TRANSFORMERS MCQ

3 Answers

Answer :

1. Which of the following does not change in a transformer ?
(a) Current
(b) Voltage
(c) Frequency
(d) All of the above
Ans: c
2. In a transformer the energy is conveyed from primary to secondary
(a) through cooling coil
(b) through air
(c) by the flux
(d) none of the above
Ans: c
3. A transformer core is laminated to
(a) reduce hysteresis loss
(b) reduce eddy current losses
(c) reduce copper losses
(d) reduce all above losses
Ans: b
4. The degree of mechanical vibrations produced by the laminations of a transformer
depends on
(a) tightness of clamping
(b) gauge of laminations
(c) size of laminations
(d) all of the above
Ans: d
5. The no-load current drawn by transformer is usually what per cent of the full-load
current ?
(a) 0.2 to 0.5 per cent
(b) 2 to 5 per cent
(c) 12 to 15 per cent
(d) 20 to 30 per cent
Ans: b
6. The path of a magnetic flux in a transformer should have
(a) high resistance
(b) high reluctance
(c) low resistance
(d) low reluctance
Ans: d
7. No-load on a transformer is carried out to determine
(a) copper loss
(b) magnetising current
(c) magnetising current and loss
(d) efficiency of the transformer
Ans: c
8. The dielectric strength of transformer oil is expected to be
(a) lkV
(b) 33 kV
(c) 100 kV
(d) 330 kV
Ans: b
9. Sumpner's test is conducted on trans-formers to determine
(a) temperature
(b) stray losses
(c) all-day efficiency
(d) none of the above
Ans: a
10. The permissible flux density in case of cold rolled grain oriented steel is around
(a) 1.7 Wb/m2
(b) 2.7 Wb/m2
(c) 3.7 Wb/m2
(d) 4.7 Wb/m2
Ans: a
The efficiency of a transformer will be maximum when
(a) copper losses = hysteresis losses
(b) hysteresis losses = eddy current losses
(c) eddy current losses = copper losses
(d) copper losses = iron losses
Ans: d
12. No-load current in a transformer
(a) lags behind the voltage by about 75°
(b) leads the voltage by about 75°
(c) lags behind the voltage by about 15°
(d) leads the voltage by about 15°
Ans: a
13. The purpose of providing an iron core in a transformer is to
(a) provide support to windings
(b) reduce hysteresis loss
(c) decrease the reluctance of the magnetic path
(d) reduce eddy current losses
Ans: c
14. Which of the following is not a part of transformer installation ?
(a) Conservator
(b) Breather
(c) Buchholz relay
(d) Exciter
Ans: d
15. While conducting short-circuit test on a transformer the following side is short
circuited
(a) High voltage side
(b) Low voltage side
(c) Primary side
(d) Secondary side
Ans: b
16. In the transformer following winding has got more cross-sectional area
(a) Low voltage winding
(b) High voltage winding
(c) Primary winding
(d) Secondary winding
Ans: a
17. A transformer transforms
(a) voltage
(b) current
(c) power
(d) frequency
Ans: c
18. A transformer cannot raise or lower the voltage of a D.C. supply because
(a) there is no need to change the D.C. voltage
(b) a D.C. circuit has more losses
(c) Faraday's laws of electromagnetic induction are not valid since the rate of change of flux
is zero
(d) none of the above
Ans: c
19. Primary winding of a transformer
(a) is always a low voltage winding
(b) is always a high voltage winding
(c) could either be a low voltage or high voltage winding
(d) none of the above
Ans: c
20. Which winding in a transformer has more number of turns ?
(a) Low voltage winding
(b) High voltage winding
(c) Primary winding
(d) Secondary winding
Ans: b
21. Efficiency of a power transformer is of the order of
(a) 100 per cent
(b) 98 per cent
(c) 50 per cent
(d) 25 per cent
Ans: b
22. In a given transformer for given applied voltage, losses which remain constant
irrespective of load changes are
(a) friction and windage losses
(b) copper losses
(c) hysteresis and eddy current losses
(d) none of the above
Ans: c
23. A common method of cooling a power transformer is
(a) natural air cooling
(b) air blast cooling
(c) oil cooling
(d) any of the above
Ans: c
24. The no load current in a transformer lags behind the applied voltage by an angle of
about
(a) 180°
(b) 120"
(c) 90°
(d) 75°
Ans: d
25. In a transformer routine efficiency depends upon
(a) supply frequency
(b) load current
(c) power factor of load
(d) both (b) and (c)
Ans: d
26. In the transformer the function of a conservator is to
(a) provide fresh air for cooling the transformer
(b) supply cooling oil to transformer in time of need
(c) protect the transformer from damage when oil expends due to heating
