DC GENERATORS MCQ

3 Answers

Answer :

1. Laminations of core are generally made of
(a) case iron
(b) carbon
(c) silicon steel
(d) stainless steel
Ans: c
2. Which of the following could be lamina-proximately the thickness of laminations of a D.C.
machine ?
(a) 0.005 mm
(b) 0.05 mm
(c) 0.5 m
(d) 5 m
Ans: c
3. The armature of D.C. generator is laminated to
(a) reduce the bulk
(b) provide the bulk
(c) insulate the core
(d) reduce eddy current loss
Ans: d
4. The resistance of armature winding depends on
(a) length of conductor
(b) cross-sectional area of the conductor
(c) number of conductors
(d) all of the above
Ans: d
5. The field coils of D.C. generator are usually made of
(a) mica
(b) copper
(c) cast iron
(d) carbon
Ans: b
6. The commutator segments are connected to the armature conductors by means of
(a) copper lugs
(b) resistance wires
(c) insulation pads
(d) brazing
Ans: a
7. In a commutator
(a) copper is harder than mica
(b) mica and copper are equally hard
(c) mica is harder than copper
(d) none of the above
Ans: c
8. In D.C. generators the pole shoes are fastened to the pole core by
(a) rivets
(b) counter sunk screws
(c) brazing
(d) welding
Ans: b
9. According to Fleming's right-hand rule for finding the direction of induced e.m.f., when
middle finger points in the direction of induced e.m.f., forefinger will point in the direction
of
(a) motion of conductor
(b) lines of force
(c) either of the above
(d) none of the above
Ans: b
10. Fleming's right-hand rule regarding direction of induced e.m.f., correlates
(a) magnetic flux, direction of current flow and resultant force
(b) magnetic flux, direction of motion and the direction of e.m.f. induced
(c) magnetic field strength, induced voltage and current
(d) magnetic flux, direction of force and direction of motion of conductor
Ans: b
11. While applying Fleming's right-hand rule to And the direction of induced e.m.f., the
thumb points towards
(a) direction of induced e.m.f.
(b) direction of flux
(c) direction of motion of the conductor if forefinger points in the direction of generated
e.m.f.
(d) direction of motion of conductor, if forefinger points along the lines of flux
Ans: d
12. The bearings used to support the rotor shafts are generally
(a) ball bearings
(b) bush bearings
(c) magnetic bearmgs
(d) needle bearings
Ans: a
13. In D.C. generators, the cause of rapid brush wear may be
(a) severe sparking
(b) rough commutator surface
(c) imperfect contact
(d) any of the above
Ans: d
14. In lap winding, the number of brushes is always
(a) double the number of poles
(b) same as the number of poles
(c) half the number of poles
(d) two
Ans: b
15. For a D.C. generator when the number of poles and the number of armature conductors
is fixed, then which winding will give the higher e.m.f. ?
(a) Lap winding
(b) Wave winding
(c) Either of (a) and (b) above
(d) Depends on other features of design
Ans: b
16. In a four-pole D.C. machine
(a) all the four poles are north poles
(b) alternate poles are north and south
(c) all the four poles are south poles
(d) two north poles follow two south poles
Ans: b
17. Copper brushes in D.C. machine are used
(a) where low voltage and high currents are involved
(b) where high voltage and small cur-rents are involved
(c) in both of the above cases
(d) in none of the above cases
Ans: a
18. A separately excited generator as compared to a self-excited generator
(a) is amenable to better voltage con-trol
(b) is more stable
(c) has exciting current independent of load current
(d) has all above features
Ans: d
19. In case of D.C. machines, mechanical losses are primary function of
(a) current
(b) voltage
(c) speed
(d) none of above
Ans: c
20. Iron losses in a D.C. machine are independent of variations in
(a) speed
(b) load
(c) voltage
(d) speed and voltage
Ans: b
21. In D.C. generators, current to the external circuit from armature is given through
(a) commutator
(b) solid connection
(c) slip rings
(d) none of above
Ans: a
23. Brushes of D.C. machines are made of
(a) carbon
(b) soft copper
(c) hard copper
(d) all of above
Ans: a
24. If B is the flux density, I the length of conductor and v the velocity of conductor, then
induced e.m.f. is given by
(a)Blv
(b)Blv2
(c)Bl2v
(d)Bl2v2
Ans: a
25. In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen
coils, the pole pitch will be
(a) 4
(b) 8
(c) 16
(d) 32
Ans: b
26. The material for commutator brushes is generally
(a) mica
(b) copper
(c) cast iron
(d) carbon
Ans: d
27. The insulating material used between the commutator segments is normally
(a) graphite
(b) paper
(c) mica
(d) insulating varnish
Ans: c
28. In D.C. generators, the brushes on commutator remain in contact with conductors
which
(a) lie under south pole
