Power factor of an inductive circuit is usually improved by connecting capacitor to it in?

1 Answer

Answer :

Power factor of an inductive circuit is usually improved by connecting capacitor to it in parallel.

Related questions

Description : Briefly explain how the power factor of an inductive circuit can be improved.

Last Answer : As we know that power factor should be corrected to ensure that the current supplied is cost friendly. Meaning the power factor should be around one but not greater than one(0.8-0.9) in a ... an inductive circuit due to the inductive reactance which oppose the change of current in the ac circuit. 

Description : Pure inductive circuit takes power from the A.C. line when?

Last Answer : It takes power when voltage decreases and current increases.

Last Answer : The power factor of a single-phase induction motor is usually lagging.

Description : How does a capacitor improve power factor?

Last Answer : Every circuit are usually more inductive than capacitive.it means that the current lags by voltage at small angle.hence we have to compensate this situation so we use Capacitor then this lag is compensate ... angle becomes low and the value of cos(phase angle) is increase and hence power also max.

Description : steady-state stability of a power system is improved by

Last Answer : steady-state stability of a power system is improved by using double circuit line instead of single circuit line

Description : In a pure inductive circuit if the supply frequency is reduced to 1/2, the current will?

Last Answer : In a pure inductive circuit if the supply frequency is reduced to 1/2, the current will be doubled.

Description : In a purely inductive circuit?

Last Answer : In a purely inductive circuit actual power is zero.

Description : In a pure inductive circuit?

Last Answer : Voltage lagging in inductor

Description : Time constant of an inductive circuit?

Last Answer : Time constant of an inductive circuit increases with increase of inductance and decrease of resistance.

Description : Pure inductive circuit?

Last Answer : Pure inductive circuit takes power from the line during some part of the cycle and then returns back to it during other part of the cycle.

Description : The power factor of a D.C. circuit is always?

Last Answer : The power factor of a D.C. circuit is always unity.

Description : The input of an A.C. circuit having power factor of 0.8 lagging is 40 kVA The power drawn by the circuit is?

Last Answer : The input of an A.C. circuit having power factor of 0.8 lagging is 40 kVA The power drawn by the circuit is 32 kW.

Description : The power factor at resonance in R-L- C parallel circuit is?

Last Answer : since a rlc circuit at resonance behaves like a pure resistive circuit, i.e there is no phase difference between current and voltage, hence the power factor is unity.

Description : Power factor of an electrical circuit is equal to?

Last Answer : Power factor of an electrical circuit is equal to R/Z, cosine of phase angle difference between current and voltage, kW/kVA.

Description : What is the power factor of purely resistive circuit.

Last Answer : Unity that is 1

Last Answer : The inductive interference between power and communication line can be minimized by transposition of the power line, transposition of the communication line.

Description : For a DC circuit capacitor is

Last Answer : For a DC circuit capacitor is virtually an open circuit

Description : What is the purpose of a capacitor in an AC circuit?

Last Answer : Every AC supply is not ideal AC it contains DC component so to provide restriction to DC component in supply we have to use Capacitor

Last Answer : The value of starting capacitor of a fractional horse power motor will be 300 uF .

Description : The rate of rise of current through an inductive coil is maximum?

Last Answer : The rate of rise of current through an inductive coil is maximum at the start of the current flow.

Description : Why capacitors are used to improve power factor?

Last Answer :  Capacitors generate reactive power instead of that drawn from source which is required by inductive loads.so it reduce the reactive current which is drawn from source to be drawn from capacitor.This control in Electric bills cost.

Description : With a neat sketch explain working of 1 phase dynamometer type power factor meter.

Last Answer : Working of 1 phase dynamometer type power factor meter : The current coil is connected in series with load. Two pressure coils marked as A and B are connected across the supply terminals ... becomes stationary and the pointer shows steady deflection corresponding to the power factor of the load. 

Description : State the significance of power factor.

Last Answer : Significance of power factor:-  1. Cosine of angle between voltage & current in a circuit is called power factor. 2. It is a measure of the real power in a circuit. 3. Inductive & ... KVA rating equipment 5. Greater conductor size 6. CosØ = R/Z  CosØ= Active Power/ Apparent Power 

Description : The power factor of dielectric :  (A) is a function of temperature of the dielectric only (B) depends only on voltage stress to which the dielectric is stressed (C) always constant (D) both (A) and (B)

Last Answer : The power factor of dielectric :  (A) is a function of temperature of the dielectric only (B) depends only on voltage stress to which the dielectric is stressed (C) always constant (D) both (A) and (B)

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Last Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Description : The ratio of active power to apparent power is known as____ factor.