(d) none of the above
Ans: c
27. Natural oil cooling is used for transformers upto a rating of
(a) 3000 kVA
(b) 1000 kVA
(c) 500 kVA
(d) 250 kVA
Ans: a
28. Power transformers are designed to have maximum efficiency at
(a) nearly full load
(b) 70% full load
(c) 50% full load
(d) no load
Ans: a
29. The maximum efficiency of a distribution transformer is
(a) at no load
(b) at 50% full load
(c) at 80% full load
(d) at full load
Ans: b
30. Transformer breaths in when
(a) load on it increases
(b) load on it decreases
(c) load remains constant
(d) none of the above
Ans: b
31. No-load current of a transformer has
(a) has high magnitude and low power factor
(b) has high magnitude and high power factor
(c) has small magnitude and high power factor
(d) has small magnitude and low power factor
Ans: d
32. Spacers are provided between adjacent coils
(a) to provide free passage to the cool¬ing oil
(b) to insulate the coils from each other
(c) both (a) and (b)
(d) none of the above
Ans: a
33. Greater the secondary leakage flux
(a) less will be the secondary induced e.m.f.
(b) less will be the primary induced e.m.f.
(c) less will be the primary terminal voltage
(d) none of the above
Ans: a
34. The purpose of providing iron core in a step-up transformer is
(a) to provide coupling between primary and secondary
(b) to increase the magnitude of mutual flux
(c) to decrease the magnitude of mag-netizing current
(d) to provide all above features
Ans: c
35. The power transformer is a constant
(a) voltage device
(b) current device
(c) power device
(d) main flux device
Ans: d
36. Two transformers operating in parallel will share the load depending upon their
(a) leakage reactance
(b) per unit impedance
(c) efficiencies
(d) ratings
Ans: b
37. If R2 is the resistance of secondary winding of the transformer and K is the
transformation ratio then the equivalent secondary resistance referred to primary will be
(a) R2/VK
(b) R2IK2
(c) R22!K2
(d) R22/K
Ans: b
38. What will happen if the transformers working in parallel are not connected with
regard to polarity ?
(a) The power factor of the two trans-formers will be different from the power factor of
common load
(b) Incorrect polarity will result in dead short circuit
(c) The transformers will not share load in proportion to their kVA ratings
(d) none of the above
Ans: b
39. Ifthe percentage impedances of the two transformers working in parallel are different,
then
(a) transformers will be overheated
(b) power factors of both the trans-formers will be same
(c) parallel operation will be not possible
(d) parallel operation will still be possible, but the power factors at which the two
transformers operate will be different from the power factor of the common load
Ans: d
40. In a transformer the tappings are generally provided on
(a) primary side
(b) secondary side
(c) low voltage side
(d) high voltage side
Ans: c
41. The use of higher flux density in the transformer design
(a) reduces weight per kVA
(6) reduces iron losses
(c) reduces copper losses
(d) increases part load efficiency
Ans: a
42. The chemical used in breather for transformer should have the quality of
(a) ionizing air
(b) absorbing moisture
(c) cleansing the transformer oil
(d) cooling the transformer oil.
Ans: b
43. The chemical used in breather is
(a) asbestos fibre
(b) silica sand
(c) sodium chloride
(d) silica gel
Ans: d
44. An ideal transformer has infinite values of primary and secondary inductances. The
statement is
(a) true
(b) false
Ans: b
45. The transformer ratings are usually expressed in terms of
(a) volts
(b) amperes
(c) kW
(d) kVA
Ans: d
46. The noise resulting from vibrations of laminations set by magnetic forces, is termed as
(a) magnetostrication
(b) boo
(c) hum
(d) zoom
Ans: c
47. Hysteresis loss in a transformer varies as CBmax = maximum flux density)
(a) Bmax
(b) Bmax1-6
(C) Bmax1-83
(d) B max
Ans: b
48. Material used for construction of transformer core is usually
(a) wood
(b) copper
(c) aluminium
(d) silicon steel
Ans: d
49. The thickness of laminations used in a transformer is usually
(a) 0.4 mm to 0.5 mm
(b) 4 mm to 5 mm
(c) 14 mm to 15 mm
(d) 25 mm to 40 mm
Ans: a
50. The function of conservator in a transformer is
(a) to project against'internal fault
(b) to reduce copper as well as core losses
(c) to cool the transformer oil
(d) to take care of the expansion and contraction of transformer oil due to variation of
temperature of sur-roundings
Ans: d

