49 The open circuit test is carried out in a transformer to find the
A. Cu loss
B. Core loss
C. Total loss
D. Insulation resistance

1 Answer

Answer :

B. Core loss

Related questions

Description : [53] The iron loss of the transformer is negligible during short circuit test because A. The entire input is just sufficient to meet Cu losses only B. Flux produced is a small fraction of the normal flux C. Iron core becomes fully saturated D. Supply frequency is held constant

Last Answer : B. Flux produced is a small fraction of the normal flux

Description : 10] The main reason for generation of harmonics in a transformer could be A. Fluctuating load B. Poor insulation C. Mechanical vibrations D. Saturation of core

Last Answer : D) saturation of core

Description : 40 No load test on a transformer is carried out to find A. Copper loss B. magnetising current C. Magnetising current and loss D. Efficiency of the transformer

Last Answer : C. Magnetising current and loss

Description : 22 No load test on a transformer is carried out to find A. copper loss B. magnetising current C. Magnetising current and no load loss D. Efficiency of the transformer

Last Answer : C. Magnetising current and no load loss

Description : 48.During light loads, the transformer efficiency is low because A. Secondary output is low B. Transformer losses are high C. Fixed loss is high in proportion to the output D. Cu loss is small

Last Answer : C. Fixed loss is high in proportion to the output

Description : Why the open circuit test on a transformer is conducted at rated voltage?

Last Answer : A:The open circuit on a transformer is conducted at a rated voltage because core loss depends upon the voltage. This open circuit test gives only core loss or iron loss of the transformer.

Description : During open circuit test of a transformer?

Last Answer : During open circuit test of a transformer primary is supplied rated voltage.

Description : An open-circuit test on a transformer is conducted primarily to measure?

Last Answer : The open-circuit test in a transformer is used to measure

Last Answer : Primary side is low voltage side and secondary side is high voltage side.

Description : 13) In an ideal transformer A. windings have no resistance B. core has no losses C. core has infinite permeability D. all of the above

Last Answer : D. All of the above

Description : 43 The purpose of providing an iron core in a transformer is to A.Provide support to windings B. Reduce hysteresis loss C. decrease the reluctance of the magnetic path D. reduce eddy current losses

Last Answer : C. Decrease the reluctance of the magnetic path

Description : 19 Transformer cores are built up from laminations rather than from solid metal so that A. Oil penetrates the core more easily B. Eddy current loss is reduced C. Less lamination is required for the windings D. Turn ratio is higher than voltage ratio

Last Answer : B. Eddy current loss is reduced

Description : Which of the following properties is not necessarily desirable in the material for transformer core? A. Mechanical strength B. Low hysteresis loss C. High thermal conductivity D. High permeability

Last Answer : C) high thermal conductivity

Description : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is

Last Answer : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is 0.707

Description : When secondary of a current transformer is open-circuited its iron core will be?

Last Answer : When secondary of a current transformer is open-circuited its iron core will be hot because of heavy iron losses taking place in it due to high flux density.

Description : What are the necessary tests to determine the efficiency, voltage regulation, and temperature rise of winding & insulation of transformer?

Last Answer : 1.Direct loading test 2.Open circuit test 3. Short circuit test 4. Sumpner's or back to back test

Description : Explain about the open and short circuit tests on transformer?

Last Answer : A. Open circuit test (No load test) and short circuit test (full load test) are performed on a transformer to determine (i) Equivalent circuit of transformer (ii) Voltage ... determine copper loss in transformer at full load and parameters of approximate equivalent circuit of transformer.

Description : At full -load of a transformer, the iron loss and copper loss are 3000 W and 4000 W respectively. Then total loss at maximum efficiency is :  (A) 7000 W (B) 6000 W (C) 8000 W (D) 4000 W

Last Answer : At full -load of a transformer, the iron loss and copper loss are 3000 W and 4000 W respectively. Then total loss at maximum efficiency is : 6000 W

Description : 66 While conducting short-circuit test on a transformer the following side is short circuited A. High voltage side B. low voltage side C. primary side D. secondary side

Last Answer : B. Low voltage side

Description : 64)During the short-circuit test on a small transformer the frequency is increased from 50-200Hz. The copper losses will increase by a factor of A. 16 B. 4 C. 1 D. 1/4

Last Answer : A) 16

Description : 30 In performing the short circuit test of a transformer A. high voltage is usually short circuited B. low voltage side is usually short circuited C. any side is short circuited with preference D. none of the above

Last Answer : B. Low voltage side is usually short circuited

Description : During short circuit test iron losses are negligible because A. The current on secondary side is negligible B. The voltage on secondary side does not vary C. The voltage applied on primary side is low D. Full-load current is not supplied to the transformer

Last Answer : C) the voltage applied on primary side is low

Description : During short circuit test iron losses are negligible because A. The current on secondary side is negligible B. The voltage on secondary side does not vary C. The voltage applied on primary side is low D. Full-load current is not supplied to the transformer

Last Answer : C) the voltage applied on primary side is low

Last Answer : In short circuit test of transformer the low voltage side is short circuited . On high voltage side the voltmeter is connected in parallel and ammeter in series and also a wattmeter is ... circuit test is done for determining impedance and losses. In this test iron losses is neglected.

