The number of parallel paths in the armature winding of a 4 -pole, wave connected d.c. machine having 28 coilside is : - 

a) 28 b) 14 c) 4 d) 2

2 Answers

Answer :

 The number of parallel paths in the armature winding of a 4 -pole, wave connected d.c. machine having 28 coilside is : - 2

Answer :

2

Related questions

Description : The number of parallel paths in armature winding of four pole wave winding connected dc machine having 22 coil sides is (1) 4 (2) 22 (3) 2 (4) 11 

Last Answer : Ans- Option (3) because wave winding always have 2 parallel paths

Description : Which one of the following statements for a dc machine which is provided with inter pole winding (IW) as well as compensating winding (CW) is correct a) Both IW and CW are connected in ... parallel with Armature winding d) CW connected in series but IW is connected in parallel with Armature winding

Last Answer : Ans: Both IW and CW are connected in series with Armature winding

Description : In a 4-pole wave winding connected dc motor, the cross-magnetizing AT/pole for a brush shift of θ radians (A) Armature amp-conductors × (θ/360o) (B) Armature amp-turns × (θ/360o) (C) Armature amp-conductors × (1/4 - θ/360o) (D) Armature amp-conductors × (1/8 - θ/360o)

Last Answer : In a 4-pole wave winding connected dc motor, the cross-magnetizing AT/pole for a brush shift of θ radians Armature amp-conductors × (1/8 - θ/360o)

Last Answer : In series with the shunt winding

Description : To carry out an insulation resistance test, one terminal of the megohmmeter should be connected to the winding, with the other terminal being connected to the ____________________. A. power supply B. variable resistor C. frame of the machine D. armature

Last Answer : Answer: C

Description : Which of the following types of DC motors has its field connected in parallel with its armature? A. Counter EMF B. Shunt C. Salient pole D. Series

Last Answer : Answer: B

Description : In DC generators, armature reaction is produced actually by (A) Its field current. (B) Armature conductors. (C) Field pole winding. (D) Load current in armature.

Last Answer : Ans: D Because load current in armature gives rise to armature mmf which react with main field mmf.

Description : Before testing insulation with a megohmmeter, the windings of large machines should be grounded for about 15 minutes just prior to the test, because the ___________. A. static charge of the machine ... number of leakage paths C. insulation may be damaged D. insulation may be covered with moisture

Last Answer : Answer: A

Description : The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is  (1) 1000V (2) 100V (3) 600V (4) 10,000V

Last Answer : The induced emf in the armature of a lap -wound four -pole dc machine having 100 armature conductors rotating at 600 rpm and with 1 Wb flux per pole is 1000V

Description : Aluminium is not used as winding wire for the armature of a dc machine because  (1) aluminium has low resistivity (2) a large winding space is taken by aluminium conductors and creates ... ) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Last Answer : Aluminium is not used as winding wire for the armature of a dc machine because  (2) a large winding space is taken by aluminium conductors and creates jointing problems (3) the thermal conductivity of aluminium is low (4) aluminium has low conductivity as compared to copper

Description : A 8-pole, DC generator has a simplex wave-wound armature containing 32 coils of 6 turns each. Its flux per pole is 0.06 Wb. The machine is running at 250 rpm. The induced armature voltage is  (A) 96 V (B) 192 V (C) 384 V (D) 768 V

Last Answer : A 8-pole, DC generator has a simplex wave-wound armature containing 32 coils of 6 turns each. Its flux per pole is 0.06 Wb. The machine is running at 250 rpm. The induced armature voltage is 384 V

Description : Before testing insulation with a megohmmeter, the windings of large machines should be grounded for about 15 minutes just prior to the test as the ______________. A. insulation may be damaged ... number of leakage paths D. larger machines may acquire a charge of static electricity during operation

Last Answer : Answer: D

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Last Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Description : A 4-pole, 3-phase, double-layer winding is housed in a 36-slot stator for an ac machine with 60o phase spread. Coil span is 7 short pitches. Number of slots in which top and bottom layers belong to different phases is  (A) 24 (B) 18 (C) 12 (D) 0

Last Answer : A 4-pole, 3-phase, double-layer winding is housed in a 36-slot stator for an ac machine with 60o phase spread. Coil span is 7 short pitches. Number of slots in which top and bottom layers belong to different phases is 24 

Description : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively

Last Answer : A 36 slot, 4 -pole, dc machine has a simplex lap winding with two conductors per slot. The back pitch and front pitch adopted could be respectively 19,17

Last Answer : It is the wire wound around a aluminium metal it is found commonly in transformers or motors

Description : State the function of armature winding and name the material used for its construction.