Answer :

51. The highest voltage for transmitting electrical power in India is
(a) 33 kV.
(6) 66 kV
(c) 132 kV
(d) 400 kV
Ans: d
52. In a transformer the resistance between its primary and secondary is
(a) zero
(b) 1 ohm
(c) 1000 ohms
(d) infinite
Ans: d
53. A transformer oil must be free from
(a) sludge
(b) odour
(c) gases
(d) moisture
Ans: d
54. A Buchholz relay can be installed on
(a) auto-transformers
(b) air-cooled transformers
(c) welding transformers
(d) oil cooled transformers
Ans: d
55. Gas is usually not liberated due to dissociation of transformer oil unless the oil
temperature exceeds
(a) 50°C
(b) 80°C
(c) 100°C
(d) 150°C
Ans: d
56. The main reason for generation of harmonics in a transformer could be
(a) fluctuating load
(b) poor insulation
(c) mechanical vibrations
(d) saturation of core
Ans: d
57. Distribution transformers are generally designed for maximum efficiency around
(a) 90% load
(b) zero load
(c) 25% load
(d) 50% load
Ans: d
58. Which of the following property is not necessarily desirable in the material for
transformer core ?
(a) Mechanical strength
(6) Low hysteresis loss
(c) High thermal conductivity
(d) High permeability
Ans: c
59. Star/star transformers work satisfactorily when
(a) load is unbalanced only
(b) load is balanced only
(c) on balanced as well as unbalanced loads
(d) none of the above
Ans: b
60. Delta/star transformer works satisfactorily when
(a) load is balanced only
(b) load is unbalanced only
(c) on balanced as well as unbalanced loads
(d) none of the above
Ans: c
61. Buchholz's relay gives warning and protection against
(a) electrical fault inside the transformer itself
(b) electrical fault outside the transformer in outgoing feeder
(c) for both outside and inside faults
(d) none of the above
Ans: a
62. The magnetising current of a transformer is usually small because it has
(a) small air gap
(b) large leakage flux
(c) laminated silicon steel core
(d) fewer rotating parts
Ans: a
63. Which of the following does not change in an ordinary transformer ?
(a) Frequency
(b) Voltage
(c) Current
(d) Any of the above
Ans: a
64. Which of the following properties is not necessarily desirable for the material for
transformer core ?
(a) Low hysteresis loss
(b) High permeability
(c) High thermal conductivity
(d) Adequate mechanical strength
Ans: c
65. The leakage flux in a transformer depends upon
(a) load current
(b) load current and voltage
(c) load current, voltage and frequency
(d) load current, voltage, frequency and power factor
Ans: a
66. The path of the magnetic flux in transformer should have
(a) high reluctance
(b) low reactance
(c) high resistance
(d) low resistance
Ans: b
67. Noise level test in a transformer is a
(a) special test
(b) routine test
(c) type test
(d) none of the above
Ans: c
68. Which of the foJIowing is not a routine test on transformers ?
(a) Core insulation voltage test
(b) Impedance test
(c) Radio interference test
(d) Polarity test
Ans: c
69. A transformer can have zero voltage regulation at
(a) leading power factor
(b) lagging power factor
(c) unity power factor
(d) zero power factor
Ans: a
70. Helical coils can be used on
(a) low voltage side of high kVA trans¬formers
(b) high frequency transformers
(c) high voltage side of small capacity transformers
(d) high voltage side of high kVA rating transformers
Ans: a
71. Harmonics in transformer result in
(a) increased core losses
(b) increased I2R losses
(c) magnetic interference with communication circuits
(d) all of the above
Ans: d
72. The core used in high frequency transformer is usually
(a) copper core
(b) cost iron core
(c) air core
(d) mild steel core
Ans: c
73. The full-load copper loss of a trans¬former is 1600 W. At half-load, the copper loss will
be
(a) 6400 W
(b) 1600 W
(c) 800 W
(d) 400 W
Ans: d
1.74. The value of flux involved m the e.m.f. equation of a transformer is
(a) average value
(b) r.m.s. value
(c) maximum value
(d) instantaneous value
Ans: c
L.75. Silicon steel used in laminations mainly reduces
(a) hysteresis loss
(b) eddy current losses
(c) copper losses
(d) all of the above
Ans: a
76. Which winding of the transformer has less cross-sectional area ?
(a) Primary winding
(b) Secondary winding
(c) Low voltage winding
(d) High voltage winding
Ans: d
77. Power transformers are generally designed to have maximum efficiency around
(a) no-load
(b) half-load
(c) near full-load
(d) 10% overload
Ans: c
.78. Which of the following is the main advantage of an auto-transformer over a two
winding transformer ?
(a) Hysteresis losses are reduced
(b) Saving in winding material
(c) Copper losses are negligible