Description : The area of the yoke in a transformer is taken 15 to 20% larger than that of the core. Why?

Last Answer : By keeping yoke area 15-20% higher ,the flux density in the yoke is reduced, resulting into reduction in iron losses for yoke. The reduced core area results working flux density and needed to increase the number of turns.

Description : What is the purpose of laminating the core in a transformer?

Last Answer : In order to minimize eddy current loss.

Description : Where is core type and shell type construction suitable for a transformer?

Last Answer : Core type transformers are popular in High voltage applications like Distribution transformers, Power transformers, and obviously auto transformers. Where as, Shell type transformers are ... voltage applications like transformers used in electronic circuits and power electronic converters etc

Description : What are the advantages of shell type transformer over core type transformers?

Last Answer : In shell type transformers the coils are well supported on the all sides and so they can withstand higher mechanical stresses developed during short circuit conditions. Also the leakage reactance will be less in shell type transformers.

Description : 72 Harmonics in transformer result in A. Increased core losses B. Increased I2R losses C. Magnetic interference with communication circuits D. All of the above

Last Answer : D. All of the above

Description : 46 The core used in high frequency transformer is usually A. Copper core B. Cost iron core C. Air core D.Mid steel core

Last Answer : C. Air core

Description : 45 The function of conservator in a transformer is A. To protect against internal fault B. To reduce copper as well as core losses C. To cool the transformer oil D. To take care of the expansion and contraction of transformer oil due to variation of temperature of surroundings

Last Answer : D. To take care of the expansion and contraction of transformer oil due to variation of temperature of surroundings

Description : 27] In a transformer, the leakage flux of each winding is proportional to the current in that winding because A. Ohm's law applies to magnetic circuits B. Leakage paths do no saturate C. the two windings are electrically isolated D. mutual flux is confined to the core

Last Answer : B. Leakage path do not saturate

Description : 8 The transformer core is laminated to A. Reduce the copper losses B. Reduce the core losses C. Reduce the eddy current losses D. None of the above

Last Answer : C. Reduce the eddy current losses

Description : 12] Which is not the basic element of the transformer? A. core B. primary winding C. secondary winding D. mutual flux

Last Answer : D. Mutual flux

Description : Material used for construction of transformer core is usually A. 0.4mm to 0.5 mm B. 4mm to 5 mm C. 14mm to 15 mm D. 25mm to 40 mm

Last Answer : d) 25mm to 40mm

Description : State any four characteristics of core type transformer.

Last Answer : Characteristics of core type transformer: i) It has one window. ii) It has one magnetic circuit. iii) Core surrounds the winding. iv) Average length of core is more. v) Area of cross ... Better cooling for winding. vii) Mechnical strength is comparatively less. viii) Repair and maintenance is easy.

Description : The core construction is like spokes of a wheel in following transformer:  (A) Berry Type Transformer (B) Core Type Transformer (C) Shell Type Transformer (D) None of the above

Last Answer : The core construction is like spokes of a wheel in following transformer:  Berry Type Transformer

Description : The desirable properties of transformer core material are  (1) low permeability and low hysteresis loss. (2) high permeability and high hysteresis loss. (3) high permeability and low hysteresis loss. (4) low permeability and hysteresis loss.

Last Answer : The desirable properties of transformer core material are high permeability and low hysteresis loss.

Description : The main purpose of using core in a transformer is to (A) decrease iron losses (B) eliminate magnetic hysteresis (C) reduce reluctance of the common magnetic circuit (D) prevent eddy current loss

Last Answer : Reduce Relucatnce of the common magnetic circuit.

Last Answer : The purpose of providing an iron core in a transformer is to decrease the reluctance of the magnetic path.

Last Answer : The purpose of providing iron core in a step-up transformer is to decrease the magnitude of magnetizing current.

Last Answer : Material used for construction of transformer core is usually silicon steel.

Last Answer : The core used in high frequency transformer is usually air core .

Description : The size of a transformer core will depend on?

Last Answer : The size of a transformer core will depend on frequency and area of the core.

Description : Reduction in core losses and increase in permeability are obtained with transformer employing?

Last Answer : Reduction in core losses and increase in permeability are obtained with transformer employing core built-up of laminations of cold rolled grain oriented steel.

Description : Why does the core of a transformer need to be laminated?

Last Answer : Transformer cores are laminated to reduce eddy current loss.

Last Answer : Transformer core is laminated to reduce Eddy current losses.