(b) lie under north pole
(c) lie under interpolar region
(d) are farthest from the poles
Ans: c
29. If brushes of a D.C. generator are moved in order to bring these brushes in magnetic
neutral axis, there will be
(a) demagnetisation only
(b) cross magnetisation as well as magnetisation
(c) crossmagnetisation as well as demagnetising
(d) cross magnetisation only
Ans: c
30. Armature reaction of an unsaturated D.C. machine is
(a) crossmagnetising
(b) demagnetising
(c) magnetising
(d) none of above
Ans: a
31. D.C. generators are connected to the busbars or disconnected from them only under the
floating condition
(a) to avoid sudden loading of the primemover
(b) to avoid mechanicaljerk to the shaft
(c) to avoid burning of switch contacts
(d) all above
Ans: d
32. Eddy currents are induced in the pole shoes of a D.C. machine due to
(a) oscillating magnetic field
(b) pulsating magnetic flux
(c) relative rotation between field and armature
(d) all above
Ans: c
33. In a D.C. machine, short-circuited field coil will result in
(a) odour of barning insulation
(b) unbalanced magnetic pull producing vibrations
(c) reduction of generated voltage for which excitation has to be increased to maintain the
voltage
(d) all above
Ans:
34. Equilizer rings are required in case armature is
(a) wave wound
(b) lap wound
(c) delta wound
(d) duplex wound
Ans: b
35. Welding generator will have
(a) lap winding
(b) wave winding
(c) delta winding
(d) duplex wave winding
Ans: a
36. In case of D.C. machine winding, number of commutator segments is equal to
(a) number of armature coils
(b) number of armature coil sides
(c) number of armature conductors
(d) number of armature turns
Ans: a
37. For a D.C. machines laboratory following type of D.C. supply will be suitable
(a) rotary converter
(b) mercury are rectifier
(c) induction motor D.C. generator set
(d) synchronous motor D.C. generator set
Ans: c
38. The function of pole shoes in the case of D.C. machine is
(a) to reduce the reluctance of the magnetic path
(b) to spread out the flux to achieve uniform flux density
(c) to support the field coil
(d) to discharge all the above functions
Ans: d
39. In the case of lap winding resultant pitch is
(a) multiplication of front and back pitches
(b) division of front pitch by back pitch
(c) sum of front and back pitches
(d) difference of front and back pitches
Ans: d
40. A D.C. welding generator has
(a) lap winding
(b) wave moving
(c) duplex winding
(d) any of the above
Ans: a
41. Which of the following statement about D.C. generators is false ?
(a) Compensating winding in a D.C. machine helps in commutation
(b) In a D. C. generator interpoles winding is connected in series with the armature
winding
(c) Back pitch and front pitch are both odd and approximately equal to the pole pitch
(d) Equilizing bus bars are used with parallel running of D.C. shunt generators
Ans: d
42. The demagnetising component of armature reaction in a D.C. generator
(a) reduces generator e.m.f.
(b) increases armature speed
(c) reduces interpoles flux density
(d) results in sparking trouble
Ans: a
43. Magnetic field in a D.C. generator is produced by
(a) electromagnets
(b) permanent magnets
(c) both (a) and (b)
(d) none of the above
Ans: a
44. The number of brushes in a commutator depends on
(a) speed of armature
(b) type of winding
(c) voltage
(d) amount of current to be collected
Ans: d
45. Compensating windings are used in D.C. generators
(a) mainly to reduce the eddy currents by providing local short-circuits
(b) to provide path for the circulation of cooling air
(c) to neutralise the cross-magnetising effect of the armature reaction
(d) none of the above
Ans: c
46. Which of the following components of a D.C, generator plays vital role for providing
direct current of a D.C. generator ?
(a) Dummy coils
(b) Commutator
(c) Eye bolt
(d) Equilizer rings
Ans: b
47. In a D.C. generator the ripples in the direct e.m.f. generated are reduced by
(a) using conductor of annealed copper
(b) using commutator with large number of segments
(c) using carbon brushes of superior quality
(d) using equiliser rings
Ans: c
48. In D.C. generators, lap winding is used for
(a) high voltage, high current
(b) low voltage, high current
(c) high voltage, low current
(d) low voltage, low current
Ans: b
49. Two generators A and B have 6-poles each. Generator A has wave wound armature
while generator B has lap wound armature. The ratio of the induced e.m.f. is generator A
and B will be
(a) 2 : 3
(b) 3 : 1
(c) 3 : 2
(d) 1 : 3
Ans: b
50. The voltage drop for which of the following types of brush can be expected to be least ?
(a) Graphite brushes
(b) Carbon brushes
(c) Metal graphite brushes
(d) None of the above
Ans: c