Last Answer : The ratio of active power to apparent power is known as power factor.

Description : Power factor of electric bulb is?

Last Answer : Power factor of electric bulb is unity.

Description : Power factor of the system is kept high?

Last Answer : Power factor of the system is kept high to reduce line losses, to maximise the utilization of the capacities of generators, lines and transformers, to reduce voltage regulation of the line.

Description : Capacitors for power factor correction are rated in?

Last Answer : Capacitors for power factor correction are rated in kVAR.

Description : Poor power factor?

Last Answer : Poor power factor reduces load handling capability of electrical system, results in more power losses in the electrical system, overloads alternators, transformers and distribution lines, results in more voltage drop in the line.

Description : What is meant by Power factor?

Last Answer : Ans. Power factor means ratio of true power to apparent power. It is cosine of phase angle between voltage and current. Its value is 1 for Unity P.F. Loads, 0 to 1 lagging for inductive loads and o to 1 leading for capacitive loads.

Description : State the effects of low power factor on efficiency and voltage regulation of short transmission lines. 

Last Answer : i) Effect of Low power factor on efficiency:- When power factor of load reduces current drawn by transmission line increases so copper losses in transmission line increases, hence transmission ... increases, so voltage drop in transmission line increases so regulation increases. (Become Poor) 

Description : Discuss how power factor tariff results into energy conservation.

Last Answer : Power factor tariff results into energy conservation: i) Applying incentives and penalties according to power factor is an effective way, which enables consumer to improve power factor so that he can ... finally leads to reduction in the current drawn by the load and helps for energy conservation.

Description : Draw and explain bulk correction method for power factor & control.

Last Answer : Bulk correction method for power factor & control: i) Here individual starter controls the capacitors located at distribution panel. ii) Centralized compensation is employed in large industrial plants where many ... capacitor units in steps to maintain P.F. more than preset limit (0.95). 

Description : State the incentives and penalties related with power factor tariff.

Last Answer : Incentives and penalties related with power factor tariff: In addition to basic tariff (Maximum Demand Tariff / KVA Maximum Demand Tariff / Load factor tariff) the tariff in which P.F. of ... industrial consumer/H.T/ commercial consumers with contract demand above 80 kw/ 100Kva/107 hp consumer.

Description : A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Last Answer : 0

Description : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is  (1) 122.8 GWh (2) 198.55 GWh (3) 128.2 GWh (4) 188.82 GWh

Last Answer : Power station having Load factor = 70%, capacity factor = 50%, used factor = 60%, maximum demand = 20MW then annual energy production is 122.8 GWh

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Description : The benefit of power factor correction in a power system is (A) lower power consumption (B) increased demand charge (C) reduced load carrying capabilities in existing lines (D) reduced voltage profile

Last Answer : The benefit of power factor correction in a power system is lower power consumption

Description : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are (A) 0.5 pu ... pu, 0.5 pu (C) 0.707 pu, 0.707 pu (D) 0.5 pu, 0.5 pu

Last Answer : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are 0.866 pu, 0.5 pu

Last Answer : The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

Last Answer : In a dynamometer 3-phase power factor meter, the planes of the two moving coils are at 120°.

Last Answer : In a single phase power factor meter the phase difference between the currents in the two pressure coils is exactly 90°.

Last Answer : The two pressure coils of a single phase power factor meter have the same dimensions and the same number of turns.

Last Answer : A power factor meter has one current circuit and two pressure circuits.

Last Answer : In a low power factor wattmeter the compensating coil is connected in series with pressure coil.

Last Answer : In a low power factor wattmeter the pressure coil is connected to the load side of the current coil.

Last Answer : When a D.C. series motor is connected to A.C. supply, the power factor will be low because of high inductance of field and armature circuits.

Description : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?

Last Answer : A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because stator supply is not required to produce magnetic field.

Last Answer : The standard full-load power factor ratings for synchronous motors are unity or 0.8 leading.