The voltage regulation of an alternator having 0.75 leading p.f. load, no-load induced e.m.f. of 2400V and rated terminal voltage of 3000V is ————————————— 

A) 20% B) —20% C) 150 D) -26.7
-20%

1 Answer

Answer :

-20
can you explain ?

Related questions

Description : In a transformer the voltage regulation will be zero when it operates at (A) unity p.f. (B) leading p.f. (C) lagging p.f. (D) zero p.f. leading.

Last Answer : (B) leading p.f.

Description : Motorization of an alternator is undesirable because _____________. A. the alternator will be damaged B. it puts an additional load on the bus C. high voltage pulses are induced in the bus D. all of the above

Last Answer : Answer: B

Description : A transformer has negative voltage regulation when its load power factor is- (a) Zero (b) Unity (c) Leading (d) Lagging

Last Answer : Ans: C

Description : 51 A transformer has negative voltage regulation when its load power factor is A. Zero B. Unity C. Leading D. Lagging

Last Answer : C. leading

Description : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m.

Last Answer : (D) 75 r.p.m.

Description : An alternator is delivering rated current at rated voltage and 0.8 power-factor lagging case. If it is required to deliver rated current at rated voltage and 0.8 power-factor leading, the required excitation will be (A) less. (B) more. (C) more or less. (D) the same.

Last Answer : Ans: B Over excitation gives leading power factor and under excitation gives lagging p.f .

Description : What are the test data required for predetermining the voltage regulation of an Alternator by MMF method?

Last Answer : Data required for MMF method are : · Effective resistance per phase of the 3-phase winding R · Open circuit characteristic (OCC) at rated speed/frequency · Short circuit characteristic (SCC) at rated speed/frequency

Description : What are the advantages and disadvantages of estimating the voltage regulation of an Alternator by EMF method?

Last Answer : Advantages: · Simple no load tests (for obtaining OCC and SCC) are to be conducted · Calculation procedure is much simpler Disadvantages: · The value of voltage regulation obtained by this method is always higher than the actual value

Description : Name the various methods for predetermining the voltage regulation of 3-phase Alternator.

Last Answer : The following are the three methods which are used to predetermine the voltage regulation of smooth cylindrical type Alternators · Synchronous impedance / EMF method · Ampere-turn / MMF method · Potier / ZPF method

Description : Define the term voltage regulation of Alternator.

Last Answer : The voltage regulation of an Alternator is defined as the change in terminal voltage from no-load to load condition expressed as a fraction or percentage of terminal voltage at load condition ; the speed and excitation conditions remaining same.

Description : If the excitation of an alternator operating in parallel is decreased below normal, its _____________. A. power factor will change in the lagging direction B. power factor will change in the leading direction C. ampere load will be greatly increased D. kilowatt load will be greatly decreased

Last Answer : Answer: B

Description : The division of kilowatt load between two paralleled alternators is determined by the _____________. A. amount of field excitation of the leading machine B. load-speed characteristics of the governors C. amount of field excitation to the lagging machine D. type of alternator

Last Answer : Answer: B

Description : The division of kilowatt load between two paralleled alternators is determined by the _____________. A. amount of field excitation to the leading machine B. load-speed characteristics of the governors C. amount of field excitation to the lagging machine D. number of field poles per alternator

Last Answer : Answer: B

Description : Magnitude of induced e.m.f is proportional to A. rate of change of current B. rate of change of voltage C. rate of change of magnetic flux linkage D. rate of change of resistance

Last Answer : rate of change of magnetic flux linkage

Description : An Alternator is found to have its terminal voltage on load condition more than that on no load. What is the nature of the load connected?

Last Answer : The nature of the load is of leading power factor , load consisting of resistance and capacitive reactance.

Description : A two-winding single phase transformer has a voltage regulation of 4.5% at full-load and unity power-factor. At full-load and 0.80 power-factor lagging load the voltage regulation will be (A) 4.5%. (B) less than 4.5%. (C) more than 4.5%. (D) 4.5% or more than 4.5%.

Last Answer : (C) more than 4.5%.