Answer :

51. The e.m.f. generated by a shunt wound D.C. generator isE. Now while pole flux remains
constant, if the speed of the generator is doubled, the e.m.f. generated will be
(a) E/2
(b) 2E
(c) slightly less than E
(d) E
Ans: b
52. In a D.C. generator the actual flux distribution depends upon
(a) size of air gap
(b) shape of the pole shoe
(c) clearance between tips of the ad¬jacent pole shoes
(d) all of the above
Ans:
53. The armature core of a D.C. generator is usually made of
(a) silicon steel
(b) copper
(c) non-ferrous material
(d) cast-iron
Ans: a
9.63. Satisfactory commutation of D.C. machines requires
(a) brushes should be of proper grade and size
(b) brushes should smoothly run in the holders
(c) smooth, concentric commutator properly undercut
(d) all of the above
Ans: d
54. Open circuited armature coil of a D.C. machine is
(a) identified by the scarring of the commutator segment to which open circuited coil is
connected
(b) indicated by a spark completely around the commutator
(c) both (a) and (b)
(d) none of the above
Ans: c
55. In a D.C. machine, fractional pitch winding is used
(a) to increase the generated voltage
(b) to reduce sparking
(c) to save the copper because of shorter end connections
(d) due to (b) and (c) above
Ans:
56. For the parallel operation of two or more D.C. compound generators, we should ensure
that
(a) voltage of the incoming generator should be same as that of bus bar
(b) polarity of incoming generator should be same as that of bus bar
(c) all the series fields should be run in parallel by means of equilizer connection
(d) series fields of all generators should be either on positive side or negative side of the
armature
(e) all conditions mentioned above should be satisfied
Ans: d
57. D.C. series generator is used
(a) to supply traction load
(b) to supply industrial load at constant voltage
(c) voltage at the toad end of the feeder
(d) for none of the above purpose
Ans: c
58. Following D.C. generator will be in a position to build up without any residual
magnetism in the poles
(a) series generator
(b) shunt generator
(c) compound generator
(d) self-excited generator
Ans: d
59. Interpole flux should be sufficient to
(a) neutralise the commutating self induced e.m.f.
(b) neutralise the armature reaction flux
(c) neutralise both the armature reaction flux as well as commutating e.m.f. induced in the
coil
(d) perform none of the above functions
Ans: c
60. D.C. generator generally preferred for charging automobile batteries is
(a) series generator
(b) shunt generator
(c) long shunt compound generator
(d) any of'the above
Ans: c
61. In a D.C. generator the number of mechanical degrees and electrical degrees will be the
same when
(a) r.p.m. is more than 300
(b) r.p.m. is less than 300
(c) number of poles is 4
(d) number of poles is 2
Ans: d
62. Permeance is the reciprocal of
(a) flux density
(b) reluctance
(c) ampere-turns
(d) resistance
Ans: b
63. In D.C. generators the polarity of the interpoles
(a) is the same as that of the main pole ahead
(b) is the same as that of the immediately preceding pole
(c) is opposite to that of the main pole ahead
(d) is neutral as these poles do not play part in generating e.m.f.
Ans: a
64. The e.m.f. generated in a D.C. generator is directly proportional to
(a) flux/pole
(b) speed of armature
(c) number of poles
(d) all of the above
Ans: b
65. In a D.C. generator the magnetic neutral axis coincides with the geometrical neutral
axis, when
(a) there is no load on|he generator
(b) the generator runs on full load
(c) the generator runs on overload
(d) the generator runs on designed speed
Ans: a
66. In a D.C. generator in order to reduce sparking at brushes, the self-induced e.m.f. in the
coil is neutralised by all of the following except
(a) interpoles
(b) dummy coils
(c) compensating winding
(d) shifting of axis of brushes
Ans: b
67. In D.C. generators on no-load, the air gap flux distribution in space is
(a) sinusoidal
(b) triangular
(c) pulsating
(d) flat topped
Ans: d
68. A shunt generator running at 1000 r.p.m. has generated e.m.f. as 200 V. If the speed
increases to 1200 r.p.m., the generated e.m.f. will be nearly
(a) 150 V
(b) 175 V
(c) 240 V
(d) 290 V
Ans: c
69. The purpose of providing dummy coils in a generator is
(a) to reduce eddy current losses
(b) to enhance flux density
(c) to amplify voltage
(d) to provide mechanical balance for the rotor
Ans: d
70. In a shunt generator the voltage build up is generally restricted by
(a) speed limitation
(b) armature heating
(c) insulation restrictions
(d) saturation of iron
Ans:
71. If a D.C. generator fails to build up the probable cause could not be
(a) imperfect brush contact
(b) field resistance less than the critical resistance
(c) no residual magnetism in the generator
(d) faulty shunt connections tending to reduce the residual magnetism
Ans: b
72. Flashing the field of D.C. generator means
(a) neutralising residual magnetism
(b) creating residual magnetism by a D.C. source
(c) making the magnetic losses of forces parallel
(d) increasing flux density by adding extra turns of windings on poles
Ans: b
73. The e.m.f. induced in the armature of a shunt generator is 600 V. The armature
resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be
(a) 640 V
(b) 620 V
(c) 600 V
(d) 580 V
Ans: d
74. In a D.C. generator the critical resistance refers to the resistance of
(a) brushes
(b) field
(c) armature
(d) load
Ans: b
