The initial rate of rise of current through a coil of inductance 10 H when suddenly connected to a D.C. supply of 200 V is_______Vs.

1 Answer

Answer :

The initial rate of rise of current through a coil of inductance 10 H when suddenly connected to a D.C. supply of 200 V is 20 Vs

Related questions

Description : The rate of rise of current through an inductive coil is maximum?

Last Answer : The rate of rise of current through an inductive coil is maximum at the start of the current flow.

Description : lt the length, number of turns and area of a coil are  doubled, the inductance of the coil

Last Answer : lt the length, number of turns and area of a coil are  doubled, the inductance of the coil is quadrupled

Description : The inductance of a coil can be increased by?

Last Answer : The inductance of a coil can be increased by choosing core material having high relative permeability.

Description : Inductance of coil?

Last Answer : Inductance of coil increases with the increase in supply frequency.

Description : Inductance of a coil Varies?

Last Answer : Inductance of a coil Varies as directly as the cross-sectional area of magnetic core and inversely as the length of the iron path.

Description : The self inductance of a coil can be measured using (A) Wien’s Bridge (B) Schering Bridge (C) Anderson’s Bridge (D) Wheatstone Bridge

Last Answer : The self inductance of a coil can be measured using Anderson’s Bridge

Description : Inductance affects the direct current flow?

Last Answer : Inductance affects the direct current flow at the time of turning on and off.

Description : Explain the concept of initial and final conditions in switching for L and C.

Last Answer : i) Inductor: The current through an inductor cannot change instantly. If the inductor current is zero just before switching, then whatever may be the applied voltage, just after switching the inductor ... open-circuit.  The initial and final conditions are summarized in following table:

Description : When both the inductance and resistance of a coil are doubled the value of?

Last Answer : When both the inductance and resistance of a coil are doubled the value of time constant remains unchanged.

Description : With rise in temperature the resistance of semi-conductors?

Last Answer : With rise in temperature the resistance of semi-conductors decreases.

Description : effect of inductance and capacitance on performance of transmission line.

Last Answer : Following are the effect on performance of transmission line:  1. Due to inductance (L) voltage drop in transmission line produces.  2. Capacitor (C) draws charging current ... , transmission line efficiency, voltage regulation & also power factor of transmission line gets affected. 

Description : What is inductance?

Last Answer : Inductance is the property of Material by which it opposes the any change of magnitude or direction of electric current passing through the conductor. The inductance is denoted by L. The unit of inductance is Henry (H).

Description : Self inductance formula

Last Answer : Self inductance formula

Description : Self induced voltage across an inductance

Last Answer : Self induced voltage across an inductance

Description : Describe with working of LCR meter for measurement of inductance. 

Last Answer : working of LCR:- A LCR meter (Inductance (L), Capacitance (C), and Resistance (R) test equipment used to measure the inductance, capacitance and, resistance of a component. It works on the ... in parallel (as would be encountered in measuring a capacitor with a leaky dielectric) [Q setting ] 

Description : What is the reciprocal of inductance?

Last Answer : This term is not exist

Last Answer : Unit of inductance is Henry denoted by capital H .

Description : State the impact of inductance and resistance on transmission line performance

Last Answer : Impact of inductance on transmission line: 1) It causes IXL drop in transmission line which affects regulation. 2) It is the only parameter which decides power transmission capacity of line i. ... is very small, it causes losses, temperature rise& poor voltage regulation so it cannot be neglected

Description : Inductance

Last Answer : Inductance

Description : For 11kV line the inductance per km per phase will be of the order of:  (A) 1 H (B) 0.1 H (C) 1 mH (D) 0.1 mH

Last Answer : For 11kV line the inductance per km per phase will be of the order of: 1 mH

Description : The bridge method commonly used for finding mutual inductance is (A) Heaviside Campbell bridge (B) Schering bridge (C) De Sauty bridge (D) Wien bridge

Last Answer : The bridge method commonly used for finding mutual inductance is Heaviside Campbell bridge

Last Answer : If an inductance is connected in one arm of bridge and resistances in the remaining three arms the bridge cannot be balanced.

Last Answer : For measurement of inductance having high value, we should use Hay's bridge.

Last Answer : For measurement of mutual inductance we can use Heaviside bridge.

Last Answer : In an Anderson bridge, the unknown inductance is measured in terms of known capacitance and resistance.

Description : Name the material used for :- (i) Moving coil (ii) Permanent magnet in PMMC instrument.

