A true rms reading voltmeter uses two thermocouple in order: - 

a) to increase sensitivity b) that a second thermocouple cancels out the no linear effect of the first thermocouple c) to prevent drift in the dic. Amplifier d) all of the above

1 Answer

Answer :

A true rms reading voltmeter uses two thermocouple in order: -  that a second thermocouple cancels out the no linear effect of the first thermocouple

Related questions

Description : A digital voltmeter uses an A/D converter which needs a start pulse, uses an analog comparator and has a relatively fixed conversion time independent of the applied voltage. The A/D ... Successive Approximation Converter .b) Digital Ramp Converter c) Digital Slope Converter d) All the above

Last Answer : A digital voltmeter uses an A/D converter which needs a start pulse, uses an analog comparator and has a relatively fixed conversion time independent of the applied voltage. The A/D converter is : -  Successive Approximation Converter 

Description : Thermocouple instruments can be used for a frequency range upto   (a) 100Hz (b) 5000 Hz (c) 1 MHz (d) 50 MHz and above 

Last Answer : Thermocouple instruments can be used for a frequency range upto 50 MHz and above 

Description : Thermocouple is used to measure : - a) AC b) DC c) Both d) None

Last Answer : Thermocouple is used to measure : - a) AC b) DC c) Both d) None

Description : Conversion of heat into electrical er is achieved by using – (1) Ammeter (2) Hydrometer (3) Voltmeter (4) Thermocouple

Last Answer : (4) Thermocouple Explanation: Thermoelectric generators convert thermal energy into electricity by using heat from the body - or any object with a temperature gradient - as their energy source. ... energy into electricity. Bismuth telluride and its alloys are commonly used in thermocouples.

Description : Conversion of heat into electrical er is achieved by using : (1) Ammeter (2) Hydrometer (3) Voltmeter (4) Thermocouple

Last Answer : Thermocouple

Description : What does the Voltmeter in AC mode show? Is it RMS value or peak value?

Last Answer : Multimeter in AC mode shows RMS value of the voltage or current. Also when it is DC mode it will show the RMS value only.

Description : In a single phase induction energy meter, in order to obtain true value of energy, the shunt magnetic flux should lag behind the applied voltage by   (a) 90o (b) 0o (c) 45o (d) 60o

Last Answer : In a single phase induction energy meter, in order to obtain true value of energy, the shunt magnetic flux should lag behind the applied voltage by 90o

Description : In the illustrated motor controller, the motor fails to start. A voltmeter reading between 1 and 6 reads line voltage, while the voltmeter reading between 2 and 6 reads 0 VAC. The problem is __________. EL- ... in the 'M' coil, 'Ma' contact/start switch or overload contacts D. fuse '10a' is blown

Last Answer : Answer: B

Description : A current carrying conductor making an electrical contact with a wiring metal conduit is indicated by a _____________. A. low switchboard wattmeter reading B. reading of 1.0 on the power factor meter C. high switchboard voltmeter reading D. totally darkened switchboard ground-detecting light

Last Answer : Answer: D

Description : A multimeter may be damaged by taking a _____________. A. voltage reading while in the ammeter mode B. current reading while in the voltmeter mode C. resistance reading while in the ammeter mode D. resistance reading while in the voltmeter mode

Last Answer : Answer: A

Description : If the motor fails to start and a voltmeter reading between 1 and 6, as illustrated, indicates line voltage, your next step should be to ________. EL-0007 A. replace fuse '10a' B. replace or repair contact 'Ma' C. reset and determine the cause of the overload D. check line voltage between L1 and L3

Last Answer : Answer: C

Description : A low voltage source is being used for testing armature coils. A coil short circuit will be indicated by a _______. A. high voltage reading, while the other coil readings will have an ... the other coil readings are steady D. steady voltmeter reading, while the other coil readings are fluctuating

Last Answer : Answer: B

Description : If the Earth's magnetic field lines pass through the Hall probe in opposite direction, then the change in reading of voltmeter is A. thrice the Earth's magnetic flux density B. four times the Earth ... C. five times the Earth's magnetic flux density D. twice the Earth's magnetic flux density

Last Answer : twice the Earth's magnetic flux density

Description : High sensitive DC voltmeter provides accurate reading when measuring ___ circuits.