75. To achieve sparkless commutation brushes of a D.C. generator are rockedm ahead so as
to bring them
(a) just ahead of magnetic neutral axis
(b) in magnetic neutral axis
(c) just behind the magnetic neutral axis
Ans: a
76. Armature coil is short circuited by brushes when it lies
(a) along neutral axis
(b) along field axis
(c) in any of the above positions
(d) in none of the above positions
Ans: a
77. A cumulatively compounded long shunt generator when operating as a motor would be
(a) cumulatively compounded long shunt
(b) differentially compounded long shunt
(c) cumulatively compounded short shunt
(d) differentially compounded short shunt
Ans: b
78. To avoid formation of grooves in the commutator of a D.C. machine
(a) the brushes of opposite polarity should track each other
(b) the brushes of same polarity should track each other
(c) brush position has no effect on the commutator grooving
Ans: a
79. The following constitute short-circuit in the armature winding.
(a) Insulation failure between two com-mutator bars
(6) Insulation failure between two turns of a coil
(c) Two of more turns of the same coil getting grounded
(d) All of the above
Ans: d
80. The rapid wear of brushes takes place due to
(a) abrasion from dust
(b) excessive spring pressure
(c) rough commutator bars
(d) high mica insulation between com-mutation bars
(e) all of the above factors
Ans: e
81. Number of tappings for each equilizer ring is equal to
(a) number of pole pairs
(b) number of poles
(c) number of parallel paths
(d) number of commutator segments
Ans: a
82. A D.C. generator can be considered as
(a) rectifier
(b) primemover
(c) rotating amplifier
(d) power pump
Ans: c
83. In any rotating machine that part which houses the conductors and in which e.m.f.
induced is to be utilised is called
(a) rotor
(b) stator
(c) field
(d) armature
Ans: d
84. In a D.C. machine stray loss is the sum of
(a) total copper loss and mechanical loss
(b) armature copper loss and iron loss
(c) shunt field copper loss and mechanical loss
(d) iron loss and mechanical loss
Ans: d
85. Lap winding is composed of
(a) any even number of conductors
(b) any odd number of conductors
(c) that even number which is exact multiple of poles + 2
(d) that even number which is exact multiple of poles
Ans: a
86. In a D.C. generator in case the resistance of the field winding is increased, then output
voltage will
(a) increase
(b) decrease
(c) remain unaffected
(d) fluctuate heavily
Ans: b
87. An exciter for a turbo generator is a
(a) separately excited generator
(b) shunt generator
(c) series generator
(d) compound generator
Ans: b
88. In case of a flat compounded generator
(a) voltage generated is less than the rated voltage
(b) generated voltage is proportional to the load on the generator
(c) voltage remains constant irrespec¬tive of the load
(d) speed varies in proportion to the load on the generator
Ans: c
89. Which of the following generator will have negligible terminal voltage while running on
no-load ?
(a) Series generator
(b) Shunt generator
(c) Compound generator
(d) Separately excited generator
Ans: a
90. Which of the following D.C. generators will be in a position to build up without any
residual magnetism in the poles ?
(a) Series generator
(b) Shunt generator
(c) Compound generator
(d) None of the above
Ans: d
91. In over compounded generator, full load terminal voltage is
(a) almost zero
(b) less than noload terminal voltage
(c) more than noload terminal voltage
(d) equal to no-load terminal voltage
Ans: c
92. In a level compounded D.C. generator, full load terminal voltage is
(a) negligibly low
(b) equal to no-load terminal voltage
(c) more than no-load terminal voltage
(d) less than no-load terminal voltage
Ans: b
93. The terminal voltage of a D.C. shunt generator drops on load because of all of the
following reasons except
(a) armature reaction
(b) armature resistance drop
(c) field weakening due to armature reaction and armature
(d) commutation
Ans: d
94. In a D.C. generator
(a) external resistance = internal char-acteristic - armature reaction
(b) internal characteristic = magnetisation characteristic - ohmic drop
(c) external characteristic = magnetisation characteristic - ohmic drop - armature reaction
(d) magnetisation characteristic = external characteristic
Ans: c
95. A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature
voltage wave
(a) will be zero
(b) will be of 5 Hz
(c) willbeof5xiVHz
(d) will be of v Hz 5
Ans: b
96. A 220 V D.C. generator is run at full speed without any excitation. The open circuit
voltage will be
(a) zero
(b) about 2 V
(c) about 50 V
(d) 220 V
Ans: b
97. In a separately excited generator supplying rated load the armature reaction ,
(a) is always present
(b) is always absent
(c) may be sometimes present
(d) none of the above
Ans: a
98. If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will
be
(a) zero
(b) small
(c) the same as rated voltage
(d) high
Ans: a
99. Armature reaction in a generator results in
(a) demagnetisation of leading pole tip and magnetisation of trailing pole tip
(b) demagnetisation of trailing pole tip and magnetisation of leading pole tip
(c) damagnetising the centre of all poles
(d) magnetising the centre of all poles
Ans: a
100. Following energized winding of a D.C. machine should not be opened as it would
produce high inductive voltage which may be dangerous to personnel and may cause its
own insulation failure.
(a) Series field
(b) Compensating field
(c) Inter pole field
(d) Shunt field
Ans: d

