What is the power factor in pure resistive , capacitive , inductive load ?

1 Answer

Answer :

Answer : Power factor cosΦ = 1 in pure resistive load, cosΦ = 0 in capacitive load , cosΦ = 0 in inductive load .

Related questions

Description : Voltage will always lead current in a/an ______________. A. capacitive circuit B. inductive circuit C. magnetic circuit D. resistive circuit

Last Answer : Answer: B

Description : What is the reactance property at the input of a shorted quarter wavelength line? A. A parallel LC circuit B. A pure inductive reactance C. A series LC circuit D. A pure capacitive reactance

Last Answer : A. A parallel LC circuit

Description : Transmission lines when connected to antenna have A. capacitive load B. resistive load whose resistance is less than characteristics impedance C. resistive load at the resonant frequency D. resistive load whose resistance is greater than the characteristic impedance of the line

Last Answer : C. resistive load at the resonant frequency

Description : Capacitors can be used in electric distribution systems to improve power factor. This is accomplished by seesawing energy between the capacitor and the _____________. A. generator B. inductive loads C. resistive loads D. all of the above

Last Answer : Answer: B

Description : Which of the following statements concerning AC circuits is correct? A. The power factor of a resistive circuit is always zero. B. True power in an inductive circuit always equals apparent power. ... . D. Total opposition to the flow of alternating current depends upon the amount of reactive power.

Last Answer : Answer: C

Description : For an Resistive Load and Inductive load considered for switching operation of circuit breaker, Switching of which load is difficult and Why?

Last Answer : In case of switching resistive load, current and voltage will be in phase i.e,when during current zero voltage also will be zero in case of resistive load. Hence the voltage at the ... maximum. This results in re-striking of arc once again. Therefore switching inductive load will be difficult

Description : The ratio of the effective value of the counter EMF in volts, to the effective value of the current in amperes is called _____________. A. impedance factor B. capacitive reactance C. inductive reactance D. root mean square

Last Answer : Answer: C

Description : What is the expression of capacitive reactance ?

Last Answer : Capacitive reactance = XC

Description : When using an ohmmeter to test a semiconductor diode, you find a low resistance in both the forward and reverse bias directions. This indicates that the diode has a/an ____________. A. open B. short C. good resistive quality D. good capacitive quality

Last Answer : Answer: B

Description : Write the formula for inductive reaction ?

Last Answer : Formula for inductive reactance: XL = 2τƒL . It depends on the frequency and inductance of the coil. Since the inductance of a coil is constant, its inductive reactance changes at a rate proportional to the change in frequency.

Last Answer : In the case of power measurement by two wattmeter method in a balanced 3Φ system with a pure inductive load both the Wattmeter will indicate the same but of opposite sign.

Description : The electrical diagram shown in the illustration is used to depict a/an ____________. EL-0015 A. resistance circuit B. inductive circuit C. stepdown circuit D. capacitive circuit

Last Answer : Answer: D

Description : An AC circuit has a capacitive reactance of 30 ohms in addition to an inductive reactance of 40 ohms connected in series. What is the reactance of the circuit? A. 8.37 ohms B. 10.00 ohms C. 50.00 ohms D. 70.00 ohms

Last Answer : Answer: B

Description : The combined effect of inductive reactance, capacitive reactance, and resistance in an AC series circuit is known as _____________. A. reactance B. total reactance C. impedance D. resonance

Last Answer : Answer: C

Description : Noise that occurs via capacitive or inductive coupling in a cable. A. Crosstalk B. Quantizing noise C. Reference noise D. Tone interference

Last Answer : A. Crosstalk

Description : In series RLC circuit at resonant a) Voltage is in phase with current b) Current is maximum c) Inductive reactance = Capacitive reactance d) All of the above

Last Answer : Ans: All of the above

Description : Series capacitors are used to (a) compensate for line inductive reactance (b) compensate for line capacitive reactance (c) improve line voltage (d) none of the above

Last Answer : (a) compensate for line inductive reactance

Description : Bridge used to measure both inductive and capacitive impedances at higher frequencies

Last Answer : radio-frequency bridge

Description : Draw and explain the working of inductive and capacitive sensors.

Last Answer : Ans: Inductive Sensor: Diagram: Operation: An inductive sensor consist of a coil wound around a ferrous metallic core ,detector circuit and solid state output . With supply voltage ,oscillator operates to ... output device being ON or OFF. Capacitive Sensor: Diagram: Working  

Description : What is load factor ?

Last Answer : The ratio of average load to maximum load of a power plant or customer is called load factor.

Description : A single-phase voltage source square -wave inverter feeds pure inductive load. The waveform of the load current will be

Last Answer : A single-phase voltage source square -wave inverter feeds pure inductive load. The waveform of the load current will be triangular

Description : In a pure resistive circuit, the average power Pavg is ______ the peak power Pmax. (1) Double (2) One-half of (3) One-fourth (4) Equal to

Last Answer : In a pure resistive circuit, the average power Pavg is One-half of the peak power Pmax.