(d) Eddy losses are totally eliminated
Ans: b
79. During short circuit test iron losses are negligible because
(a) the current on secondary side is negligible
(b) the voltage on secondary side does not vary
(c) the voltage applied on primary side is low
(d) full-load current is not supplied to the transformer
Ans: c
80. Two transformers are connected in parallel. These transformers do not have equal
percentage impedance. This is likely to result in
(a) short-circuiting of the secondaries
(b) power factor of one of the trans¬formers is leading while that of the other lagging
(c) transformers having higher copper losses will have negligible core losses
(d) loading of the transformers not in proportion to their kVA ratings
Ans: d
81. The changes in volume of transformer cooling oil due to variation of atmospheric
temperature during day and
night is taken care of by which part of transformer
(a) Conservator
(b) Breather
(c) Bushings
(d) Buchholz relay
Ans: a
82. An ideal transformer is one which has
(a) no losses and magnetic leakage
(b) interleaved primary and secondary windings
(c) a common core for its primary and secondary windings
(d) core of stainless steel and winding of pure copper metal
(e) none of the above
Ans: a
83. When a given transformer is run at its rated voltage but reduced frequency, its
(a) flux density remains unaffected
(b) iron losses are reduced
(c) core flux density is reduced
(d) core flux density is increased
Ans: d
84. In an actual transformer the iron loss remains practically constant from noload to
fullload because
(a) value of transformation ratio remains constant
(b) permeability of transformer core remains constant
(c) core flux remains practically constant
(d) primary voltage remains constant
(c) secondary voltage remains constant
Ans: c
85. An ideal transformer will have maximum efficiency at a load such that
(a) copper loss = iron loss
(b) copper loss < iron loss
(c) copper loss > iron loss
(d) none of the above
Ans: a
86. If the supply frequency to the transformer is increased,"the iron loss will
(a) not change
(b) decrease
(c) increase
(d) any of the above
Ans: c
87. Negative voltage regulation is indicative that the load is
(a) capacitive only
(b) inductive only
(c) inductive or resistive
(d) none of the above
Ans: a
88. Iron loss of a transformer can be measured by
(a) low power factor wattmeter
(b) unity power factor wattmeter
(c) frequency meter
(d) any type of wattmeter
Ans: a
89. When secondary of a current transformer is open-circuited its iron core will be
(a) hot because of heavy iron losses taking place in it due to high flux density
(b) hot because primary will carry heavy current
(c) cool as there is no secondary current
(d) none of above will happen
Ans: a
90. The transformer laminations are insulated from each other by
(a) mica strip
(6) thin coat of varnish
(c) paper
(d) any of the above
Ans: b
91. Which type of winding is used in 3phase shell-type transformer ?
(a) Circular type
(b) Sandwich type
(c) Cylindrical type
(d) Rectangular type
Ans: b
92. During open circuit test of a transformer
(a) primary is supplied rated voltage
(b) primary is supplied full-load current
(c) primary is supplied current at reduced voltage
(d) primary is supplied rated kVA
Ans: a
93. Open circuit test on transformers is conducted to determine
(a) hysteresis losses
(b) copper losses
(c) core losses
(d) eddy current losses
Ans: c
94. Short circuit test on transformers is conducted to determine
(a) hysteresis losses
(b) copper losses
(c) core losses
(d) eddy current losses
Ans: b
95. For the parallel operation of single phase transformers it is necessary that they should
have
(a) same efficiency
(b) same polarity
(c) same kVA rating
(d) same number of turns on the secondary side.
Ans: b
96. The transformer oil should have _____ volatility and _____ viscosity.
(a) low,low
(b) high,high
(c) low,high
(d) high,low
Ans: a
97. The function of breather in a transformer is
(a) to provide oxygen inside the tank
(b) to cool the coils during reduced load
(c) to cool the transformer oil
(d) to arrest flow of moisture when outside air enters the transformer
Ans: d
98. The secondary winding of which of the following transformers is always kept closed ?
(a) Step-up transformer
(b) Step-down transformer
(c) Potential transformer
(d) Current transformer
Ans: d
99. The size of a transformer core will depend on
(a) frequency
(b) area of the core
(c) flux density of the core material
(d) (a) and (b) both
Ans: d
100. N atural air coo ling is generally restricted for transformers up to
(a) 1.5 MVA
(b) 5 MVA
(c) 15 MVA
(d) 50 MVA
Ans: a