Answer :

101. Wave winding is composed of
(a) any even number of conductors
(b) any odd number of conductors
(c) that even number which is exact multiple of poles + 2
(d) that even number which is exact multiple of poles
Ans: c
102. The critical resistance of the D.C. generator is the resistance of
(a) field
(b) brushes
(c) armature
(d) load
Ans: a
103. When two D.C. series generators are running in parallel, an equilizer bar is used
(a) to increase the speed and hence generated e.m.f.
(b) to increase the series flux
(c) so that two similar machines will pass approximately equal currents to the load
(d) to reduce the combined effect of ar-mature reaction of both machines
Ans: c
104. Which of the following generating machine will offer constant voltage on all loads ?
(a) Self-excited generator
(b) Separately excited generator
(c) Level compounded generator .
(d) All of the above
Ans: c
105. Which of the following generators will be preferred if they are required to be run in
parallel ?
(a) Shunt generators
(b) Series generators
(c) Compound generators
(d) None of the above
Ans: a
106. Two generators are running in parallel. One of the generators may run as motor for
which of the following reasons ?
(a) The direction of that generator is reversed
(b) The speed of that generator is increased
(c) The field of that generator is weakened
(d) That generator takes large share of loads
Ans: d
107. A D.C. generator works on the principle of
(a) Lenz's law
(b) Ohm's law
(c) Faraday's law of electromagnetic induction
(d) none of the above
Ans: c
108. A series generator can self-excite
(a) only if the load current is zero
(b) only if the load current is not zero
(c) irrespective of the value of load current
(d) none of the above
Ans: b
109. A shunt generator can self-excite
(a) only if the resistance of the field circuit is less than critical value
(b) only if the resistance of the field circuit is greater than critical value
(c) irrespective of the value of the resis-tance in the field circuit
Ans: a
110. The terminal voltage of a series generator is 150 V when the load current is 5 A. If the
load current is increased to 10 A, the terminal voltage will be
(a) 150 V
(b) less than 150 V
(c) greater than 150 V
(d) none of the above
Ans: c
111. The open circuit voltage of a compound generator is 250 V. At full load the terminal
voltage
(a) will be less than 250 V
(b) will always be 250 V
(c) may be greater or less than 250 V
(d) none of the above
Ans: c
112. Two D.C. shunt generators, each with armature resistance of 0.02 ohm and field
resistance of 50 ohm run in parallel and supply a total current of 1000 amperes to the load
circuit. If their e.m.fs. are 270 V and 265 V, their bus bar voltage will be
(a) 270 V
(b) 267.5 V
(c) 265 V
(d) 257.4 V
Ans: b
113. The essential condition for parallel operation of two D.C. generators is that they have
'(a) same kW rating
(b) the same operation r.p.m.
(c) the same drooping voltage charac-teristics
(d) same percentage regulation
Ans: c
114. When two D.C. generators are running in parallel an equilizer bar is used
(a) to increase the series flux
(b) to increase the generated e.m.f.
(c) to reduce the combined effect of ar-mature reaction of both the machines
(d) so that the two identical machines will pass approximately equal currents to the load
Ans: d
115. With a D.C. generator which of the following regulation is preferred ?
(a) 100% regulation
(b) infinite regulation
(c) 50% regulation
(d) 1% regulation
Ans: d
116. Which generator would you prefer for feeding long D.C. transmission lines ?
(a) Series generator
(b) Shunt generator
(c) Over compound generator
(d) Flat compound generator
Ans: c
117. In a D.C. generator the critical resistance can be increased by
(a) increasing its field resistance
(b) decreasing its field resistance