Description : A single phase 60 Hz generator supplies an inductive load of 4500kW at a power factor of 0.80 lagging by means of a 20 km long overhead transmission line. The line resistance and inductance are 0.0195 ohm and 0.60 mH ... voltage regulation of the line.  (A) 12.59% (B) 16.34% (C) 32.68% (D) 41.15% 

Last Answer : Answer is C

Description : In a pure resistive circuit?

Last Answer : In a pure resistive circuit current is in phase with the voltage.

Description : What is the best economic power factor ?

Last Answer : This means that raising the power factor results in maximum annual savings , in which case the value of the power factor is called the best saving power factor.

Description : What happens if the value of power factor is low ?

Last Answer : ( a) Current flows more , ( b) Copper loss increases , ( c) Heat increases , ( d) Output decreases , ( e) Voltage drop increases , ( f) Different electrical machinery heats up quickly. , ( G) The life span of various electrical machinery and appliances is reduced.

Description : What is the Leading Power Factor ?

Last Answer : When the capacitive load of an AC circuit exceeds the inductive load , the pf of the circuit is called the leading pf . Thank you!

Description : What is Lagging Power Factor ?

Last Answer : When the inductive load of an AC circuit exceeds the capacitive load , the pf of the circuit is called lagging pf .

Description : What is Unity Power Factor ?

Last Answer : There is no angular gap between current and voltage in pure resistance. That is, the phase angle of current and voltage is φ = 0, the power factor of that circuit is one or unit. This is called Unity Power Factor.

Description : What is the leading power factor ?

Last Answer : When the amount of capacitive load is more than the inductive load in a circuit then the power factor of that circuit is called leading power factor.

Description : What is lagging power factor ?

Last Answer : When the amount of inductive load is greater than the capacitive load in a circuit then the power factor of that circuit is called lagging power factor.

Description : How many types of power factor ?

Last Answer : Three types , namely , 1) lagging power factor , 2) leading power factor , 3) unity power

Description : What is the effect of resistance and reactance on power factor ?

Last Answer : Power factor depends on resistance and reactance. As the resistance of the circuit increases, the phase angle between the current and the voltage decreases, resulting in an increase in the power factor ... current and the voltage increases, resulting in a decrease in the power factor of the circuit.

Description : What is lagging power factor ?

Last Answer : The cosine value of the phase angle between current and voltage in an inductive circuit is called lagging power factor.

Description : What is Power Factor ?

Last Answer : The phase factor or the cosine value of the angular interval between the voltage and current of an AC circuit is called the power factor.

Description : When is the power factor lagging , leading , unity ?

Last Answer : Power factor lagging in inductive load. Power factor leading in capacitive load is power factor unity in resistive load.

Description : What is a Power Factor Meter ?

Last Answer : The cosine angle between voltage and current is called power factor

Description : What is the value of power factor ?

Last Answer : The value of power factor is Cos Theta

Description : What is the power factor expressed by ?

Last Answer : The power factor is expressed by cos theta.

Description : What is Leading Power Factor ?

Last Answer : If the current in the AC circuit is ahead of the voltage, it is called leading power factor.

Last Answer : The average power in a pure inductive circuit is 0.

Description : Pure inductive circuit takes power from the A.C. line when?

Last Answer : It takes power when voltage decreases and current increases.

Description : In a pure capacitive circuit if the supply frequency is reduced to 1/2, the current will?

Last Answer : In a pure capacitive circuit if the supply frequency is reduced to 1/2, the current will be reduced by half.

Description : The presence of standing waves on a transmission line is the result of A. a high level of attenuation on the line. B. terminating the line by a resistive load equal in value to the surge impedance ... input power to below its critical level. D. an impedance mismatch between the load and the line.

Last Answer : D. an impedance mismatch between the load and the line.

Description : What is the power factor of purely resistive circuit.

Last Answer : Unity that is 1

Description : In order to get maximum power transfer from a capacitive source, the load must? A.have a capacitive reactance equal to circuit resistance B.have an impedance that is the complex conjugate of the source impedance C.be as capacitive as it is inductive D.none of the above

Last Answer : In order to get maximum power transfer from a capacitive source, the load must? A.have a capacitive reactance equal to circuit resistance B.have an impedance that is the complex conjugate of the source impedance C.be as capacitive as it is inductive D.none of the above

Description : A series combination of resistance 100 ohm and capacitance 50µf is connected in series to a 230 V, 50HZ supply. Calculate (i) Capacitive reactance (ii) Current (iii) Power factor (iv) Power consumed 

Last Answer : For RC series circuit

Description : What is peak load ?

Last Answer : The maximum load of a plant or customer is called peak load.

Description : What is the no-load current of transformer ?