A 220/440 V, 50 Hz, 5 KVA, single phase transformer operates on 220V, 40Hz
supply with secondary winding open circuited. Then
(A) Both eddy current and hysteresis losses decreases.
(B) Both eddy current and hysteresis losses increases.
(C) Eddy current loss remains the same but hysteresis loss increases.
(D) Eddy current loss increases but hysteresis loss remains the same.

1 Answer

Answer :

(A) Both eddy current and hysteresis losses decreases.

Related questions

Description : If a 220/440 V, 50 Hz, 5 KVA, single-phase transformer operates on 220V, 40Hz supply with secondary winding open circuited: (A) both the eddy current and the hysteresis losses will decrease ... losses will increase (D) eddy current losses will increase but the hysteresis losses will remain the same

Last Answer : If a 220/440 V, 50 Hz, 5 KVA, single-phase transformer operates on 220V, 40Hz supply with secondary winding open circuited: both the eddy current and the hysteresis losses will decrease

Description : The hysteresis and eddy current losses of a single phase transformer working on 200 V, 50 Hz supply are Ph and Pe respectively. The percentage decrease in these when operated on a 160 V, 40 Hz supply are   (a) 32, 36 (b) 20, 36 (c) 25, 50 (d) 40, 80 

Last Answer : The hysteresis and eddy current losses of a single phase transformer working on 200 V, 50 Hz supply are Ph and Pe respectively. The percentage decrease in these when operated on a 160 V, 40 Hz supply are 20, 36

Description : The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be (A) 3.6 V. (B) 2.5 V. (C) 3.0 V. (D) 6.0 V.

Last Answer : (C) 3.0 V.

Description : The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be (A) 3.6 V. (B) 2.5 V. (C) 3.0 V. (D) 6.0 V.

Last Answer : The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be 3.0 V.

Description : The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be; (A) 3.6 (B) 2.5 V (C) 3.0 V (D) 6.0 V

Last Answer : The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be: 3.0 V

Description : Which of the following losses is/are present in every direct current generator armature? A. Winding copper loss B. Core eddy current loss C. Magnetic hysteresis loss D. All of the above.

Last Answer : Answer: D

Description : A transformer at 25 Hz develops 20 W hysteresis loss and 50 W eddy current loss. If the applied voltage and frequency are doubled, the new core losses are (A) 140 W (B) 180 W (C) 240 W (D) 480 W

Last Answer : A transformer at 25 Hz develops 20 W hysteresis loss and 50 W eddy current loss. If the applied voltage and frequency are doubled, the new core losses are 240 W

Description : 7 The main advantage of auto transformer over a two winding transformer is A. Hysteresis losses are reduced B. Saving in winding material C. Copper losses are negligible D. Eddy losses are totally eliminated

Last Answer : A) hysteresis losses is reduced

Description : 43 The purpose of providing an iron core in a transformer is to A.Provide support to windings B. Reduce hysteresis loss C. decrease the reluctance of the magnetic path D. reduce eddy current losses

Last Answer : C. Decrease the reluctance of the magnetic path

Description : A single-phase, 50 kVA, 250 V/500 V two winding transformer has an efficiency of 95% at full load, unity power factor. If it is re-configured as a 500 V/750 V auto-transformer, its efficiency at its new rated load at unity power factor will be  (A) 95.752% (B) 97.851% (C) 98.276% (D) 99.241%

Last Answer : A

Description : Turn ratio of a transformer is 5. If 220 V AC is applied to its primary coil, voltage in the secondary coil will be: a. 44V b. 4.4 V c. 220V d. 1100V

Last Answer : c. 220V

Description : What is the maximum current allowed to be drawn from the secondary of a 2 KVA step-down transformer with a turns ratio of four to one if connected across a 440 volt line? A. 1.1 amps B. 4.5 amps C. 18.1 amps D. 22.7 amps

Last Answer : Answer: C

Description : The armature of a dc machine is laminated to reduce: (A) Eddy current loss (B) Hysteresis loss (C) copper losses (D) friction and windage losses

Last Answer : Ans: A Thinner the laminations, greater is the resistance offered to the induced e.m.f., smaller the current and hence lesser the I2R loss in the core.

Description : A transformer steps down 220V to 40 volts. If the secondary turns are 40 then primary turns will be: a. 20 b. 40 c. 120 d. 220

Last Answer : d. 220V

Description : 42 The efficiency of a transformer will be maximum when A. copper losses = hysteresis losses B. Hysteresis losses = eddy current losses C. Eddy current losses = copper losses D. Copper losses = iron losses

Last Answer : D. Copper losses = iron losses

Description : The eddy current loss in an AC motor is 100 watts at 50 Hz. Its losses at 100 Hz will be: (A) 25 watts (B) 59 watts (C) 100 watts (D) 400 watts

Last Answer : The eddy current loss in an AC motor is 100 watts at 50 Hz. Its losses at 100 Hz will be: 400 watts