Last Answer : (i) Material used for Moving coil: Copper, Aluminum( some times)  (ii) Permanent magnets are made of special alloys such as :  Aluminum-Nickel-Cobalt (Alnicos)  Strontium-Iron  Neodymium-Iron-Boron  Samarium-Cobalt.

Description : State the material used for moving coil and former for PMMC instruments. 

Last Answer : Material Used for Moving Coil and Former for PMMC Instruments:  Material used for moving coil: Copper  Material used for Former: Aluminium

Description : A Peterson coil is ________ A) An arc generating coil B) An arc suppressing coil C) An arc inducing coil D) None of these

Last Answer : A Peterson coil is An arc suppressing coil

Description : What is the difference between a coil and an inductor?

Last Answer : Inductor is covering with insulating material is called coil.so they differentiate between coil and inductor.

Description : The unit heat rate characteristic of a thermal power unit shows :  (A) Heat input per kWh of output versus the megawatt output of unit  (B) Heat input per kW of output versus the megawatt output ... hour output of unit  (D) Heat input per kW of output versus the megawatt hour output of unit

Last Answer : The unit heat rate characteristic of a thermal power unit shows : Heat input per kWh of output versus the megawatt output of unit 

Description : What do you mean by coil?

Last Answer : Ans. Having one or more turns connected in series is called coil.

Description : State the function of overload coil and No volt coil in dc motor starter.

Last Answer : Function of Overload Coil: When DC motor is overloaded, the overload coil carries the overload current and produces strong magnetic field to attract a plunger, which short the terminals of ... dc motor is prevented from restarting automatically on recovery of supply without starter and protected.

Description : The purpose of the restraining coil in a biased differential relay is  (A) To reduce CT saturation during fault.  (B) To increase the sensitivity of the relay.  (C) To match the transformation ratio.  (D) To limit the spill current through the relay during heavy external fault.

Last Answer : d

Description : Permanent magnet moving coil instruments are used for

Last Answer : PMME are mostly used for measuring voltage and current.

Description : Peterson coil is used for :  (A) shunt compensation of lines (B) grounding of system neutral (B) reduce fault currents (D) connecting interconnected systems

Last Answer : Peterson coil is used for : grounding of system neutral

Description : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is

Last Answer : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is 200µNm

Description : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is (A) 1 Ω (B) 1.001 Ω (C) 0.5 Ω (D) 10 Ω

Last Answer : A PMMC instrument has FSD of 100 μA and a coil resistance of 1 kΩ. To convert the instrument into an ammeter with full scale deflection of 100 mA, the required shunt resistance is 1.001 Ω

Description : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is (A) 9997 Ω (B) 10000 Ω (C) 997 Ω (D) 10003 Ω

Last Answer : A moving coil meter has a resistance of 3 Ω and gives full scale deflection with 30 mA. To measure voltage up to 300 V, the external resistance to be connected in series with the instrument is 9997 Ω

Description : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

Last Answer : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is 11%

Last Answer : In a low power factor wattmeter the compensating coil is connected in series with pressure coil.

Last Answer : In a low power factor wattmeter the pressure coil is connected to the load side of the current coil.

Last Answer : The multiplier and the meter coil in a voltmeter are in series.

Last Answer : A moving-coil permanent-magnet instrument can be used as flux-meter by eliminating the control springs.

Last Answer : A moving-coil permanent-magnet instrument can be used as ammeter by using a low resistance shunt.

Last Answer : Armature coil is short circuited by brushes when it lies along neutral axis.

Last Answer : Open circuited armature coil of a D.C. machine is identified by the scarring of the commutator segment to which open circuited coil is connected and indicated by a spark completely around the commutator.

Last Answer : In a shaded pole motor, the shading coil usually consist of a single turn of heavy copper wire which is short-circuited and carries only induced current.

Description : How to Slow Your Heart Rate ?

Last Answer : How to Slow Your Heart Rate Tachycardia or palpitation is a condition where your heart rate is higher than the normal value of 60-100 beats per minute (bpm) . This is usually a symptom ... An early detection of any illness is very important to prevent it from getting worse and avoid complications.

Description : How to Calculate Your Heart Rate ?

Last Answer : How to Calculate Your Heart Rate The heart rate reflects your current state of health, more specifically, it shows your fitness level and at some point, your metabolic rate. It is only a rough estimate ... often feel light, active, and happy each time, since they are clear signs of good health.

Description : What are the different heart rate monitors and how to make a choice?

Last Answer : What are the different heart rate monitors and how to make a choice? The time when only professional athletes could afford training with a heart rate monitor is already in the past. Today literally anyone ... is that the device can withstand dives to a depth of more than 10 meters. Happy choice!