Description : Explain the three phase 120 degree mode VSI.
Last Answer : Three phase 120 degree mode VSI: In the 120-degree mode voltage source inverter, each thyristor conducts for 120 degree of a cycle. 120-degree mode VSI required six steps, each step of 60 degree ... conduct from the upper group and one thyristor will conduct from lower group.