Answer :

101. A shell-type transformer has
(a) high eddy current losses
(b) reduced magnetic leakage
(c) negligibly hysteresis losses
(d) none of the above
Ans: b
102. A transformer can have regulation closer to zero
(a) on full-load
(b) on overload
(c) on leading power factor
(d) on zero power factor
Ans: c
103. A transformer transforms
(a) voltage
(b) current
(c) current and voltage
(d) power
Ans: d
104. Which of the following is not the standard voltage for power supply in India ?
(a) llkV
(b) 33kV
(c) 66 kV
(d) 122 kV
Ans: d
105. Reduction in core losses and increase in permeability are obtained with transformer
employing
(a) core built-up of laminations of cold rolled grain oriented steel
(b) core built-up of laminations of hot rolled sheet
(c) either of the above
(d) none of the above
Ans: a
106. In a power or distribution transformer about 10 per cent end turns are heavily
insulated
(a) to withstand the high voltage drop due to line surge produced by the shunting
capacitance of the end turns
(b) to absorb the line surge voltage and save the winding of transformer from damage
(c) to reflect the line surge and save the winding of a transformer from damage
(d) none of the above
Ans: a
107. For given applied voltage, with the increase in frequency of the applied voltage
(a) eddy current loss will decrease
(b) eddy current loss will increase
(c) eddy current loss will remain unchanged
(d) none of the above
Ans: c
108. Losses which occur in rotating electric machines and do not occur in trans formers
are
(a) friction and windage losses
(b) magnetic losses
(c) hysteresis and eddy current losses
(d) copper losses
Ans: a
109. In a given transformer for a given applied voltage, losses which remain constant
irrespective of load changes are
(a) hysteresis and eddy current losses
(b) friction and windage losses
(c) copper losses
(d) none of the above
Ans: a
110. Which of the following statements regarding an idel single-phase transformer having
a turn ratio of 1 : 2 and
drawing a current of 10 A from 200 V A.C. supply is incorrect ?
(a) Its secondary current is 5 A
(b) Its secondary voltage is 400 V
(c) Its rating is 2 kVA
(d) Its secondary current is 20 A
(e) It is a step-up transformer
Ans: d
111 The secondary of a current transformer is always short-circuited under operating
conditions because it
(a) avoids core saturation and high voltage induction
(b) is safe to human beings
(c) protects the primary circuit
(d) none of the above
Ans: a
112. In a transformer the resistance between its primary and secondary should be
(a) zero
(b) 10 Q
(c) 1000 Q
(d) infinity
Ans: d
113. A good voltage regulation of a transformer means
(a) output voltage fluctuation from no load to full load is least
(b) output voltage fluctuation with power factor is least
(c) difference between primary and secondary voltage is least
(d) difference between primary and secondary voltage is maximum
Ans: a
114. For a transformer, operating at constant load current, maximum efficiency will occur
at
(a) 0.8 leading power factor
(b) 0.8 lagging power factor
(c) zero power factor
(d) unity power factor
Ans: d
115. Which of the following protection is normally not provided on small distribution
transformers ?
(a) Overfluxing protection
(b) Buchholz relay
(c) Overcurrent protection
(d) All of the above
Ans: b
116. Which of the following acts as a protection against high voltage surges due to
lightning and switching ?
(a) Horn gaps
(b) Thermal overload relays
(c) Breather
(d) Conservator
Ans: a
117. The efficiency of two identical transformers under load conditions can be
determined by
(a) short-circuit test
(b) back-to-back test
(c) open circuit test
(d) any of the above
Ans: b
118. Which of the following insulating materials can withstand the highest temperature
safely ?
(a) Cellulose
(b) Asbestos
(c) Mica
(d) Glass fibre
Ans: c
119. Which of the following parts of a transformer is visible from outside ?
(a) Bushings
(b) Core
(c) Primary winding
(d) Secondary winding
Ans: a
120. The noise produced by a transformer is termed as
(a) zoom
(b) hum
(c) ringing
(d) buzz
Ans: b
121. Which of the following loss in a transformer is zero even at full load ?
(a) Core loss
(b) Friction loss
(c) Eddy current loss
(d) Hysteresis loss
Ans: b
122. Which of the following is the most likely source of harmonics in a transformer ?
(a) poor insulation
(b) Overload
(c) loose connections
(d) Core saturation
Ans: d
123. If a transformer is continuously operated the maximum temperature rise will occur
in
(a) core
(b) windings
(c) tank
(d) any of the above
Ans: b
124. The hum in a transformer is mainly attributed to
(a) load changes
(b) oil in the transformer
(c) magnetostriction
(d) mechanical vibrations
Ans: c
125. The maximum load that a power transformer can carry is limited by its
(a) temperature rise
(b) dielectric strength of oil
(c) voltage ratio
(d) copper loss
Ans: c
126. The efficiency of a transformer, under heavy loads, is comparatively low because
(a) copper loss becomes high in proportion to the output
(b) iron loss is increased considerably
(c) voltage drop both in primary and secondary becomes large
(d) secondary output is much less as compared to primary input
Ans: a
127. An open-circuit test on a transformer is conducted primarily to measure
(a) insulation resistance
(b) copper loss
(c) core loss
(d) total loss
(e) efficiency
(f) none of the above
Ans: c
128. A no-load test is performed on a transformer to determine
(a) core loss
(b) copper loss
(c) efficiency
(d) magnetising current
(e) magnetising current and loss
Ans: e
129. The voltage transformation ratio of a transformer is equal to the ratio of
(a) primary turns to secondary turns
(b) secondary current to primary current
(c) secondary induced e.m.f. to primary induced e.m.f.
(d) secondary terminal voltage to primary applied voltage
Ans: c
130. Part of the transformer which is most subject to damage from overheating is
(a) iron core
(b) copper winding
(c) winding insulation
(d) frame or case
(e) transformer tank
Ans: c
131. If a transformer is switched on to a voltage more than the rated voltage
(a) its power factor will deteriorate
(b) its power factor will increase
(c) its power factor will remain unaffected
(d) its power factor will be zero
Ans: a
132. Auto-transformer makes effective saving on copper and copper losses, when its
transformation ratio is
(a) approximately equal to one
(b) less than one
(c) great than one
(d) none of the above
Ans: a
133. Minimum voltage regulation occurs when the power factor of the load is
(a) unity
(b) lagging
(c) leading
(d) zero
Ans: c
134. In a step-down transformer, there is a change of 15 A in the load current. This results
in change of supply current of
(a) less than 15 A
(b) more than 15 A
(c) 15 A
(d) none of the above
Ans: a
135. The efficiencies of transformers compared with that of electric motors of the same
power are
(a) about the same
(6) much smaller
(c) much higher
(d) somewhat smaller
(e) none of the above
Ans: c