Last Answer : high resistance

Description : High sensitive DC voltmeter provides accurate reading when measuring ___ circuits.

Last Answer : high resistance

Description : A digital voltmeter has a read-out range from 0 to 9999 counts. When full scale reading is 9.999 V, the resolution of the instrument will be (a) 100 mV (b) 99 mV (c) 9 mV (d) 1 mV 

Last Answer : d) 1mV 9.999v÷9999v

Description :  In the case of an instrument reading of 8.3 V with a 0 to 150 voltmeter having a guaranteed accuracy of 1% full scale reading, the percentage limiting error is   (A) 1.810% (B) 0.181% (C)12.45% (D) 0.0018%

Last Answer :  In the case of an instrument reading of 8.3 V with a 0 to 150 voltmeter having a guaranteed accuracy of 1% full scale reading, the percentage limiting error is 12.45%

Description : Which one of the following is not a transducer in the true sense?   (A) Thermocouple (B) Piezoelectric pick-up (C) Photo voltaic cell (D) LCD.

Last Answer : Which one of the following is not a transducer in the true sense?   (A) Thermocouple (B) Piezoelectric pick-up (C) Photo voltaic cell (D) LCD.

Description : Which of the following meters uses a shunt connected in series with the load, but parallel with the meter movement? A. voltmeter B. power factor meter C. wattmeter D. ammeter

Last Answer : Answer: D

Description : Which of the listed meters uses a shunt connected in series with the load, but parallel with the meter movement? A. Voltmeter B. Power factor meter C. Ammeter D. Wattmeter

Last Answer : Answer: C

Description : A Kelvin electrostatic voltmeter uses what method of damping?

Last Answer : fluid friction

Description : Mark correct option related to preservation period a) Order book of mail office and section is three years b) Work paper of RMS offices and section is eighteen months c) Correspondence related to robberies, theft etc is one year after the case closed. d) All the above are correct

Last Answer : d) All the above are correct

Description : The Postmaster or_______personal duties prescribed in this rule may, under the order of_________, be delegated to the _________, Assistant Postmaster, Supervisor or office supervisor of the _______ as ... Deputy postmaster, office d) Record officer , Head of the Circle, Deputy postmaster, office

Last Answer : a) Head Sorting Assistant , Head of the Circle, Deputy postmaster, office

Description : In order to increase its range of measurement, a resistance would be placed in series with which of the following instruments? A. DC voltmeter B. DC ammeter C. frequency meter D. power factor meter

Last Answer : Answer: A

Description : In order to check the performance of a transistor removed from its circuit, the instrument to be used should be a/an ____________. A. voltmeter or transistor tester B. impedance meter C. ohmmeter or transistor tester D. sensitive potentiometer

Last Answer : Answer: C

Description : In order to make an accurate measurement as possible, the internal resistance of a voltmeter must be

Last Answer : as high as possible

Description : In order to increase the range of a voltmeter

Last Answer : In order to increase the range of a voltmeter a high resistance is connected in series

Last Answer : The internal resistance of the voltmeter must be very high in order to have Minimum current through the meter.

Description : state properties that makes thermocouple very sensitive?

Last Answer : it measures temperatures between -250 and 1600 degree and it can measure a wider range of temperatures

Description : What is Thermocouple ?

Last Answer : : Thermocouple is a metalic bar that can be used to measure the temperature of a place. Thermocouple is an analog sensor. It is used to measure temperature. In thermocouples thermo or tharmal means ... has two terminals, one positive and the other negative. It is measured in meter voltage mode.

