Armature shunting method of speed control of dc shunt motor is preferred over annature resistance method due to: 

(1) Better speed regulation (2) Less loss in external resistance (3) Simplicity in control circuit (4) Reduced cost of controller

1 Answer

Answer :

Armature shunting method of speed control of dc shunt motor is preferred over annature resistance method due to: Better speed regulation.

Related questions

Description : As compared to shunt and compound DC motors, the series DC motor will have the highest torque because of its comparatively ____________ at the start. (A) Lower armature resistance. (B) Stronger series field. (C) Fewer series turns. (D) Larger armature current.

Last Answer : (D) Larger armature current.

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Description : With the help of neat diagrams,explain the following methods of speed control in DC series motor. i) Field diverter method. ii) Armature diverter method.

Last Answer : (i) Field diverter method: - Resistance connected in parallel with field winding -By adjusting this resistance current can by diverted from field winding -Thus field current decreases and the speed can be ... decreased, the flux must increase and hence speed is decreased than the rated speed.

Description : If a DC motor runs faster than designed, with all other conditions being normal, the possible cause could be a/an ______________. A. shorted shunt field coil B. open armature coil C. reversed commutating pole D. overload

Last Answer : Answer: A

Description : An open armature connection in a DC propulsion motor could be caused by ____________. A. low-load operation B. clogged ventilation ducts C. sparking at the brushes D. a grounded shunt field coil

Last Answer : Answer: B

Description : The torque, in a _____________is proportional to the square of the armature current (A) DC shunt motor (B) stepper motor (C) 2-phase servomotor (D) DC series motor

Last Answer : (D) DC series motor

Description : A 50 kW dc shunt is loaded to draw rated armature current at any given speed. When driven  (i) at half the rated speed by armature voltage control and (ii) at 1.5 times the rated speed by field control, the respective output powers ... kW in (i) and 75 kW in (ii) (D) 50 kW in (i) and 50 kW in (ii)

Last Answer : A 50 kW dc shunt is loaded to draw rated armature current at any given speed. When driven  (i) at half the rated speed by armature voltage control and (ii) at 1.5 times the rated speed by field control, the respective output ... kW in (i) and 75 kW in (ii) (D) 50 kW in (i) and 50 kW in (ii)

Description : A d.c. shunt motor runs at no load speed of 1140 r.p.m. At full load, armature reaction weakens the main flux by 5% whereas the armature circuit voltage drops by 10%. The motor full load speed in r.p.m. is (A) 1080 (B) 1203 (C) 1000 (D) 1200

Last Answer : (A) 1080

Description : The no load speed of a d.c. shunt motor is 1140 rpm. At full load, the armature reaction weakens the main flux by 5% whereas the armature circuit voltage drops by 10%. The motor full load speed in rpm will be: (A) 1080 (B) 1203 (C) 1000 (D) 1200

Last Answer : The no load speed of a d.c. shunt motor is 1140 rpm. At full load, the armature reaction weakens the main flux by 5% whereas the armature circuit voltage drops by 10%. The motor full load speed in rpm will be: 1080

Description : Moving the rheostat handle shown in the illustration, that is used to control a DC generator, towards the 'raise' direction will increase the _____________. EL-0030 A. field resistance B. armature resistance C. armature speed D. line voltage

Last Answer : Answer: D

Description : Why Speed Control of Induction Motor is difficult compared to DC shunt motor?

Last Answer : Answer: Speed Control of DC shunt motor can be possible by providing resistance in the armature and field circuits and varying the resistors speed changes can be carried out over a wide range. ... employed. Care should be taken that in the process efficiency and power factor should be maintained.

Description : Give two basic speed control scheme of DC shunt motor?

Last Answer : Answer: 1. By using flux control method: in this method a rheostat is connected across the field wdg to control the field current. So by changing the current the flux produced by the field wdg can ... ) can be varied, and since speed is directly proportional to Eb-IaRa the speed can be controlled.

Description : If field current is decreased in shunt dc motor, the speed of the motor (a) remains same. (b) increases. (c) decreases. (d) none of the above.

Last Answer : increases

Description : Why are drum-type armatures preferred over the Gramme ring armature in modern dc generators?

Last Answer : Drum-type armatures are more efficient, because flux lines are cut by both sides of each coil.

