The field coils of D.C. generator are usually made of
(a) mica
(b) copper
(c) cast iron
(d) carbon

1 Answer

Answer :

Ans: b (b) copper

Related questions

Description : In DC generators lamination core are generally made of?

Last Answer : In DC generators lamination core are generally made of silicon steel.

Description : DC GENERATORS MCQ

Last Answer : 101. Wave winding is composed of (a) any even number of conductors (b) any odd number of conductors (c) that even number which is exact multiple of poles + 2 (d) that even number ... increase the field resistance (c) increase the speed of primemover (d) check armature insulation resis¬tance Ans: a

Description : Identify the increasing order of voltage regulation of the following dc generators a same load :  (A) differential compound, shunt and under compound  (B) shunt, differential compound and ... C) under compound, shunt and differential compound  (D) shunt, under compound and differential compound

Last Answer : Identify the increasing order of voltage regulation of the following dc generators a same load : under compound, shunt and differential compound 

Last Answer : If  equalising bar is connected to the 2 DC generators  the current will be equal in 2 generators irrespective of parallel connection so that we connect equaliser bar

Last Answer : In D.C. generators the polarity of the interpoles is the same as that of the main pole ahead.

Last Answer : For the parallel operation of two or more D.C. compound generators, we should ensure that series fields of all generators should be either on positive side or negative side of the armature.

Last Answer : Compensating windings are used in D.C. generators to neutralise the cross-magnetising effect of the armature reaction.

Last Answer : D.C. generators are connected to the busbars or disconnected from them only under the floating condition to avoid sudden loading of the primemover, to avoid mechanicaljerk to the shaft, to avoid burning of switch contacts.

Last Answer : In D.C. generators, the brushes on commutator remain in contact with conductors which lie under interpolar region.

Last Answer : In D.C. generators, current to the external circuit from armature is given through commutator commutator.

Last Answer : In D.C. generators the pole shoes are fastened to the pole core by counter sunk screws.

Last Answer : D.C. generators are installed near the load centres to reduce line losses.

Last Answer : D.C. generators are normally designed for maximum efficiency around full-load.

Description : From which material field coils of DC generator are made of?

Last Answer : Field coils of DC generator are usually made of copper.

Last Answer : In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be 8.

Last Answer : Generators for peak load plants are usually designed for maximum efficiency at 50 to 75 percent full load.

Description : The material for commutator brushes is generally (a) mica (b) copper (c) cast iron (d) carbon

Last Answer : Ans: d

Last Answer : The armature core of a D.C. generator is usually made of silicon steel.

Description : How Generators Work

Last Answer : How Generators Work Generators are devices which produce electricity. They produce electricity by converting mechanical energy from power sources. Examples would be steam, water, wind and gasoline. These ... can also be used for recreational purposes. Examples would be camping, boating or fishing.

Description : Why are generators rated in kVA not in kW ?

Last Answer : Because It's rating of generator kva is apparent power. Kw is active power which we use. And one is kvar reactive power.

Description : Two synchronous generators G1, G2 are operating in parallel and are equally sharing KVAR (Lag) component of load. To shift part of KVAR from G2 to G1, while keeping terminal voltage fixed, the following action must be done

Last Answer : Two synchronous generators G1, G2 are operating in parallel and are equally sharing KVAR (Lag) component of load. To shift part of KVAR from G2 to G1, while keeping terminal voltage fixed, the following action must be done Raise If1 and lower If2

Description : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, ... system frequency is (A) 50 Hz (B) 51 Hz (C) 51.25 Hz (D) 51.5 Hz

Last Answer : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, respectively. Then the system frequency is 50 Hz

Last Answer : Large capacity generators are invariably hydrogen cooled.

Last Answer : In a D.C. generator in case the resistance of the field winding is increased, then output voltage will decrease.

Last Answer : Flashing the field of D.C. generator means creating residual magnetism by a D.C. source.

Last Answer : In a D.C. generator, the iron losses mainly take place in armature rotor.

Description : Draw the connection diagram of long shunt differential D.C. compound generator.

Last Answer : Ans:

Description : State the function of commutator in DC generator and name the material used for commutator.

Last Answer : Function of Commutator: Commutator converts AC induced in armature winding into DC for external load. Material: i) Commutator segments are made up of Copper. ii) Commutator segments are insulated from each other by Mica.

Description : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is

Last Answer : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is 0.87

Description : The fall in speed of a dc generator due to increase in load can be corrected by  (1) cooling the armature.. (2) increasing the excitation. (3) reducing the load voltage. (4) increasing the input to the prime mover

Last Answer : It   can  be  corrected  by  increasing  the  input  to  the  prime  mover.

Description : The eddy current loss in a dc generator is 400 W at 40 Hz frequency of reversal and constant flux density. When frequency is increased to 50 Hz., eddy current loss is :  (A) 256 W (B) 320 W (C) 500 W (D) 625 W

Last Answer : The eddy current loss in a dc generator is 400 W at 40 Hz frequency of reversal and constant flux density. When frequency is increased to 50 Hz., eddy current loss is : 625 W

Description : In a DC generator the windings of interpoles are connected :  (A) in series with main field winding, to create a pole,of same polarity as the main pole ahead in the direction of rotation.  ... winding, to create a pole of opposite polarity as the main pole ahead in the direction of rotation.

Last Answer : In a DC generator the windings of interpoles are connected :  in series with the armature winding, to create a pole of same polarity as the main pole ahead in the direction of rotation. 

Description : The terminal characteristics of a dc generator suitable for electric welders is (A) separately excited generator (B) shunt generator (C) series generator (D) differentially compounded generator

Last Answer : The terminal characteristics of a dc generator suitable for electric welders is differentially compounded generator

Description : A d.c. motor can be looked upon as d.c. generator with the power flow?

Last Answer : A d.c. motor can be looked upon as d.c. generator with the power flow reversed.

Last Answer : The critical resistance of the D.C. generator is the resistance of field.

Description : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be?

Last Answer : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be zero.

Last Answer : A 220 V D.C. generator is run at full speed without any excitation. The open circuit voltage will be about 2 V.

Last Answer : In a level compounded D.C. generator, full load terminal voltage is equal to no-load terminal voltage.

Last Answer : A D.C. generator can be considered as rotating amplifier.

Last Answer : In a D.C. generator, the critical resistance refers to the resistance of field.

Last Answer : If a D.C. generator fails to build up the probable cause could not be field resistance less than the critical resistance.

Last Answer : In a D.C. generator the magnetic neutral axis coincides with the geometrical neutral axis, when there is no load on|he generator.

Last Answer : The e.m.f. generated in a D.C. generator is directly proportional to speed of armature.

Last Answer : In a D.C. generator the number of mechanical degrees and electrical degrees will be the same when number of poles is 2.

Last Answer : D.C. generator generally preferred for charging automobile batteries is long shunt compound generator.

Last Answer : In a D.C. generator the ripples in the direct e.m.f. generated are reduced by using carbon brushes of superior quality.

Last Answer : The demagnetising component of armature reaction in a D.C. generator reduces generator e.m.f.

Last Answer : If brushes of a D.C. generator are moved in order to bring these brushes in magnetic neutral axis, there will be crossmagnetisation as well as demagnetising.

Description : For a D.C. generator when the number of poles and the number of armature conductors is fixed, then which winding will give the higher e.m.f. ?

Last Answer : Wave winding