Description : A solar cell of 350 V is feeding power to an ac supply of 440 V, 50 Hz through a 3-phase fully controlled bridge converter. A large inductance is connected in the dc circuit to maintain the dc current at 20 A ... thyristor will be reverse biased for a period of  (A) 125o (B) 120o (C) 60o (D) 55o

Last Answer : A solar cell of 350 V is feeding power to an ac supply of 440 V, 50 Hz through a 3-phase fully controlled bridge converter. A large inductance is connected in the dc circuit to maintain the ... the solar cell resistance is 0.5 Ohm ,then each thyristor will be reverse biased for a period of 125o

Description : The armature cores of the D.C. motors are constructed with laminations to ___________. A. eliminate hysteresis B. minimize brush sparking C. reduce eddy current losses D. compensate for armature reaction

Last Answer : Answer: C

Description : The armature cores of the D.C. motors are constructed with laminations to ___________. A. eliminate hysteresis B. minimize brush sparking C. reduce eddy current losses D. compensate for armature reaction

Last Answer : Answer: C

Description : Armature cores in a DC generator are made of laminated steel sheets to _____________. A. fit the curvature of the frame B. increase the hysteresis effect C. reduce eddy current losses D. allow for easy assembly

Last Answer : Answer: C

Description : 70] Silicon steel used in laminations mainly reduces A. Hysteresis loss B. Eddy current losses C. Copper loss D. All of the above

Last Answer : A. Hysteresis loss

Description : A single phase transformer is designed to operate from 50 Hz, 1100 V supply and to have an output voltage of 240 V at no load. The core has mean area of 30 cm2 and the flux density has not to exceed 1.3T. The number of secondary turns will be (a) 1270 (b) 1017 (c) 768 (d) 277  

Last Answer : E2=e2=4.44*flux*N2*f=240 V Flux=Flux density* Area Area=30 cm2  =30*10-4 m2 Flux= 1.3*30*10-4  Wb=39*10-4 Wb E=240= 4.44*39*10-4 *N2*50      N2=277.

Description : What is the maximum allowable primary current of a 2 KVA step-down transformer with a four to one turns ratio if connected across a 440 volt line? A. 1.1 amps B. 4.5 amps C. 18.1 amps D. 27.7 amps

Last Answer : Answer: B

Description : The low voltage winding of a 400/230 V, 1-phase, 50 Hz transformer is to be connected to a 25 Hz, the supply voltage should be

Last Answer : The low voltage winding of a 400/230 V, 1-phase, 50 Hz transformer is to be connected to a 25 Hz, the supply voltage should be 115 V.

Description : A 12 -pole, 440 V, 50 Hz, 3 -phase synchronous motor takes a line current of 100 A at 0.8 pf leading. Neglecting losses, the torque developed will be

Last Answer : A 12 -pole, 440 V, 50 Hz, 3 -phase synchronous motor takes a line current of 100 A at 0.8 pf leading. Neglecting losses, the torque developed will be 1165 Nm

Description : Booster transformer should never: a) Have fuse in the HV winding b) Be left open circuited c) Be left closed circuited d) None of the above

Last Answer : Ans: B

Description : 9 Which loss is not common between a transformer and rotating machines? A. Eddy current loss B. Copper loss C. Windage loss D. Hysteresis loss

Last Answer : A. Eddy current loss

Description : 24 Transformer cores are laminated in order to A. simplify its construction B. minimise eddy current loss C. reduce cost D. reduce hysteresis loss

Last Answer : B. Minimise eddy current loss

Description : 17. Which type of loss is not common to transformer and rotating machines? A. Eddy current loss B. Copper loss C. Hysteresis loss D. Windage loss

Last Answer : D. Windage loss

Description : The eddy current loss in an a-c electric motor is 100 watts at 50 Hz. Its loss at 100 Hz will be (A) 25 watts (B) 59 watts (C) 100 watts (D) 400 watts

Last Answer : (D) 400 watts

Description : A process electric heater is taking an hour to reach the desired temperature while operating at 440 V. It will take ------- hours to reach the same temperature if the supply voltage is reduced to 220 V. a) 2 b) 3 c) 4 d) 5

Last Answer : c) 4

Description : A single phase transformer rated at 3000 kVA, 69 kV 4.16 kV, 60 Hz has a total internal impedance Zp of 127 ohm, referred to the primary side. Calculate the primary current if the secondary is accidentally short circuited.  (A) 43.5 A (B) 543 A (C) 9006 A (D) 721 A 

Last Answer : 543A

Last Answer : No eddy current and hysteresis losses occur in Electrostatic instruments.

