Upon increasing the transmission voltage, volume of the conductor will: 

(A) increase (B) not change (C) decrease (D) increase for some time and then decrease

1 Answer

Answer :

Upon increasing the transmission voltage, volume of the conductor will: decrease

Related questions

Description : As the voltage of transmission increases, the volume of conductor (A) increases. (B) does not change. (C) decreases. (D) increases proportionately.

Last Answer : Ans: C Decreases due to skin effect.

Description : ECE Board Exam March 1996 The characteristics impedance of a transmission line does not depend upon its ________. A. conductor spacing B. conductor diameter C. length D. conductor radius

Last Answer : C. length

Description : The thickness of the layer of insulation on the conductor, in cables, depends upon (a) Reactive power (b) Power factor (c) Voltage (d) Current carrying capacity

Last Answer : (c) Voltage

Description : Which of the following is the demerit of a 'constant voltage transmission system' ? (a) Increase of short-circuit current of the system (b) Availability of steady voltage at all loads at ... of carrying increased power for a given conductor size in case of long-distance heavy power transmission

Last Answer : (a) Increase of short-circuit current of the system

Description : Constant voltage transmission entails the following disadvantage (a) large conductor area is required for same power transmission (b) short-circuit current of the system is increased (c) either of the above (d) none of the above

Last Answer : (b) short-circuit current of the system is increased

Description : Which of the following is the demerit of a 'constant voltage transmission system' ? (a) Increase of short-circuit current of the system (b) Availability of steady voltage at all loads at ... of carrying increased power for a given conductor size in case of long-distance heavy power transmission

Last Answer : (a) Increase of short-circuit current of the system

Description : Select insulating materials for following parts : (i) Insulation between heating element and base plate of electric iron. (ii) Insulation used over copper or aluminium conductor used for making coils. (iii) Transformer bushings. (iv) Insulation between transmission line and pole.

Last Answer : Parts Insulating Materials  Insulation between heating element and base plate of electric iron. Mica Insulation used over copper or aluminium conductor used for making coils.  ... Transformer bushings Porcelain  Insulation between transmission line and pole. Porcelain

Description : Compare pin type and suspension insulators on given points: (i) Position of insulator on cross arm. (ii) Position of conductor on insulator. (iii) Reaction on cross arm. (iv) Possibility of ... Replacement cost (vi) Maximum voltage level (vii) Effect on height of supporting structure. (viii) Life 

Last Answer : S.No  Points Pin Type insulator Suspension or Disc Type insulator 1 Position of insulator on cross arm It is fixed on top of cross arm by using galvanized steel pin. So it is ... so to maintain minimum ground clearance height of pole increase.  8 Life Less More

Description : Give reason for the following observation (L-III) (a)- The tendency for catenation decreases down the group in group 14 (b)- The decreasing stability of+3 oxidation state with increasing atomic no. in group 13. (c)- Molten aluminum bromide is a poor conductor of electricity.

Last Answer : Ans. -(a) it is due to decrease in bond dissociation energy which is due to increase in atomic size C-C > Si-Si >Ge-Ge>Sn-Sn>Pb-Pb. (b)- It is due to inert pair effect. (c)- Molten AlBr3 is poor conductor of electricity because it is covalent compound.

Description : Where do the electrical charges reside in a charged conductor? (1) at the core (2) throughout the body (3) depended upon the nature of the body (4) outer surface of the body

Last Answer : (4) outer surface of the body Explanation: In all conductors, charges reside on the surface. The reason for this is that conductors have free electrons, that is, the electrons are loosely ... field just, outside the conductor is perpendicular to the surface and that the field inside is zero.

Description : Where do the electrical charges reside in a charged conductor? (1) at the core (2) throughout the body (3) depended upon the nature of the body (4) outer surface of the body

Last Answer : (4) outer surface of the body Explanation: In all conductors, charges reside on the surface. The reason for this is that conductors have free electrons, that is, the electrons are loosely ... field just, outside the conductor is perpendicular to the surface and that the field inside is zero.

Description : The existing resistance of a conductor is dependent upon its length, cross-sectional area, _____________. A. temperature and insulation B. material and insulation C. resistive coefficient and material D. material and temperature

Last Answer : Answer: D

Description : Resistance of a conductor depends upon a. nature of conductor b. dimension of conductor c. physical state of the conductor d. all of above

Last Answer : d. all of above

Description : Where do the electrical charges reside in a charged conductor? (1) at the core (2) throughout the body (3) depended upon the nature of the body (4) outer surface of the body

Last Answer : outer surface of the body

Description : Voltage required to operate a neon-sign tube depends upon

Last Answer : Voltage required to operate a neon-sign tube depends upon length of the tube

Description : T.V. transmission cannot cover a very large area because _____ A. The strength of T.V. waves is very limited B. Picture cannot be transmitted clearly after a specific distance C. The shape of the earth is spherical D. The air is not a good conductor of light and sound/waves

Last Answer : ANSWER: C

Description : Copper wires are generally used for electrical power transmission instead of iron wire because (1) copper is cheaper than iron (2) copper is lighter than iron (3) copper is a better conductor of electricity than iron (4) copper can take higher power than iron

Last Answer : (3) copper is a better conductor of electricity than iron Explanation: Copper is generally preferred for electrical power transmission instead of iron because of its high electrical conductivity and low resistivity.