Description : If the no load voltage of a certain generator is 220V and the rated load voltage is 200V, then the voltage regulation is: a. 1% b. 10% c. 20V d. 9%

Last Answer : If the no load voltage of a certain generator is 220V and the rated load voltage is 200V, then the voltage regulation is: a. 1% b. 10% c. 20V d. 9%

Description : A straight wire of length 0.20 m moves at a steady speed of 3.0 m s-1 at right angles to the magnetic field of flux density 0.10 T. The e.m.f induced across ends of wire is A. 0.5 V B. 0.06 V C. 0.05 V D. 0.04 V

Last Answer : 0.06 V

Description : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be?

Last Answer : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be 580 V.

Description : Define armature reaction in an alternator. Explain the effect of armature reaction at various P.F. of loads of alternator.

Last Answer : Armature Reaction: The effect of armature flux on main flux is called as armature reaction.  Armature Reaction at Various Power Factors: When armature is loaded, the armature flux modifies ... lagging p.f. For capacitive loads the effect of flux is partly distorting and partly strengthening.

Description : A solid shaft has diameter 80 mm. It is subjected to a torque of 4 KNm. The maximum shear stress induced in the shaft would be (a) 75/p N/mm2 (b) 250/p N/mm2 (c) 125/p N/mm2 (d) 150/p N/mm2

Last Answer : (c) 125/p N/mm2

Description : To remove an alternator operating in parallel with another unit from the main electrical bus, you must FIRST _________. A. adjust the power factor on both units B. set the desired voltage on ... C. open the circuit breaker on the outgoing alternator D. remove the load from the outgoing alternator

Last Answer : Answer: D

Description : If field excitation is suddenly lost to an alternator operating in parallel, that alternator will _____________. A. supply excessive current to the bus B. operate at the same load, but with reduced voltage C. lose its load and tend to overspeed D. become overloaded and slow down

Last Answer : Answer: C

Description : A change in field excitation of an alternator operating in parallel will cause a change in its _____________. A. alternator frequency B. kilowatt load C. voltage output D. all of the above

Last Answer : Answer: C

Description : The standard method of controlling the output voltage of a 440 volt, 60 Hz, AC generator is accomplished by adjusting the ____________. A. prime mover speed droop B. number of poles C. alternator field excitation D. load on the alternator

Last Answer : Answer: C

Description : The output voltage of a 440 volt, 60 Hz AC generator is controlled by the ______________. A. load on the alternator B. load on the prime mover C. speed of the prime mover D. exciter output voltage

Last Answer : Answer: D

Description : The output voltage of a 440 volt, 60 hertz, AC generator is controlled by the _____________. A. prime mover speed B. exciter output voltage C. load on the alternator D. number of poles

Last Answer : Answer: B

Description : .Gene regulation governing lactose operon of E.coli that involves the lac I gene product is (a) negative and repressible because repressor protein prevents transcription (b) feedback inhibition ... be induced by lactose (d) negative and inducible because repressor protein prevents transcription.

Last Answer : (d) negative and inducible because repressor protein prevents transcription.

Description : Gene regulation governing lactose operon of E.coli that involves the lac I gene product is (a) negative and repressible because repressor protein prevents transcription (b) feedback inhibition ... be induced by lactose (d) negative and inducible because repressor protein prevents transcription.

Last Answer : (d) negative and inducible because repressor protein prevents transcription.

Description : The instantaneous reduction in voltage of an AC generator, resulting from an increase in load, and prior to the automatic voltage regulator correcting the situation, is called voltage ____________. A. droop B. drop C. dip D. regulation

Last Answer : Answer: C

Description : Load regulation is a measure of a power supplies ability keep a constant output under conditions of changing A) Line voltage B) Current demand C) Temperature D) Oscillator frequency.