Description : Thermocouple How It is Work By ?

Last Answer : Thermocouple A metalic bar , whose With the help No Of space Temperature Measurement To do Goes Thermocouple a _ Analog Sensor This is it Temperature Measurement To do At work Use Is . ???? ... _ Two Terminal Stays A Positive And The other Negative. This Meters Voltage Mode To measure Is.

Description : What is the energy conversion for a thermocouple?

Last Answer : A thermocouple uses the thermoelectric effect to do what it does. Thermal energy (heat) is converted into a difference of potential, which is electric (electromagnetic) energy.

Description : The instrument used to regulate temperature to a particular degree is called : (1) Thermostat (2) Thermometer (3) Pyrometer (4) Thermocouple

Last Answer : (1) Thermostat Explanation: A thermostat is a component which senses the temperature of a system so that the system's temperature is maintained near a desired set point. At its core, a thermostat is simply the controls used to regulate temperature in a heating system.

Description : The sensor connected to 'signal conditioner' (6000F125) shown in the illustration is a/an ______________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: B

Description : The sensor connected to 'signal conditioner' (6000AH170) shown in the illustration is a/an _____________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: A

Description : The sensor connected to 'signal conditioner' (6000F085) shown in the illustration is a/an ______________. EL-0094 A. thermocouple B. transducer C. inverter D. RTD

Last Answer : Answer: D

Description : Which sensor shown in the illustration develops its own conditioning and point setting and 'reports' directly to the 'annunciator'? EL-0094 A. Transducer B. Resistance Temperature Detector (RTD) C. Pressure Switch D. Thermocouple

Last Answer : Answer: C

Description : Which of the following devices should be used to measure the temperature of a battery electrolyte? A. Mercury thermometer B. Alcohol thermometer C. Thermocouple pyrometer D. Potentiometer

Last Answer : Answer: B

Description : Thermocouple is suitable for measuring (A) Liquid temperatures only (B) Very high temperatures only (C) Very low temperatures only (D) Both high and low temperatures

Last Answer : (D) Both high and low temperatures

Description : When a bare thermocouple is covered by a protective sheath, the response becomes (A) Faster and oscillatory (B) Faster and non-oscillatory (C) Slower and oscillatory (D) Slower and non-oscillatory

Last Answer : (D) Slower and non-oscillatory

Description : An alloy used as thermocouple material comprises of 40% nickel and60% copper. It is called (A) Constantan (B) Kanthal (C) Chromel (D) German silver

Last Answer : (A) Constantan

Description : What is the equation for resistance measurement of PT 100 thermocouple? 

Last Answer : °C = (R-100) / 0.39  

Description : State some thermocouple. 

Last Answer : Copper – constantan, Iron – constantan.  

Description : The following thermocouple may be used for measuring temperature upto 1873°K. (A) Chromel-alumel (B) Copper-constantan (C) Platinum-platinum rhodium (D) Iron-constantan

Last Answer : (C) Platinum-platinum rhodium

Description : Temperature of hot gases flowing in a pipe is measured by a thermocouple inserted in the thermal well. The thermal well made of __________ will facilitate the most accurate measurement of the temperature. (A) Copper (B) Steel (C) Aluminium (D) Brass

Last Answer : Option A

Description : Temperature of hot gases flowing in a pipe is measured by a thermocouple inserted in the thermal well. The thermal well made of __________ will facilitate the most accurate measurement of the temperature. (A) Copper (B) Steel (C) Aluminium (D) Brass

Last Answer : Option A

Description : Pressure is measured with the help of A. Manometer. C) Thermocouple. B. Ammeter. D) Orifice plate.

Last Answer : manometer

Description : What device measures infrared radiation below?  a. thermocouple  b. thermopile  c. thermodynamic device  d. thermos

Last Answer : thermopile

Description : Thermocouple is used to measure a) AC b) DC c) Both d) None

Last Answer : Ans: Both