Multiple inlet system of air cooling of turbo-alternators can be used for machines of
rating upto
(a) 10 MW
(b) 30 MW
(c) 60 MW
(d) 150 MW

1 Answer

Answer :

(c) 60 MW

Related questions

Description : Which ofthe following methods is used for air cooling of turbo-alternators ? (a) One sided axial ventilation (b) Two sided axial ventilation (c) Multiple inlet system (d) All ofthe above

Last Answer : (d) All ofthe above

Description : With conventional hydrogen cooling it is possible to increase the rating of a single unit to (a) 50 MW (b) 100 MW (c) 200 MW (d) none ofthe above

Last Answer : (c) 200 MW

Description : The cylindrical windings using circular conductors are used for current rating of (a) upto 20 A (b) upto 40 A (c) upto 60 A (d) upto 80 A

Last Answer : (d) upto 80 A

Description : With direct water cooling it is possible to have ratings of about (a) 200 MW (b) 300 MW (c) 400 MW (d) 600 MW

Last Answer : (d) 600 MW

Description : Transformers with a capacity of upto _____ have a cooling radiator system with natural cooling (a) 2 MVA (b) 5 MVA (c) 7.5 MVA (d) 10 MVA

Last Answer : (d) 10 MVA

Description : The forced oil and air circulation method is usual one for transformers of capacities (a) upto 5 MVA (b) upto 10 MVA (c) upto 20 MVA (d) 30 MVA upwards

Last Answer : (d) 30 MVA upwards

Description : Electrical machines having power outputs ranging from a few kW upto approximately 250 kW may be classified as (a) small size machines (b) medium size machines (c) large size machines (d) any ofthe above

Last Answer : (b) medium size machines

Description : Electrical machines having a power output upto about 750 W may be called_______machines. (a) small size (b) medium size (c) large size (d) any of the above

Last Answer : (a) small size

Description : Machines cooled by direct cooling method may be called (a) "supercharged" (b) "inner cooled" (c) "conductor cooled" (d) any of the above

Last Answer : (d) any of the above

Description : In D.C. machines the number of slots per pole usually lies (a) between 2 to 4 (b) between 6 to 8 (c) between 9 to 16 (d) between 20 to 30

Last Answer : (c) between 9 to 16

Description : D.C. machines designed with a large value of air gap length have (a) worst, ventilation (b) poor ventilation (c) better ventilation (d) none of the above

Last Answer : (c) better ventilation

Description : Multi-layer helical windings are commonly used in the transformers as high voltage windings (a) upto 20 kV (b) upto 50 kV (c) upto 80 kV (d) for 110 kV and above

Last Answer : (d) for 110 kV and above

Description : In D.C. machines the usual limit of slot pitch is (a) between 5 to 10 mm (b) between 10 to 15 mm (c) between 15 to 20 mm (d) between 25 to 35 mm

Last Answer : (d) between 25 to 35 mm

Description : In D.C. machines the width of the duct is usually (a) 4 mm (b) 6 mm (c) 8 mm (d) 10 mm

Last Answer : (d) 10 mm

Description : Power transformers have rating (a) equal to 50 kVA (6) equal to 100 kVA (c) above 200 kVA (d) none of the above

Last Answer : (c) above 200 kVA

Description : By which of the following methods motor rating for variable load drives can be determined ? (a) Method of average losses (b) Equivalent current method (c) Equivalent torque method (d) Equivalent power method (e) All of the above.

Last Answer : (e) All of the above.

Description : In D.C. machines, the ____ in field mmf results in increase in size and cost of machines. (a) increase (b) decrease (c) either of the above (d) none of the above

Last Answer : (a) increase

Description : In D.C. machines, ir order to prevent excessive distortion of field form by the armature reaction, the field mmf must be made (a) equal to that of armature mmf (b) less in comparison with the arma¬ture mmf (c) large in comparison with the arma-ture mmf (d) none of the above

Last Answer : (c) large in comparison with the arma-ture mmf

Description : Dummy coil should not be used in (a) small machines (b) large machines (c) either (a) or (b) (d) none of the above

Last Answer : (b) large machines

Description : is universally used for windings of electrical machines because it is easily workable without any possibility of fracture. (a) Silver (b) Steel (c) Aluminium (d) Copper

Last Answer : (d) Copper

Description : The action of electromagnetic machines can be related to which ofthe following basic principles ? (a) Induction (b) Interaction (c) Alignment (d) All of the above

Last Answer : (d) All of the above

Description : Commercial available medium size machines have a speed range of ______ . (a) 200 to 400 r.p.m. (b) 600 to 1000 r.p.m. (c) 1000 to 1500 r.p.m. (d) 2000 to 2500 r.p.m.

Last Answer : (d) 2000 to 2500 r.p.m.

Description : In ______ machines, the size of the shaft is decided by the critical speed which depends on the deflection of the shaft. (a) small (b) medium (c) large (d) any of the above.