Description :  If shunt generator delivers 100 A at 200 V, and the resistance of the shunt field and armature are 100 ohm and 0.01 ohm respectively, the generated e.m.f. will be : -  a) 212 V b) 205 V c) 210 V d) 201.02 V

Last Answer :  If shunt generator delivers 100 A at 200 V, and the resistance of the shunt field and armature are 100 ohm and 0.01 ohm respectively, the generated e.m.f. will be : - 201.02 V

Description : The purpose of resistor bank 'R1-R5' in the winch circuit shown in the illustration is to ______________. EL-0102 A. limit armature current in lower and 'series field' current in hoist to ... required speeds D. regulate the strength of the brake solenoid 'B1-B2' in both directions of operation

Last Answer : Answer: C

Description : A shunt-wound DC generator is one in which the shunt field windings are in parallel with the _____________. A. commutator B. brushes C. armature D. all of the above

Last Answer : Answer: D

Description : A DC shunt generator has its field windings connected in _____________. A. series with the series windings B. parallel with the field rheostat C. series with the armature windings D. parallel with the armature windings

Last Answer : Answer: D

Description : Which of the following types of DC motors has its field connected in parallel with its armature? A. Counter EMF B. Shunt C. Salient pole D. Series

Last Answer : Answer: B

Description : An open in the armature of a DC motor is suspected, but is not found by visual inspection of the commutator. The next step in troubleshooting this problem is to ________________. A. conduct a ... windings C. conduct an insulation resistance test of the armature D. test the commutator for a ground

Last Answer : Answer: A

Description : The armature resistance of a permanent magnet dc motor is 0.8 Ohm. At no load, the motor draws 1.5 A from a supply voltage of 25 V and runs at 1500 rpm. The efficiency of the motor while it is operating on load at 1500 ... .5 A from the same source will be  (A) 48.0% (B) 57.1% (C) 59.2% (D) 88.8%

Last Answer : The armature resistance of a permanent magnet dc motor is 0.8 Ohm. At no load, the motor draws 1.5 A from a supply voltage of 25 V and runs at 1500 rpm. The efficiency of the motor while it is operating on load at 1500 rpm drawing a current of 3.5 A from the same source will be 48.0%

Description : The advantage(s) of the method of D.C. motor speed control shown in the illustration is/are ______________. EL-0101 A. elimination of armature starting resistor losses B. elimination of speed instability with variable loads C. the ease of reversing motor direction D. all of the above

Last Answer : Answer: D

Description : Which of the listed electrical devices is represented by the symbol shown in the illustration? EL-0055 A. Fixed resistance resistor B. Coil with magnetic core C. DC motor or generator shunt field D. Transformer

Last Answer : Answer: D

Description : The counter EMF of a DC motor is maximum when the _________. A. motor is at rated speed B. armature is not turning C. motor is almost up to rated speed D. armature has just begun to turn

Last Answer : Answer: A

Description : The counter EMF produced in the windings of a DC motor is 'zero' when the ____________. A. armature has just begun to turn B. armature is not turning C. motor is almost up to rated speed D. motor is at rated speed

Last Answer : Answer: B

Description : A dc cumulatively compounded motor delivers rated load torque at rated speed. If series field is short circuited, then the armature current and speed will a) Both increases b) Both decreases c) Increases and decreases d) Decreases and increases

Last Answer : Ans: Both increases

Description : One method of testing for a reversed shunt field coil in a DC generator or motor is by connecting the field to a direct current source, at reduced field rated voltage, and test for ... placed near each field C. test lamp across adjacent fields D. copper jumper across the interpole connections

Last Answer : Answer: B

Description : Armature control of DC motor

Last Answer : Armature control of DC motor

Description : The speed-torque characteristics of a DC series motor are approximately similar to those of the _________motor. (A) universal (B) synchronous (C) DC shunt (D) two-phase

Last Answer : Ans: A Universal motor has same characteristics as DC series motor and also known as an a.c series motor.

Description : A 4 pole lap wound dc shunt motor rotates at the speed of 1500 rpm, has a flux of 0.4 mWb and the total number of conductors are 1000. What is the value of emf? (A) 100 Volts. (B) 0.1 Volts. (C) 1 Volts. (D) 10 Volts.