Description : What determines the velocity factor in a transmission line? A. The termination impedance B. The line length C. Dielectrics in the line D. The center conductor resistivity

Last Answer : C. Dielectrics in the line

Description : What determines the velocity factor in transmission line? A. The center conductor resistivity B. Dielectrics in the line C. The termination impedance D. The line length

Last Answer : B. Dielectrics in the line

Description : The outer conductor of a coaxial transmission line is always grounded at the A. Input only B. Input and output C. Output only D. Point of high SWR

Last Answer : B. Input and output

Description : Termination means A. result of disconnecting a line from a transmitter B. result of cutting both ends of a conductor C. looking back impedance of a line with no load D. load connected to the output end of a transmission line

Last Answer : D. load connected to the output end of a transmission line

Description : T.V. transmission cannot cover a very large area because A. the strength of T.V. waves is very limited B. picture cannot be transmitted clearly after a specific distance C. the shape of the earth is spherical (Answer) D. the air is not a good conductor of light and sound/waves

Last Answer : C. the shape of the earth is spherical (Answer)

Description : The two conductors of a transmission line carry equal current I in opposite directions. The force on each conductor is (a) proportional to 7 (b) proportional to X (c) proportional to distance between the conductors (d) inversely proportional to I

Last Answer : (b) proportional to X

Description : ACSR (Aluminium Conductor Steel Reinforced) are used as (A) over head transmission lines. (B) super conductors. (C) fuse (D) underground cables.

Last Answer : (A) over head transmission lines.

Description : Copper wires are generally used for electrical power transmission instead of iron wire because : (1) copper is cheaper than iron (2) copper is lighter than iron (3) copper is a better conductor of electricity than iron (4) copper can take higher power than iron 

Last Answer : copper is a better conductor of electricity than iron

Description : Why two thin shirts can keep us warmer than a single thick shirt in winter ? (1) Two thin shirts become thicker so prevent transmission of heat (2) Air layer between two shirts works as good conductor (3) Air layer between two shirts behaves like insulating media (4) No radiation of heat takes place

Last Answer : Air layer between two shirts behaves like insulating media

Description : An overhead transmission line has a span of 260 m. The weight of the conductor is 0.68 kg/m. The maximum allowable tension in the line is 1550 kg. Maximum sag of the line should be (a) 5.8 m (b) 4.6 m (c) 2.7 m (d) 3.7 m 

Last Answer : Maximum sag = (l^2)/8c So c = T/W c = 1550/0.68 c= 2279.4 Now Maximum sag = (260^2)/8(2279.4) = 3.7 (d)

Description : The line conductor of a transmission line has an overall diameter of 19.53 mm, weight 0.844 kg/m and an ultimate breaking strength of 7950 kg. If the factor of safety is to be 2, when conductor ... .5 kg/m. What is the vertical sag, corresponding to this loading for a 300 m span level supports?

Last Answer : The line conductor of a transmission line has an overall diameter of 19.53 mm, weight 0.844 kg/m and an ultimate breaking strength of 7950 kg. If the factor of safety is to be 2, when conductor ... 5 kg/m. 5.22 m is the vertical sag, corresponding to this loading for a 300 m span level supports.

Description : A transmission line conductor at a river crossing is supported from two towers at height. of 30 m and 90m, above water level. The horizontal distance between the towers is 270m, if the tension in ... . What is the clearance between the conductor and the water at a point midway between the towers?

Last Answer : A transmission line conductor at a river crossing is supported from two towers at height. of 30 m and 90m, above water level. The horizontal distance between the towers is 270m, if the tension ...  54.94 m is the clearance between the conductor and the water at a point midway between the towers.

Description : why we use aluminium conductor and not copper in transmission lines ?

Last Answer : Because copper conductor are costlier than aluminium conductor

Description : What happens insulators when high voltage passes through transmission lines whether it breaks or lose it's insulating property?

Last Answer : I think it will breaks when it crosses breakdown voltage .