Description : As an armature revolves within a magnetic field, friction is developed between the rotated magnetized particles as they pass through each magnetization cycle. This results in ____________. A. copper loss B. eddy-current loss C. hysteresis loss D. armature reaction

Last Answer : Answer: C

Description : A dc cumulatively compounded motor delivers rated load torque at rated speed. If series field is short circuited, then the armature current and speed will a) Both increases b) Both decreases c) Increases and decreases d) Decreases and increases

Last Answer : Ans: Both increases

Description : A three-phase, 440 V, 50 Hz ac mains fed thyristor bridge is feeding a 440 V dc, 15 kW, 1500 rpm separately excited dc motor with a ripple free continuous current in the dc link under all operating conditions, Neglecting the ... at half the rated speed is  (A) 0.354 (B) 0.372 (C) 0.90 (D) 0.955

Last Answer : A three-phase, 440 V, 50 Hz ac mains fed thyristor bridge is feeding a 440 V dc, 15 kW, 1500 rpm separately excited dc motor with a ripple free continuous current in the dc link under all operating conditions, Neglecting the losses, the power factor of the ac mains at half the rated speed is 0.354

Description : Although saturable reactors are extremely useful in some applications, their gain is low because of ____________. A. core hysteresis losses B. inductive reactance in the control winding C. IR drop throughout the load winding D. all of the above

Last Answer : Answer: A

Description : 69 In case there are burrs on the edges of the laminations of the transformer, it is likely to result in A. Vibrations B. Noise C. Higher eddy currents loss D. Higher hysteresis loss

Last Answer : C. Higher eddy currents loss

Description : The rating of the Transformer __ when the supply frequency is increased: a) Remains unchanged b) Increases c) Decreases d) None of the above

Last Answer : Ans: B

Description : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Last Answer : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Description : A CT has 2 – secondary windings. If we use only one secondary winding can we keep the unused secondary winding short circuited?

Last Answer : No. If it is short-circuited then the ratio will not get correctly. The turns of primary winding will be shared between 2 secondary windings. So the unused secondary winding should kept open. 

Description : For V/F control, when frequency is increased in transformer a) Core loss component current increases, Magnetizing component current decreases b) Core loss component current increases, ... component current decreases d) Core loss component current decreases, Magnetizing component current increases

Last Answer : Ans: Core loss component current decreases, Magnetizing component current decreases

Description : A 400V/100 V, 10 KVA two-winding transformer is reconnected as an auto-transformer across a suitable voltage source. The maximum rating of such an arrangement could be  A) 50 KVA B) 15 KVA C) 12.5 KVA D) 8.75 KVA

Last Answer : A 400V/100 V, 10 KVA two-winding transformer is reconnected as an auto-transformer across a suitable voltage source. The maximum rating of such an arrangement could be 50 KVA

Description : The magnetizing reactance of a 4 kV/ 400 V, 50 Hz single-phase transformer on low voltage side is 35 Ω. The magnetizing reactance on the high voltage side is (A) 0.35 Ω (B) 3.5 Ω (C) 350 Ω (D) 3500 Ω

Last Answer : 3500

Description : A single-phase, 230 V, 50 Hz ac mains fed step down transformer (4:1) is supplying power to a half-wave uncontrolled ac-dc converter used for charging a battery (12 V dc) with the series current limiting resistor being 19.04 Ohm. The charging current is  (A) 2.43 A (B) 1.65 A (C) 1.22 A (D) 1.0 A

Last Answer : A single-phase, 230 V, 50 Hz ac mains fed step down transformer (4:1) is supplying power to a half-wave uncontrolled ac-dc converter used for charging a battery (12 V dc) with the series current limiting resistor being 19.04 Ohm. The charging current is 1.0 A

Description : The primary turns of a 444 V/222 V, 50 Hz single-phase transformer with a core cross-sectional area of 100 cm2, and a maximum flux density of 1.0 T is (A) 100 (B) 200 (C) 222 (D) 400

Last Answer : The primary turns of a 444 V/222 V, 50 Hz single-phase transformer with a core cross-sectional area of 100 cm2, and a maximum flux density of 1.0 T is 200

Description : When secondary of a current transformer is open-circuited its iron core will be?

Last Answer : When secondary of a current transformer is open-circuited its iron core will be hot because of heavy iron losses taking place in it due to high flux density.

Description : A dc shunt generator has a speed of 800 rpm when delivering 20 A to the load at the terminal voltage of 220V. If the same machine is run as a motor it takes a line current of 20A from 220V supply. The speed of ... . (B) more than 800 rpm. (C) less than 800 rpm. (D) both higher or lower than 800 rpm.

Last Answer : (C) less than 800 rpm.

Description : Three bulbs are rating 40W 60W and 100W designed to work on 220V mains. Which bulb will burn most brightly if they are connected in series across 220 V mains? a. 40 W bulb b. 60 W blub c. 100 W blub d. all will burn equally brightly

Last Answer : a. 40 W bulb

Description : A 10 kVA, 400 V/200 V single phase transformer with 10% impedance draws a steady short-circuit line current of   (a) 250A (b) 50 A (c) 150 A (d) 350 A 

Last Answer : A 10 kVA, 400 V/200 V single phase transformer with 10% impedance draws a steady short-circuit line current of 250A