Last Answer : A) Line voltage

Description : In a transformer, zero voltage regulation at full load is   (a)Not possible   (b) Possible at unity power factor load   (c) Possible at leading power factor load   (d) Possible at lagging power factor load

Last Answer : In a transformer, zero voltage regulation at full load is Possible at leading power factor load 

Description : A transformer has negative voltage regulation when its load power factor is   (1) Zero (2) Unity (3) Leading (4) Lagging

Last Answer : 0

Description : Identify the increasing order of voltage regulation of the following dc generators a same load :  (A) differential compound, shunt and under compound  (B) shunt, differential compound and ... C) under compound, shunt and differential compound  (D) shunt, under compound and differential compound

Last Answer : Identify the increasing order of voltage regulation of the following dc generators a same load : under compound, shunt and differential compound 

Description : A two -winding single phase transformer has a voltage regulation of 4.5% at full - load and unity power -factor. At full -load and 0.80 lagging power-factor, the voltage regulation will be: (A) 4.5% (B) less than 4.5% (C) more than 4.5% (D) none of the above

Last Answer : A two -winding single phase transformer has a voltage regulation of 4.5% at full - load and unity power -factor. At full -load and 0.80 lagging power-factor, the voltage regulation will be: more than 4.5%

Description : Negative voltage regulation is indicative that the load is?

Last Answer : Negative voltage regulation is indicative that the load is capacitive.

Description : Minimum voltage regulation occurs when the power factor of the load is?

Last Answer : Minimum voltage regulation occurs when the power factor of the load is leading.

Description : A d.c. shunt motor runs at no load speed of 1140 r.p.m. At full load, armature reaction weakens the main flux by 5% whereas the armature circuit voltage drops by 10%. The motor full load speed in r.p.m. is (A) 1080 (B) 1203 (C) 1000 (D) 1200

Last Answer : (A) 1080

Description : Mention the factors on which the magnitude of the e.m.f induced in the transformer depends.

Last Answer : 1) E.m.f in the primary coil 2) Number of turns in the primary coil 3) Number of turns in the secondary coil 4) The core material

Description : E.M.F can be induced in a circuit by A. changing magnetic flux density B. changing area of circuit C. changing the angle D. all of above

Last Answer : all of above

Description : The left hand rule correlates to (a) current, induced e.m.f. and direction of force on a conductor (b) magnetic field, electric field and direction of force on a conductor (c) self induction, ... and direction of force on a conductor (d) current, magnetic field and direction of force on a conductor

Last Answer : (d) current, magnetic field and direction of force on a conductor

Description : The introduction of interpoles in between the main pole improves the performance of d.c. machines, because (A) The interpole produces additional flux to augment the developed torque. (B) The flux waveform is ... armature is removed. (D) A counter e.m.f. is induced in the coil undergoing commutation.

Last Answer : Ans: D Counter e.m.f is produced, it neutralizes the reactive emf.

Description : Which of the following quantity maintains the same direction whether a D.C. machine runs as a generator or as a motor a. Induced e.m.f. b. Armature Current c. Field Current d. Supply Current  

Last Answer : Which of the following quantity maintains the same direction whether a D.C. machine runs as a generator or as a motor a. Induced e.m.f. b. Armature Current c. Field Current d. Supply Current  

Description : Which law states that induced e.m.f and current always opposes the cause producing them?

Last Answer : Lenz's law states that induced e.m.f and current always opposes the cause producing them.

Description : These self inductance of a circuit is defined as twice the work done against the induced e.m.f. on establishing unit current in the coil. If the current to be established in the coil is doubled, the work done ... induced e.m.f. will be  1. Doubled  2. Halved  3. four times  4. Quarter times 

Last Answer : These self inductance of a circuit is defined as twice the work done against the induced e.m.f. on establishing unit current in the coil. If the current to be established in the coil is doubled, the work done against the induced e.m.f. will be four times

Description : The e.m.f. induced in the primary of a transformer:  (A) is in phase with the flux (B) lags behind the flux by 90 degree (C) leads the flux by 90 degree (D) is in phase opposition to that of flux

Last Answer : The e.m.f. induced in the primary of a transformer: leads the flux by 90 degree 

Last Answer : For the production of induced e.m.f. field system of an electric machine may be on stator or rotor.

Last Answer : When a magnet is in motion relative to a coil the induced e.m.f. does not depend upon resistance of the coil.

Description : The induced e.m.f. in the armature conductors of a d.c. motor is?

Last Answer : The induced e.m.f. in the armature conductors of a d.c. motor is sinusoidal.

Description : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be?

Last Answer : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be zero.