The normal value of the armature resistance of a d.c. motor is?

1 Answer

Answer :

The normal value of the armature resistance of a d.c. motor is 0.5.

Related questions

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Last Answer : When the armature of a D.C. motor rotates, e.m.f. induced is back e.m.f.

Description : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is

Last Answer : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is 0.87

Last Answer : The armature voltage control of D.C. motor provides constant torque drive.

Last Answer : The armature torque of the D.C. shunt motor is proportional to armature current.

Last Answer : In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.

Description : Armature control of DC motor

Last Answer : Armature control of DC motor

Last Answer : The starting resistance of a D.C. motor is generally low.

Last Answer : The resistance of armature winding depends on length of conductor, cross-sectional area of the conductor, number of conductors.

Last Answer : In a A.C. series motor armature coils are usually connected to commutator through resistance.

Last Answer : In a synchronous motor, the armature current has large values for high and low excitation.

Last Answer : The armature current of the synchronous motor has large values for low and high excitation.

Description : In dc machines, the armature windings are placed on the rotor because of the necessity for  (1) electromechanical energy conversion (2) generation of voltage (3) commutation (4) development of torque

Last Answer : 3  Commutation

Description : The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is  (1) 1000V (2) 100V (3) 600V (4) 10,000V

Last Answer : The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is 1000V

Description : Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : Open circuited armature coil of a D.C. machine is identified by the scarring of the commutator segment to which open circuited coil is connected and indicated by a spark completely around the commutator.

Last Answer : The armature core of a D.C. generator is usually made of silicon steel.

Last Answer : The demagnetising component of armature reaction in a D.C. generator reduces generator e.m.f.

Description : Why is the armature of DC generator laminated?

Last Answer : The armature of DC generator is laminated to reduce eddy current losses.

Description : D.C. motor is to drive a load which has certain minimum value for most of the time and some peak value for short duration. We will select the?

Last Answer : DC motor mostly preferred is DC series motor becaus the load is continuous for a long time

Description : The induced e.m.f. in the armature conductors of a d.c. motor is?

Last Answer : The induced e.m.f. in the armature conductors of a d.c. motor is sinusoidal.

Description : Explain the necessity of starter for D.C. motor. State various types of D.C. motor starter. 

Last Answer : Necessity of Starter for D.C. Motor: Armature current is given by equation Ia = (V−Eb)/Ra i) If the motor is at standstill or rest, back emf Eb is zero (as Eb= ZNP/(60A), at start speed N ... . Types of D.C. motor starters: i) Two point starter ii)Three point starter iii) Four point starter

Description : State at least one function and the material used for the following parts of DC Motor.

Last Answer : Part Function Material Yoke -Provides mechanical support for poles -Acts as protecting cover for machine -Provides path for magnetic flux Cast Iron OR Cast Steel Field Winding - ... Pole core  Provides mechanical support to field winding. Cast Iron OR Cast Steel

Description : Why does the speed of a DC shunt motor decrease as the load increases?

Last Answer : Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.

Description : A d.c. motor can be looked upon as d.c. generator with the power flow?

Last Answer : A d.c. motor can be looked upon as d.c. generator with the power flow reversed.

Description : The Eb/V ratio of a d.c. motor is an indication of its?

Last Answer : The Eb/V ratio of a d.c. motor is an indication of its efficiency.

Description : The counter e.m.f. of a d.c. motor?

Last Answer : The counter e.m.f. of a d.c. motor helps in energy conversion.

Description : In a d.c. motor, unidirectional torque is produced with the help of

Last Answer : Commutator provides unidirectional torque and pulsating dc

Description : In DC motor iron losses are occurred in?

Last Answer : In DC motor iron losses are occurred in the armature.

Last Answer : Series motor has got maximum self relieving property.

Description : D.C. motor is to a drive a load which is almost nil for certain part of the load cycle and peak value for short duration. We will select the?

Last Answer : D.C. motor is to a drive a load which is almost nil for certain part of the load cycle and peak value for short duration. We will select the compound motor.

Last Answer : If a D.C. shunt motor is working at full load and if shunt field circuit suddenly opens this will make armature to take heavy current, possibly burning it.

Last Answer : Shunt motors,  Series motors, Compound motors

Last Answer : Torque developed by a D.C. motor depends upon magnetic field, active length of the conductor, current flow through the conductors, number of conductors, radius of armature.

Last Answer : If the speed of a D.C. shunt motor is increased, the back e.m.f. of the motor will increase.

Last Answer : The current drawn by the armature of D.C. motor is directly proportional to the torque required.

Last Answer : In a D.C. series motor, if the armature current is reduced by 50%, the torque of the motor will be equal to 25% of the previous value.

Description : Ratio of the rotor reactance X to the rotor resistance R for a two-phase servo motor (A) is equal to that of a normal induction motor (B) is less than that of a normal induction motor (C) ... than that of a normal induction motor (D) may be less or greater than that of a normal induction motor

Last Answer : C

Last Answer : In a capacitor start single-phase motor, when capacitor is replaced by a resistance motor will continue to run in same direction.

Description : We connected a 35V dc supply to a resistance of 600 Ohm in series with an unknown resistance R.A. voltmeter having a resistance of 1.2 kOhm is connected across 600 Ohm resistance and read 5v. The value of resistance R will be

Last Answer : We connected a 35V dc supply to a resistance of 600 Ohm in series with an unknown resistance R.A. voltmeter having a resistance of 1.2 kOhm is connected across 600 Ohm resistance and read 5v. The value of resistance R will be 2.4 kOhm

Last Answer : The critical resistance of the D.C. generator is the resistance of field.

Last Answer : In a D.C. generator, the critical resistance refers to the resistance of field.

Description : The mechanical power developed by the armature of a d.c. motor is equal to?

Last Answer : The mechanical power developed by the armature of a d.c. motor is equal to armature current multiplied by back e.m.f.

Description : DC MOTOR MCQ

Last Answer : 101. Which of the following loss in a D.C. generator is dissipated in the form of heat? (a) Mechanical loss (b) Core loss (c) Copper loss (d) All of the above Ans: d 102. Which of the following ... (b) does not run as a generator (c) also runs as a motor comes to stop after sometime Ans: a

Description : State the modification to be done in dc series motor to work satisfactorily as ac series motor. State applications of ac series motor.

Last Answer : Modifications are necessary in a dc series motor so that it operates satisfactorily on ac supply. The modifications are as follows:  1) AC series motor is built with a few field turns as ... and grinders 5) High speed vacuum cleaners 6) Sewing machines 7) Food processors 8) Drilling machine 

Description : DC motor gross torque example

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : DC shunt motor

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : DC motor brake test numerical

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : Brake test on DC series motor

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : If field current is decreased in shunt dc motor, the speed of the motor (a) remains same. (b) increases. (c) decreases. (d) none of the above.

Last Answer : increases