(c) increasing its speed
(d) decreasing its speed
Ans: c
118. The number of armature parallel paths in a two-pole D.C. generator having duplex lap
winding is
(a) 2
(b) 4
(c) 6
(d) 8
Ans: b
119. For both lap and wave windings, there are as many commutator bars as the number of
(a) slots
(b) armature conductors
(c) winding elements
(d) poles
Ans: c
120. The series field of a short-shunt D.C. generator is excited by
(a) external current
(b) armature current
(c) shunt current
(d) load current
Ans: d
121. As a result of armature reaction, the reduction in the total mutual air gap flux in a D.C.
generator is approximately
(a) 40 percent
(b) 25 percent
(c) 10 percent
(d) 5 percent
Ans: d
122. Shunt generators are most suited for stable parallel operation because of their
(a) rising voltage characteristics
(b) identical voltage characteristics
(c) drooping voltage characteristics
(d) linear voltage characteristics
Ans: c
123. The main factor which leads to unstable parallel operation of flat and over
compounded generators is
(a) their rising voltage characteristics
(b) unequal number of turns in their series field windings
(c) unequal speed regulation of their primemovers
(d) unequal series field resistances
Ans: a
124. If a self excited D.C. generator after being installed, fails to build up on its first trial run,
the first thing to do is to
(a) reverse the field connections
(b) increase the field resistance
(c) increase the speed of primemover
(d) check armature insulation resis¬tance
Ans: a

Related questions

Description : DC MOTOR MCQ

Last Answer : 101. Which of the following loss in a D.C. generator is dissipated in the form of heat? (a) Mechanical loss (b) Core loss (c) Copper loss (d) All of the above Ans: d 102. Which of the following ... (b) does not run as a generator (c) also runs as a motor comes to stop after sometime Ans: a

Description : Identify the increasing order of voltage regulation of the following dc generators a same load :  (A) differential compound, shunt and under compound  (B) shunt, differential compound and ... C) under compound, shunt and differential compound  (D) shunt, under compound and differential compound

Last Answer : Identify the increasing order of voltage regulation of the following dc generators a same load : under compound, shunt and differential compound 

Description : In DC generators lamination core are generally made of?

Last Answer : In DC generators lamination core are generally made of silicon steel.

Last Answer : If  equalising bar is connected to the 2 DC generators  the current will be equal in 2 generators irrespective of parallel connection so that we connect equaliser bar

Last Answer : In D.C. generators the polarity of the interpoles is the same as that of the main pole ahead.

Last Answer : For the parallel operation of two or more D.C. compound generators, we should ensure that series fields of all generators should be either on positive side or negative side of the armature.

Last Answer : Compensating windings are used in D.C. generators to neutralise the cross-magnetising effect of the armature reaction.

Last Answer : D.C. generators are connected to the busbars or disconnected from them only under the floating condition to avoid sudden loading of the primemover, to avoid mechanicaljerk to the shaft, to avoid burning of switch contacts.

Last Answer : In D.C. generators, the brushes on commutator remain in contact with conductors which lie under interpolar region.

Last Answer : In D.C. generators, current to the external circuit from armature is given through commutator commutator.

Last Answer : In D.C. generators the pole shoes are fastened to the pole core by counter sunk screws.

Last Answer : D.C. generators are installed near the load centres to reduce line losses.

