1 Answer

Answer :

The thermocouple instruments do not have High degree of measuring accuracy.

Related questions

Last Answer : Thermocouple instruments are also known as Rectifier instruments.

Description : Thermocouple instruments can be used for a frequency range upto   (a) 100Hz (b) 5000 Hz (c) 1 MHz (d) 50 MHz and above 

Last Answer : Thermocouple instruments can be used for a frequency range upto 50 MHz and above 

Description : Which of the following instruments can be used for measurement of very high value resistances such as insulation resistance in industries? A) Wheatstone bridge B) Megger C) Ohm-meter D) Resistive potentiometer 

Last Answer : Which of the following instruments can be used for measurement of very high value resistances such as insulation resistance in industries? A) Wheatstone bridge B) Megger C) Ohm-meter D) Resistive potentiometer 

Description :  Highest flux density exists inside which of the following instruments? A) Electrodynamic instruments B) Hot wire instruments C) Moving iron instruments D) Moving coil instruments

Last Answer : Highest flux density exists inside which of the following instruments? A) Electrodynamic instruments B) Hot wire instruments C) Moving iron instruments D) Moving coil instruments 

Description : The type of instruments used mainly for standardizing instruments in laboratories is (a) Indicating instrument (b) Integrating instrument (c) Absolute instrument (d) Recording instrument  

Last Answer : Ans:Option C

Description : Eddy current damping is normally used in the instruments of (a) Induction type (b) Moving iron type (c) Permanent magnet moving coil type (d) Nothing can be said 

Last Answer : Permanent  magnetic  moving  coil  instrument.

Description : Electrostatic type instruments are primarily used as 

Last Answer : Voltmeter

Description : The force required to move the pointer in an indicating instruments is

Last Answer : The force required to move the pointer in an indicating instruments is deflecting force

Description : Horizontally mounted moving iron instruments use   (a) Eddy current damping (b) Electromagnetic damping (c) Fluid friction damping (d) Air friction damping

Last Answer : Horizontally mounted moving iron instruments use Air friction damping

Description : Permanent magnet moving coil instruments are used for

Last Answer : PMME are mostly used for measuring voltage and current.

Last Answer : PMMC type instruments normally use Eddy current damping.

Last Answer :  Electrostatic instruments are normally used for High voltage measurements.

Description : Which of the following instruments can be used to measure AC current only? (a) Permanent Magnet Type ammeter(b) Induction type ammeter (c) Moving iron voltmeter(d) Moving iron ammeter

Last Answer : (b) Induction type ammeter

Last Answer : Jewels are used in instruments for the purpose of Bearing.

Last Answer : In the case of PMMC rectifier type instruments, the deflecting torque is proportional to Average value of AC current.

Last Answer : The electrostatic instruments can be used without serious loss of accuracy upto 100kHz frequency.

Last Answer : Integrating instruments are those which measure the total quantity of electricity delivered in a particular time.

Description : The use of _____ instruments is merely confined within laboratories as standardising instruments.

Last Answer : The use of absolute instruments is merely confined within laboratories as standardizing instruments.

Last Answer : Air friction damping is used in the instruments which is: Moving iron

Last Answer : Moving iron and PMMC instruments can be distinguished from each other by looking at: Scale

Last Answer : Commonly used instruments in power system measurement are induction.

Last Answer : Operating torques in analogue instruments are deflecting, control and damping.

Last Answer : The power factor of a single phase load can be calculated if the instruments available are three ammeters or three voltmeters.

Last Answer : The switch board instruments should be mounted in vertical position.

Last Answer : In the majority of instruments, damping is provided by eddy currents.

Last Answer : According to application, instruments are classified as switch board, portable.

Last Answer : Integrating instruments are those which measure the total quantity of electricity delivered in a particular time.

Last Answer : The use of absolute instruments is merely confined within laboratories as standardizing instruments.

Description : What do you mean by secondary instruments?

Last Answer : The instruments which will give the direct readings are called secondary instruments

Description : state properties that makes thermocouple very sensitive?

Last Answer : it measures temperatures between -250 and 1600 degree and it can measure a wider range of temperatures

Description : What is Thermocouple ?

