?

Last Answer : The input of an A.C. circuit having power factor of 0.8 lagging is 40 kVA The power drawn by the circuit is 32 kW.

Description : Power factor of electric bulb is?

Last Answer : Power factor of electric bulb is unity.

Description : The power factor at resonance in R-L- C parallel circuit is?

Last Answer : since a rlc circuit at resonance behaves like a pure resistive circuit, i.e there is no phase difference between current and voltage, hence the power factor is unity.

Description : Power factor of the system is kept high?

Last Answer : Power factor of the system is kept high to reduce line losses, to maximise the utilization of the capacities of generators, lines and transformers, to reduce voltage regulation of the line.

Description : Power factor of an inductive circuit is usually improved by connecting capacitor to it in?

Last Answer : Power factor of an inductive circuit is usually improved by connecting capacitor to it in parallel.

Description : Capacitors for power factor correction are rated in?

Last Answer : Capacitors for power factor correction are rated in kVAR.

Description : Poor power factor?

Last Answer : Poor power factor reduces load handling capability of electrical system, results in more power losses in the electrical system, overloads alternators, transformers and distribution lines, results in more voltage drop in the line.

Description : Power factor of an electrical circuit is equal to?

Last Answer : Power factor of an electrical circuit is equal to R/Z, cosine of phase angle difference between current and voltage, kW/kVA.

Last Answer : When a D.C. series motor is connected to A.C. supply, the power factor will be low because of high inductance of field and armature circuits.

Description : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Last Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

Last Answer : The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.

Last Answer : For power factor correction, synchronous motors operate at no-load and greatly over-excited fields.