Last Answer : Ans: D Given N = 1500 rpm, Φ = 0.4 mWb, Z = 1000, P = 4, & A= 4 Therefore, Eb = NΦPZ / 60 A = 1500 x 0.4 x 4 x 1000 x 10^-3 / 60 x 4 = 60/6 = 10 volts

Description : A dc shunt generator has a speed of 800 rpm when delivering 20 A to the load at the terminal voltage of 220V. If the same machine is run as a motor it takes a line current of 20A from 220V supply. The speed of ... . (B) more than 800 rpm. (C) less than 800 rpm. (D) both higher or lower than 800 rpm.

Last Answer : (C) less than 800 rpm.

Description : Why does the speed of a DC shunt motor decrease as the load increases?

Last Answer : Because if the load is increasing then the torque must also be increase. If not then the speed of motor will decrease.

Description : An unsaturated dc shunt motor runs at its rated speed when rated voltage is applied to it. If the supply voltage to the motor is reduced by 25%, the speed of the motor  (a) Increases by 25% (b) Remains the same (c) Decreases by 25% (d) Decrease only slightly by an amount less than 25% 

Last Answer : An unsaturated dc shunt motor runs at its rated speed when rated voltage is applied to it. If the supply voltage to the motor is reduced by 25%, the speed of the motor Remains the same

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Description : An increase in the amount of current flow through the armature of a shunt motor is the final result of a/an _____________. A. increase in the load on the motor B. decrease in the load on the motor C. increase in counter EMF D. decrease in armature torque

Last Answer : Answer: A

Description : In the illustrated device, the part labeled '1A' _________. EL-0001 A. are start and run windings for a single phase shaded pole induction motor B. is the stator for a polyphase induction ... armature for a squirrel cage rotor motor D. are direct current shunt field windings for a universal motor

Last Answer : Answer: B

Description : In a series wound motor, the current passing through the field windings is also passing through the _____________. A. armature B. shunt field C. reactance comparator D. laminations

Last Answer : Answer: A

Description : A 220 V shunt motor develops a torque of 54 N-m at armature current of 10 A. The torque produced when the armature current is 20 A, is?

Last Answer : Armature torque, Ta=PØZIa/2πA So Ta1/Ta2=Ia1/Ia2 Ta2=Ta1*Ia2/Ia1        =54*20/10         =108

Last Answer : The armature torque of the D.C. shunt motor is proportional to armature current.

Last Answer : In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.

Description : What is the order of the characteristic equation of an armature controlled DC motor?  (A) First order equation (B) Second order equation (C) Zero order equation (D) Third order equation 

Last Answer : third order

Description : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be?

Last Answer : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be 580 V.

Description : A 220 V dc machine has an armature resistance o f 1-ohm. If the full load current is 20A, the difference in the induced voltage when the machine is running as a motor, and as a generator is

Last Answer : A 220 V dc machine has an armature resistance o f 1-ohm. If the full load current is 20A, the difference in the induced voltage when the machine is running as a motor, and as a generator is 40 V.

Description : In a potentiometer experiment the balancing with a cell is at length 240 cm. On shunting the cell with a resistance of `2Omega`, the balancing length

Last Answer : In a potentiometer experiment the balancing with a cell is at length 240 cm. On shunting the cell with a ... Omega` C. `4 Omega` D. `2 Omega`

Description : A transmitted signal 5 meters in wavelength is received by an antenna coil having a 50-Ω resistance and a 0.01 H inductance. What is the capacitance of the tuner shunting the antenna coil at this point? A. 0.704 fF B. 0.704 μF C. 0.704 nF D. 0.704 mF

Last Answer : A. 0.704 fF

Description : If a unloaded shunt motor's field were weakened by rheostat resistance or by an open circuit, the motor would _________. A. overspeed due to reduced CEMF B. stop because of low flux C. continue to run at base speed D. slow down and overheat

Last Answer : Answer: A

Description : The most efficient method of increasing the speed of a 3.75KW d.c. shunt motor would be  A) Armature control B) Flux control C) Ward—Leonard D) Tapped—field control

Last Answer :  Flux control 

Description : The basic type of D.C. motor speed control where a generator armature directly feeds the motor armature and the motor and generator fields are excited by a separate D.C. source is called ___________________. A. Burmeister-Wain B. Ward-Leonard C. Sperry-Rand D. Atlas-Copco

Last Answer : Answer: B