Last Answer : : Thermocouple is a metalic bar that can be used to measure the temperature of a place. Thermocouple is an analog sensor. It is used to measure temperature. In thermocouples thermo or tharmal means ... has two terminals, one positive and the other negative. It is measured in meter voltage mode.

Description : Thermocouple How It is Work By ?

Last Answer : Thermocouple A metalic bar , whose With the help No Of space Temperature Measurement To do Goes Thermocouple a _ Analog Sensor This is it Temperature Measurement To do At work Use Is . ???? ... _ Two Terminal Stays A Positive And The other Negative. This Meters Voltage Mode To measure Is.

Description : What is the energy conversion for a thermocouple?

Last Answer : A thermocouple uses the thermoelectric effect to do what it does. Thermal energy (heat) is converted into a difference of potential, which is electric (electromagnetic) energy.

Description : The instrument used to regulate temperature to a particular degree is called : (1) Thermostat (2) Thermometer (3) Pyrometer (4) Thermocouple

Last Answer : (1) Thermostat Explanation: A thermostat is a component which senses the temperature of a system so that the system's temperature is maintained near a desired set point. At its core, a thermostat is simply the controls used to regulate temperature in a heating system.

Description : Conversion of heat into electrical er is achieved by using – (1) Ammeter (2) Hydrometer (3) Voltmeter (4) Thermocouple

Last Answer : (4) Thermocouple Explanation: Thermoelectric generators convert thermal energy into electricity by using heat from the body - or any object with a temperature gradient - as their energy source. ... energy into electricity. Bismuth telluride and its alloys are commonly used in thermocouples.

Description : The sensor connected to 'signal conditioner' (6000F125) shown in the illustration is a/an ______________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: B

Description : The sensor connected to 'signal conditioner' (6000AH170) shown in the illustration is a/an _____________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: A

Description : The sensor connected to 'signal conditioner' (6000F085) shown in the illustration is a/an ______________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: D

Description : Which sensor shown in the illustration develops its own conditioning and point setting and 'reports' directly to the 'annunciator'? EL-0094 A. Transducer B. Resistance Temperature Detector (RTD) C. Pressure Switch D. Thermocouple

Last Answer : Answer: C

Description : Which of the following devices should be used to measure the temperature of a battery electrolyte? A. Mercury thermometer B. Alcohol thermometer C. Thermocouple pyrometer D. Potentiometer

Last Answer : Answer: B

Description : Thermocouple is suitable for measuring (A) Liquid temperatures only (B) Very high temperatures only (C) Very low temperatures only (D) Both high and low temperatures

Last Answer : (D) Both high and low temperatures

Description : When a bare thermocouple is covered by a protective sheath, the response becomes (A) Faster and oscillatory (B) Faster and non-oscillatory (C) Slower and oscillatory (D) Slower and non-oscillatory

Last Answer : (D) Slower and non-oscillatory

Description : An alloy used as thermocouple material comprises of 40% nickel and60% copper. It is called (A) Constantan (B) Kanthal (C) Chromel (D) German silver

Last Answer : (A) Constantan

Description : What is the equation for resistance measurement of PT 100 thermocouple? 

Last Answer : °C = (R-100) / 0.39  

Description : State some thermocouple. 

Last Answer : Copper – constantan, Iron – constantan.  

Description : The following thermocouple may be used for measuring temperature upto 1873°K. (A) Chromel-alumel (B) Copper-constantan (C) Platinum-platinum rhodium (D) Iron-constantan

Last Answer : (C) Platinum-platinum rhodium

Description : Temperature of hot gases flowing in a pipe is measured by a thermocouple inserted in the thermal well. The thermal well made of __________ will facilitate the most accurate measurement of the temperature. (A) Copper (B) Steel (C) Aluminium (D) Brass

Last Answer : Option A

Description : Temperature of hot gases flowing in a pipe is measured by a thermocouple inserted in the thermal well. The thermal well made of __________ will facilitate the most accurate measurement of the temperature. (A) Copper (B) Steel (C) Aluminium (D) Brass

Last Answer : Option A

Description : Pressure is measured with the help of A. Manometer. C) Thermocouple. B. Ammeter. D) Orifice plate.

Last Answer : manometer

Description : What device measures infrared radiation below?  a. thermocouple  b. thermopile  c. thermodynamic device  d. thermos

Last Answer : thermopile