Last Answer : (c) large

Description : The design of mechanical parts is particularly important in case of _____ speed machines. (a) low (b) medium (c) high (d) any of the above

Last Answer : (c) high

Description : A current density of _____ is ilsed for large power transformers with forced circulation of oil or with water cooling coils (a) 1.5 to 2.5 A/mm2 (b) 3.5 to 4.5 A/mm2 (c) 4.0 to 5.0 A/mm2 (d) 5.4 to 6.2 A/mm2

Last Answer : (d) 5.4 to 6.2 A/mm2

Description : In self cooled motors the cooling time constant is about ______ than the heating time constant because cooling conditions are worse at standstill. (a) 2 to 3 times greater (b) 3 to 4 times greater (c) 4 to 5 times greater (d) none of the above

Last Answer : (a) 2 to 3 times greater

Description : The time taken by the machine to attain 0.632 of its final steady temperature rise is called (a) heating time constant (b) cooling time constant (c) either (a) or (b) (d) none of the above

Last Answer : (a) heating time constant

Description : Direct water cooling of rotor winding presents (a) no mechanical difficulties (b) lesser mechanical difficulties (c) greater mechanical difficulties (d) none of the above

Last Answer : (c) greater mechanical difficulties

Description : cooling is the process of dissipating the armature and field winding losses to a cooling medium circulating within the winding insulation wall (a) Direct (b) Indirect (c) Conventional (d) Any ofthe above

Last Answer : (a) Direct

Description : Which ofthe following is an advantage of hydrogen cooling ? (a) Increase in efficiency (b) Increase in ratings (c) Increase in life (d) Smaller size of coolers (e) All ofthe above

Last Answer : (e) All ofthe above

Description : In a D.C. machine, the value of peripheral speed should not, normally, exceed (a) 10 m/s (b) 20 m/s (c) 30 m/s (d) 40 m/s

Last Answer : (c) 30 m/s

Description : In transformers using hot rolled steel, the cross-section of the yoke is made about _____ greater than that of the core (a) 5 percent (b) 10 percent (c) 15 percent (d) 30 percent (e) none of the above

Last Answer : (c) 15 percent

Description : The heat dissipating capability of transformers of ratings higher than 30 kVA in increased by providing which of the following ? (a) Corrugations (b) Fins (c) Tubes (d) Radiator tanks (e) All of the above

Last Answer : (e) All of the above

Description : For a 210 MW, turbo-alternator in a thermal power plant, the possible specifications of rotor diameter, stator core length, and number of poles, respectively, are (A) 4.4 m, 1.2 m, 12 (B) 1.2 m, 4.4 m, 2 (C) 4.4 m, 1.2 m, 24 (D) 1.2 m, 4.4 m, 8

Last Answer : For a 210 MW, turbo-alternator in a thermal power plant, the possible specifications of rotor diameter, stator core length, and number of poles, respectively, are 1.2 m, 4.4 m, 2

Description : Which of the following methods may be adopted to reduce the effects of armature reaction ? (a) Increase in length of air gap at pole tips (b) Increasing reluctance of pole tips (c) Compensating windings (d) Interpoles (e) All of the above

Last Answer : (e) All of the above

Description : The operation of a D.C. machine with large air gap lengths is comparatively (a) quiet (b) noisy (c) either of the above (d) none of the above

Last Answer : (a) quiet

Description : For large power transformers, self oil cooled type or air blast type which of the following values of current density may be used ? (a) 1.0 to 1.2 A/mm2 (b) 1.5 to 2.0 A/mm2 (c) 2.2 to 3.2 A/mm2 (d) 3.2 to 4.2 A/mm2

Last Answer : (c) 2.2 to 3.2 A/mm2

Description : The slot leakage can be calculated by making which of the following assumptions ? (a) The current in the slot conductors is uniformly distributed over their cross-section (b) The leakage path is straight ... is only considered. The reluctance of iron paths is assumed as zero (d) All of the above

Last Answer : (d) All of the above

Description : The noise produced by a ______ cooled machine is less as the rotor moves in a medium of smaller density. (a) air (b) hydrogen (c) either (a) or (b) (d) none of the above

Last Answer : (b) hydrogen

Description : The thermal conductivity of hydrogen is ______ times that of air (a) 2 (b) 3 (c) 5 (d) 7

Last Answer : (d) 7

Description : Hydrogen has a heat transfer co-efficient _____ times that of air (a) 1.5 (b) 2.5 (c) 3.5 (d) 4.5

Last Answer : (a) 1.5

Description : The density of hydrogen is _____ times the density of air. (a) 0.07 (b) 1.5 (c) 2.5 (d) 3.5

Last Answer : (a) 0.07

Description : The mcrease in heat dissipation by air blasts is due to increase in (a) conduction (b) convection (e) radiation (d) any ofthe above

Last Answer : (b) convection

Description : The length cf air gap to be provided in ______ is primarily determined by power factor consideration. (a) d.c. series motor . (b) d.c. shunt motor (c) induction motor (d) synchronous motor

Last Answer : (c) induction motor

Description : In induction motors, the length of air gap in kept as small as mechanically possible is order to have (a) low power factor (b) high power factor (c) high over load capacity (d) any of the above

Last Answer : (b) high power factor

Description : What Is Meant By Turbo Alternators?

Last Answer : Turbo alternators are high speed alternators. Because of high speed of rotation, the rotor diameter is reduced and the axial length is increased. Two or four poles are generally used and steam turbines are used as prime movers.

Description : Which rotor is use for high speed in turbo alternators?

Last Answer : Non-salient pole rotor is used for high speed in turbo alternators.

Description : The resistivity of water should not be less than (a) 10 Q m (b) 100 Q m (c) 1000 Q m (d) 2000 Q m

Last Answer : (d) 2000 Q m

Description : In direct cooled system using hydrogen both stator and rotor conductors are made (a) solid (b) hollow (c) perforated (d) any ofthe above

Last Answer : (b) hollow

Description : In a D.C. machine the current per brush arm should not be more than (a) 100 A (6) 200 A (e) 300 A (d) 400 A