Last Answer : D.C. generators are normally designed for maximum efficiency around full-load.

Description : The field coils of D.C. generator are usually made of (a) mica (b) copper (c) cast iron (d) carbon

Last Answer : Ans: b (b) copper

Description : TRANSMISSION AND DISTRIBUTION MCQ

Last Answer : 51. It is difficult to maintain oil filled cables. (a) Yes (b) No Ans: a 51. In capacitance grading a homogeneous dielectric is used. (a) Yes (b) No Ans: b 52. In congested areas where excavation is ... The metallic sheath may be made of lead or lead alloy or of aluminium. (a) Yes (b) No Ans: b

Description : SYNCHRONOUS MOTORS MCQ

Last Answer : 101. In a synchronous motor it the back e.m.f. generated in the armature at noload is approximately equal to the applied voltage, then (a) the motor is said to be fully loaded (b) the torque ... square of the applied voltage (c) inversely proportional to applied voltage (d) none of the above Ans: a

Description : SINGLE PHASE INDUCTION MOTORS MCQ

Last Answer : 101. After the starting winding of a single phase induction motor is disconnected from supply, it continues to run only on (a) running winding (b) rotor winding (c) field winding (d) compensating winding Ans: a ... motor is usually reduced by using (a) gearing (b) belts (c) brakes (d) chains Ans: a

Description : THREE PHASE INDUCTION MOTORS MCQ

Last Answer : 101. Insertion of resistance in the stator of an induction motor (a) increases the load torque (b) decreases the starting torque (c) increases the starting torque (d) none of the above Ans: b

Description : TRANSFORMERS MCQ

Last Answer : 101. A shell-type transformer has (a) high eddy current losses (b) reduced magnetic leakage (c) negligibly hysteresis losses (d) none of the above Ans: b 102. A transformer can have regulation closer to zero (a ... (6) much smaller (c) much higher (d) somewhat smaller (e) none of the above Ans: c

Description : Power Maintenance MCQ

Last Answer : 1) Turbine pumps are used up to a suction head of ( b ) a. 1000 ft. c. 20 ft b. 100 ft d. 50 ft 2) The yard stick for provision of Electrical points in staff quarters can be changed by the Zonal railways ... is used for electrical fire ( b ) a. Water c. Foam b. Co2 & dry powder d. None of the above

Description : MCQ on Motor Control Center

Last Answer : 1. MCC stands for ______ a. Motor Control Center b. Motor Control Cost c. Machine Components Center d. None of the above Answer : a. Motor Control Center 2. MCC contains _____ a. Fuse b. MCB c. ... a) Start the motor b) Accelerate the motor c) Decelerate the motor d) Stop the motor Answer : a

Description : How Generators Work

Last Answer : How Generators Work Generators are devices which produce electricity. They produce electricity by converting mechanical energy from power sources. Examples would be steam, water, wind and gasoline. These ... can also be used for recreational purposes. Examples would be camping, boating or fishing.

Description : Why are generators rated in kVA not in kW ?

Last Answer : Because It's rating of generator kva is apparent power. Kw is active power which we use. And one is kvar reactive power.

Description : Two synchronous generators G1, G2 are operating in parallel and are equally sharing KVAR (Lag) component of load. To shift part of KVAR from G2 to G1, while keeping terminal voltage fixed, the following action must be done

Last Answer : Two synchronous generators G1, G2 are operating in parallel and are equally sharing KVAR (Lag) component of load. To shift part of KVAR from G2 to G1, while keeping terminal voltage fixed, the following action must be done Raise If1 and lower If2

Description : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, ... system frequency is (A) 50 Hz (B) 51 Hz (C) 51.25 Hz (D) 51.5 Hz

Last Answer : Two synchronous generators operating in parallel supply a common load of 2.5 MW. The frequency-power characteristics have a common slope of 1 MW/Hz and the no-load frequencies of the generators are 51.5 Hz and 51.0 Hz, respectively. Then the system frequency is 50 Hz

Last Answer : Large capacity generators are invariably hydrogen cooled.

Last Answer : Generators for peak load plants are usually designed for maximum efficiency at 50 to 75 percent full load.

Last Answer : In D.C. generators on no-load, the air gap flux distribution in space is flat topped.

Description : What is DC ?

Last Answer : Ans. It is a unidirectional current which changes its magnitude but not the directions.

Description : State at least one function and the material used for the following parts of DC Motor.