Related questions

Description : TRANSMISSION AND DISTRIBUTION MCQ

Last Answer : 51. It is difficult to maintain oil filled cables. (a) Yes (b) No Ans: a 51. In capacitance grading a homogeneous dielectric is used. (a) Yes (b) No Ans: b 52. In congested areas where excavation is ... The metallic sheath may be made of lead or lead alloy or of aluminium. (a) Yes (b) No Ans: b

Description : SYNCHRONOUS MOTORS MCQ

Last Answer : 101. In a synchronous motor it the back e.m.f. generated in the armature at noload is approximately equal to the applied voltage, then (a) the motor is said to be fully loaded (b) the torque ... square of the applied voltage (c) inversely proportional to applied voltage (d) none of the above Ans: a

Description : SINGLE PHASE INDUCTION MOTORS MCQ

Last Answer : 101. After the starting winding of a single phase induction motor is disconnected from supply, it continues to run only on (a) running winding (b) rotor winding (c) field winding (d) compensating winding Ans: a ... motor is usually reduced by using (a) gearing (b) belts (c) brakes (d) chains Ans: a

Description : THREE PHASE INDUCTION MOTORS MCQ

Last Answer : 101. Insertion of resistance in the stator of an induction motor (a) increases the load torque (b) decreases the starting torque (c) increases the starting torque (d) none of the above Ans: b

Description : DC MOTOR MCQ

Last Answer : 101. Which of the following loss in a D.C. generator is dissipated in the form of heat? (a) Mechanical loss (b) Core loss (c) Copper loss (d) All of the above Ans: d 102. Which of the following ... (b) does not run as a generator (c) also runs as a motor comes to stop after sometime Ans: a

Description : DC GENERATORS MCQ

Last Answer : 101. Wave winding is composed of (a) any even number of conductors (b) any odd number of conductors (c) that even number which is exact multiple of poles + 2 (d) that even number ... increase the field resistance (c) increase the speed of primemover (d) check armature insulation resis¬tance Ans: a

Description : Power Maintenance MCQ

Last Answer : 1) Turbine pumps are used up to a suction head of ( b ) a. 1000 ft. c. 20 ft b. 100 ft d. 50 ft 2) The yard stick for provision of Electrical points in staff quarters can be changed by the Zonal railways ... is used for electrical fire ( b ) a. Water c. Foam b. Co2 & dry powder d. None of the above