Description : State standard voltage in India for the following : (i) Generation Voltage (ii) Primary Transmission Voltage

Last Answer : i. Generation Voltage : 3.3KV, 6.6KV,11KV and 17.5 KV  ii. Primary Transmission voltage :- 220 KV, 400KV, 765 KV (750 KV) 

Description : The permissible voltage variation in transmission and distribution system is:  (A) ± 0.1% (B) ± 1% (C) ±10% (D) ± 25%

Last Answer : The permissible voltage variation in transmission and distribution system is: ±10%

Description : Bundled conductors are mainly used in high voltage overhead transmission lines to (a) Reduce line loss (c) Reduce corona (b) Reduce harmonics (d) Increase strength

Last Answer : Bundled conductors are mainly used in high voltage overhead transmission lines to Reduce corona 

Last Answer : Transmission lines use high voltage to reduce the amount of power loss over long distance. This power loss can come from large current running through the cable due to the resistance of the cable conductor. Stepping up the voltage reduces the amount of current through transmission lines.

Description : Name the plant growth regulator which upon spraying on sugarcane crop, increases the length of stem, thus increasing the yield of sugarcane crop. (a) Cytokinin (b) Gibberellin (c) Ethylene (d) Abscisic acid

Last Answer : (b) Gibberellin

Description : Resistance of a wire on increasing its temperature will a. increase with rise in temperature b. decrease with rise in temperature c. will remain same d. depends upon altitude of experimentation

Last Answer : a. increase with rise in temperature

Description : Local anesthetics: A. Inhibit transmission of nerve impulses by increasing sodium membrane permeability and the displacement of ionized calcium. B. Are classified as amides or esters. C. Produce peripheral vasodilation. D. Are weak acids.

Last Answer : Answer: BC DISCUSSION: Local anesthetics act within the nerve membrane, where they inhibit transmission of nerve impulses by reducing sodium membrane permeability and the displacement of ionized ... based on this bond. All local anesthetics except cocaine produce vasodilatation and are weak bases

Description : Which ARQ mechanism deals with the transmission of only damaged or lost frames despite the other multiple frames by increasing the efficiency & its utility in noisy channels? a. GoBackN ARQ b. Selective Repeat ARQ c. StopandWait ARQ d. All of the above

Last Answer : b. Selective Repeat ARQ

Description : The interaction between a transmission line and communication line is minimized by (a) transposing transmission as well as communication lines (b) increasing the height of the transmission line tower (c) increasing the distance between the two lines (d) all of the above

Last Answer : (d) all of the above

Description : I have a cottage about 100 meters from high voltage wires. Is it possible that he will hit me during a storm if I don't have a lightning conductor? It would lead to those wires, wouldn't it?

Last Answer : Sometimes the lightning must go; On the other hand, lightning is a discharge of such high voltage and so high currents that it can easily beat even the cottage 100 m away. Personally, ... include inspection (by an inspection technician), the service interval for subsequent inspections is 5 years.

Description : To properly use a hook-on-type volt/ammeter to check current flow, you must FIRST _____________. A. de-energize the circuit to allow connection of the instrument in series B. hook the jaws ... test leads to the appropriate terminals D. short the test leads and calibrate the instrument to zero

Last Answer : Answer: B

Description : In the left hand rule, forefinger always represents (a) voltage (b) current (c) magnetic field (d) direction of force on the conductor

Last Answer : (c) magnetic field

Description : In a cable the voltage stress is maximum at (a) sheath (6) insulator (e) surface of the conductor (d) core of the conductor

Last Answer : (d) core of the conductor

Description : PVC stands for (a) polyvinyl chloride (b) post varnish conductor (c) pressed and varnished cloth (d) positive voltage conductor (e) none of the above

Last Answer : (a) polyvinyl chloride

Description : Is it considered safe for a person to touch any energized low-voltage conductor with the bare hand?

Last Answer : NEVER! All energized electric circuits should be considered potentially dangerous.

Description : The size of a conductor used in power cables depends on the (A) operating voltage. (B) power factor. (C) current to be carried. (D) type of insulation used.

Last Answer : (C) current to be carried.

Description : Is there a negative effect upon adding new transmission fluid to the old one with out a flush?

Last Answer : There is no negative effects. i am a mechanic of thirty years.

Description : Quality of transmission depends upon (1) Nature of signal only (2) Nature of medium only (3) Both (1) and (2) (4) Neither A nor B

Last Answer : (3) Both (1) and (2) Explanation: Quality of transmission is governed both by nature of signal and nature of communication channel/medium.

Description : Arrange the following in the order of increasing volume `:` (A) Tidal volume (B ) Residual volume (C ) Inspiratory reserve volume (D ) Vital capacity

Last Answer : Arrange the following in the order of increasing volume `:` (A) Tidal volume (B ) Residual volume (C ) Inspiratory reserve ... , D, C, B D. A, D, B, C