Last Answer : Part Function Material Yoke -Provides mechanical support for poles -Acts as protecting cover for machine -Provides path for magnetic flux Cast Iron OR Cast Steel Field Winding - ... Pole core  Provides mechanical support to field winding. Cast Iron OR Cast Steel

Description : Write about transformer on DC.

Last Answer : Transformer on DC : Transformer cannot work on DC. Transformer works on electromagnetic induction principle. Electromagnetic induction principle means when flux linking with coil changes and EMF induced in it ... winding insulation will burn. https://youtu.be/TVp_0fIfxqY

Description : State the modification to be done in dc series motor to work satisfactorily as ac series motor. State applications of ac series motor.

Last Answer : Modifications are necessary in a dc series motor so that it operates satisfactorily on ac supply. The modifications are as follows:  1) AC series motor is built with a few field turns as ... and grinders 5) High speed vacuum cleaners 6) Sewing machines 7) Food processors 8) Drilling machine 

Description : Compare the AC and DC Arc lamps.

Last Answer : AC Arc Lamp DC Arc Lamp Cross section area of electrode is same Cross section area of electrode is positive rod is twice that of negative rod Series inductor is used for stability ... supply is used for DC arc lamp Luminous efficiency is less Luminous efficiency is high

Description : Why poles of dc machine are laminated?

Last Answer : Poles of DC machines are laminated to reduce the eddy current losses in the poles.

Description : DC motor gross torque example

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : DC shunt motor

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : DC motor brake test numerical

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : Brake test on DC series motor

Last Answer : .embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }

Description : Direct Current (DC) Next Topic : Alternating current (AC)

Last Answer : Direct Current (DC) is the unidirectional electric current. Uni meaning is one. And the flow of charge in same direction. We know that conventional current flow from positive terminal of battery to ... The magnitude of DC may constant or vary but direction do not change with respect to time.

Last Answer : Copper losses,iron losses,variable losses , constant losees

Description : Why are DC motors used in trains and not AC motors ?

Last Answer : The reason is torque. torque is inversely proportional to speed..i.e when th knowe train comes to rest position to motion.. initial speed is zero..so it requires high starting torque for ... current will flow through field and armature coils then maximum torque is available at the intial condition.

Description : Why is AC considered more efficient than DC?

Last Answer : Ac is more efficient than dc because it is easy to maintain and change the voltage of ac for transmission and distribution purpose. Plant cost of ac transmission is much lower compared to dc transmission. When fault occurs it is easy to interrupt ac supply.

Description : Which is more dangerous AC or DC and why ?

Last Answer : Dc is more dangerous than Ac because in Ac the voltage  will varies but in dc the constant voltage 

Description : Limitation and application of High Voltage DC (HVDC)

Last Answer : Limitation and application of High Voltage DC (HVDC) :  Limitation:- 1) It is difficult to step up and step down DC voltage like AC voltage. 2) Special cooling ... conventional/non-conventional) 12) Increasing existing grid utilization. 13) Interconnection of different grids or networks

Description : If field current is decreased in shunt dc motor, the speed of the motor (a) remains same. (b) increases. (c) decreases. (d) none of the above.

Last Answer : increases

Description : Define: i) Q point ii) DC loadline iii) Need of biasing iv) Current gain

Last Answer : i) Q point: It is the point on the load line which represents the dc current through a transistor (ICQ) and the voltage across it (VCEQ), when no ac signal is applied.  ii) DC load line: The ... region is as desired.  iv) Current Gain: It is a ratio of output current to input current.

Description : What would happen if a DC motor was supplied with AC ?

Last Answer : With three phase induction motor, humming and not rotate, but if single phase universal motor like air blower, home mixture, motor run on constant speed..speed variation not possible...

Description : What is the conversion between. AC to AC ? DC to DC? AC to DC? DC to AC ?

Last Answer : 1.ac to ac is regulation 2.dc to dc is chopper 3.ac to dc is rectifier 4.dc to ac is inverter

Description : State the function of following parts of DC motor : i) Yoke ii) Poles iii) Field winding iv) Commutator. 

Last Answer : Function : i) Yoke: The yoke serves the following two purposes. i) It supports the other components such as poles and provides mechanical protection for whole machine. ii) It forms a part of ... one pole to another and thus to help the motor to develop a continuous and unidirectional torque  

Description : Explain concept of back emf in DC machine. State how it governs armature current. 

Last Answer : Back emf: When the armature of DC machine rotates under the influence of driving torque, the armature conductors move in the magnetic field and cut it and hence emf is induced in them. The ... flow of armature current i.e. it automatically changes the armature current to meet load requirements.