Description : MCQ on Motor Control Center

Last Answer : 1. MCC stands for ______ a. Motor Control Center b. Motor Control Cost c. Machine Components Center d. None of the above Answer : a. Motor Control Center 2. MCC contains _____ a. Fuse b. MCB c. ... a) Start the motor b) Accelerate the motor c) Decelerate the motor d) Stop the motor Answer : a

Description : 74)Power transformers are generally designed to have maximum efficiency around A. No load B. Half load C. Near full load D. 10% overload

Last Answer : C. Near full load

Description : [23] Transformers are rated in KVA instead of KW because A. load power factor is often not known B. KVA is fixed whereas KW depends on load power factor C. Total transformer loss depends on volt ampere D. It has become customary

Last Answer : C. Total transformer loss depends on volt ampere

Description : What are the schedules of maintenance done on transformers?

Last Answer : Ans. Following are the schedules of maintenance on transformers. a. Daily maintenance. b. Monthly maintenance. c. Quarterly maintenance. d. Half yearly maintenance. e. Yearly maintenance. f. 5 Yearly maintenance.

Description : Why a transformer requires cooling. What are the methods of cooling transformers?

Last Answer : Ans. Transformers requires cooling as they get heated up due to various losses taking place in the transformer. (like iron of copper losses) Following are the methods of cooling of transformer. a. Natural ... . Forced oil air Natural Cooling (OFAN). d. Forced oil and forced Air cooling (OFAF).

Description : What are the loses in Transformers, Explain?

Last Answer : Ans. (1) Iron loses (2) Copper loses Iron Loss : Iron loss occurs in the transformers Iron core due to hysteresis and eddy currents taking place. They are almost fixed irrespective of ... losses in the primary and the secondary windings of the transformer which with the loading of transformer.

Description : Classify the transformers based on the construction, frequency and power.

Last Answer : Classification of Transformer Based On: i) Construction: Shell type, Core type, Berry type ii) Change in voltage level: Step-Up, Step-Down, iii) Number of phases: Single phase, Three phase iv) ... Control vi) Cooling: Self-cooled, Air-cooled, Forced-air cooled, Oil-cooled, Forced-oil cooled. 

Description : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Last Answer : Which of the following connection of transformers will give highest value of secondary voltage ? (A) Delta primary delta secondary (B) Delta primary star secondary (C) Star primary star secondary (D) Star primary delta secondary

Description : Two transformers A and B having equal outputs and voltage ratios but unequal percentage impedances of 4 and 2 are operating in parallel. The transformer A will be overloaded by 

Last Answer : Two transformers A and B having equal outputs and voltage ratios but unequal percentage impedances of 4 and 2 are operating in parallel. The transformer A will be overloaded by 33%

Description : Core type transformers are popular in___________.  (A) High voltage applications (B) Low voltage applications (C) All of the above (D) None of the above

Last Answer : Core type transformers are popular in High voltage applications

Description : In a transmission line if booster transformers are to be used, preferred location will be  (A) At the receiving end (B) At the sending end (C) At the intermediate point (D) Anywhere in the line 

Last Answer : In a transmission line if booster transformers are to be used, preferred location will be At the intermediate point

Description : The friction losses in Real Transformers are :  (A) 0% (B) 5% (C) 25% (D) 50%

Last Answer : A

Description : Two 3-phase transformers cannot be operated in parallel, if their :  (A) kVAs are different (B) phase sequences are different (C) % impedances are different (D) voltage ratios are different

Last Answer : Two 3-phase transformers cannot be operated in parallel, if their : phase sequences are different

Description : An additional condition for parallel operation of three-phase transformers over single-phase transformers is that

Last Answer : An additional condition for parallel operation of three-phase transformers over single-phase transformers is that the transformers should belong to the same vector group

Description : Which of the following is the advantage of using CRGO steel in transformers? A) High magnetic flux density B) Low permeability C) Both A and B D) None of these

Last Answer : It definitely High Magnetic Flux Density since a crgo steel has always a more around 3% of silicon proportion among the remaining ferrite which make cold rolled grain oriented steel having high flux magnetic ... for more about the crgo core you can learn here https://nicoreindia.com/crgo-core/

Last Answer : Instrument transformers are potential transformers, current transformers.

Last Answer : Natural oil cooling is used for transformers up to a rating of 3000 kVA.

Description : If the percentage impedances of the two transformers working in parallel are different, then?

Last Answer : If the percentage impedances of the two transformers working in parallel are different, then parallel operation will still be possible, but the power factors at which the two transformers operate will be different from the power factor of the common load.

Last Answer : Distribution transformers are generally designed for maximum efficiency around 50% load.

Last Answer : Power transformers are generally designed to have maximum efficiency around near full-load.

Description : Two transformers are connected in parallel. These transformers do not have equal percentage impedance. This is likely to result in?

Last Answer : Two transformers are connected in parallel. These transformers do not have equal percentage impedance. This is likely to result in loading of the transformers not in proportion to their kVA ratings.

Last Answer : Short circuit test on transformers is conducted to determine copper losses.

Last Answer : Necessary conditions required to be satisfied in order to ensure successful parallel operation of single phase transformers:  1. Only transformers having the same phase displacement between primary and secondary ... . 7. The phase sequence must be followed strictly on HV and LV side connection.

Last Answer : Natural air cooling is generally restricted for transformers up to 1.5 MVA .

Description : Losses which occur in rotating electric machines and do not occur in transformers are?

Last Answer : Friction losses windage losses 

Description : The efficiency of two identical transformers under load conditions can be determined by?

Last Answer : The efficiency of two identical transformers under load conditions can be determined by back-to-back test.

Description : The efficiencies of transformers compared with that of electric motors of the same power are?

Last Answer : Transformers have high efficiency than the same ratted motors

Last Answer : Current transformers (CT) : Current transformer (CT) actually step down the high current to low current for the operation of relays. Current transformer is use for measurement of ... use for relay. This is about potential transformer.

Description : Why do transformers make noise?

Last Answer : Transformers make noise based on it out put if an transformer outputs is 400v maximum than a 398v be apply to that transformer it also make a noise because of that 

Description : 78 Which type of winding is used in 3 phase shell type transformer? A. Circular type B. Sandwich type C. Cylindrical type D. Rectangular type

Last Answer : B. Sandwich type

Description : 73 The full load copper loss of a transformer is 1600W. At half-load the copper loss will be A. 6400W B. 1600W C. 800W D. 400W

Last Answer : D. 400W

Description : 5 The efficiency of a transformer is maximum when A. It runs at half full load B. it runs at full load C. its Cu loss equal iron loss D. it runs over load

Last Answer : C. Its cu loss equal iron loss

Description : State any two applications of single phase autotransformer.

Last Answer : Applications of single phase auto transformers: 1) Give small boost to distribution cable to correct the voltage drop. 2) As auto transformer starter for induction motors. 3) As furnace supply ... . 5) In control equipment for single phase locomotives. 6) As dimmer in lighting circuits.

Description : State any two conditions for parallel operation of 3-phase transformer.

Last Answer : Conditions for Parallel operation of 3 phase transformer 1) Voltage ratings of both the transformers must be identical. 2) Percentage or p.u. impedance should be equal in magnitude. 3) X/R ratio ... between primary & secondary voltages must be same. 6) Phase sequence on both sides must be same.

Description : Compare core type transformer and shell type transformer on the following parameters. (i) Types of winding used, (ii) Application

Last Answer : Ans:

Description : Define transformation ratio in terms of current and voltage.

Last Answer : (i) Transformation Ratio (K) is defined as the ratio of the primary current to the secondary current.  (ii) Transformation Ratio (K) is defined as the ratio of the secondary voltage to the primary voltage.

Description : Define: (i) Commercial efficiency of a transformer and  (ii) All day efficiency of a transformer.

Last Answer : (i) Commercial Efficiency : It is the ratio of output power in watt to the input power in watt. (ii) All day efficiency of a transformer: It is the ratio of output energy in kWh to the input energy in kWh in the 24 hours of the day

Description : A 50 KVA transformer has iron loss 2 kW on full load. Calculate its iron loss at 75% of full load.

Last Answer : Iron loss is dependent on voltage and independent of load. Hence iron loss at 75% of Load = Iron loss at full load = 2 kW

Description : State any four properties of Ideal transformer.

Last Answer : Properties of Ideal transformer: 1) No losses (iron and copper losses), hence no temperature rise. 2) No magnetic leakage i.e (Coefficient of coupling between primary and secondary windings is unity) 3) Zero winding ... drop i.e. E1 = V1, E2 = V2 5) Efficiency 100 %. 6) Regulation 0 %.

Description : Draw the connection diagram of long shunt differential D.C. compound generator.

Last Answer : Ans:

Description : Why circuit breaker connect b)w two transformer  (same rating

Last Answer : Because two transformers connection is in parallel to share the load if any transformer is receives the surge current because of the fault so to protect the other transformer from the fault. 

Last Answer : A common method of cooling a power transformer is oil cooling.