Last Answer : The function of armature winding: The armature conductors are connected in systematic manner to from armature winding. It is used to circulate armature current (load current) when DC machine gets ... construction:  The armature winding is made up of super insulated copper or aluminum wire.

Description : 27] In a transformer, the leakage flux of each winding is proportional to the current in that winding because A. Ohm's law applies to magnetic circuits B. Leakage paths do no saturate C. the two windings are electrically isolated D. mutual flux is confined to the core

Last Answer : B. Leakage path do not saturate

Description : A DC shunt generator has its field windings connected in _____________. A. series with the series windings B. parallel with the field rheostat C. series with the armature windings D. parallel with the armature windings

Last Answer : Answer: D

Description : Number of commutator bars for a 4-pole, 2-layer, DC lap winding with 24 slots and one conductor per layer is (A) 48 (B) 24 (C) 192 (D) 96

Last Answer : Number of commutator bars for a 4-pole, 2-layer, DC lap winding with 24 slots and one conductor per layer is 24

Description : In a capacitor start single-phase induction motor, the capacitor is connected (A) in series with main winding. (B) in series with auxiliary winding. (C) in series with both the windings. (D) in parallel with auxiliary winding.

Last Answer : Ans: B To make single phase motor self start. We split the phases at 90 degree. Hence, motor behaves like a two phase motor.

Description : Which of the following losses is/are present in every direct current generator armature? A. Winding copper loss B. Core eddy current loss C. Magnetic hysteresis loss D. All of the above.

Last Answer : Answer: D

Description : Three factors responsible for the change in voltage as load is applied to an AC generator are: 1) the drop in resistance in the armature circuit, 2) the change in flux, and 3) the ____________. A. armature winding speed B. inductance load drop C. coil pitch factor D. armature reactance voltage drop

Last Answer : Answer: D

Description : Which of the following statements is true concerning all three-phase alternators? A. Each has three separate but identical armature windings acted on by one system of rotating magnets. B. Each has one ... The three phases always provide power to the load through three sets of slip rings and brushes.

Last Answer : Answer: A

Description : Which type of winding is preferred for armature windings of alternator? Why?

Last Answer : Double layer, short pitched and distributed type of armature winding. It eliminates high frequency harmonics hence it makes induced emf more sinusoidal.

Description : cooling is the process of dissipating the armature and field winding losses to a cooling medium circulating within the winding insulation wall (a) Direct (b) Indirect (c) Conventional (d) Any ofthe above

Last Answer : (a) Direct

Description : For a DC motor, what major component in addition to the field winding and the armature winding is necessary? w) a commutator x) a stator y) a battery z) a rotor

Last Answer : ANSWER: W -- A COMMUTATOR

Description : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is

Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Last Answer : The resistance of armature winding depends on length of conductor, cross-sectional area of the conductor, number of conductors.

Description : Brushes in a generator must be positioned in the neutral plane to avoid sparking between the brushes and the _____________. A. yoke B. armature windings C. field pole windings D. commutator

Last Answer : Answer: D

Description : If a DC motor runs faster than designed, with all other conditions being normal, the possible cause could be a/an ______________. A. shorted shunt field coil B. open armature coil C. reversed commutating pole D. overload

Last Answer : Answer: A

Description : Which of the listed conditions will occur if the polarity of the field poles and the direction of current to the brushes of a DC motor were both reversed? A. The motor would not start. ... direction of rotation of the armature would be unchanged. D. The field pole windings would become overheated.

Last Answer : Answer: C

Description : In the illustrated device, the part labeled '1A' _________. EL-0001 A. are start and run windings for a single phase shaded pole induction motor B. is the stator for a polyphase induction ... armature for a squirrel cage rotor motor D. are direct current shunt field windings for a universal motor

Last Answer : Answer: B

Description : Which of the following statements describes what will happen when both the polarity of the field poles, and the direction of current to the brushes of a DC motor are reversed? A. The motor will ... of rotation of the armature will remain the same. D. The field pole windings will become overheated.

Last Answer : Answer: C

Description : Why The Air Gap Between The Pole Pieces And The Armature Is Kept Very Small?

Last Answer : The air gap between the pole pieces and the armature is kept very small to keep the field strength at its highest value. This is due to the reason the flux lines can pass through iron very ... must be the magnetizing force to produce the required voltage hence the air gap is kept very small.

Description : The introduction of interpoles in between the main pole improves the performance of d.c. machines, because (A) The interpole produces additional flux to augment the developed torque. (B) The flux waveform is ... armature is removed. (D) A counter e.m.f. is induced in the coil undergoing commutation.

Last Answer : Ans: D Counter e.m.f is produced, it neutralizes the reactive emf.

Description : Which of the following methods may be adopted to reduce the effects of armature reaction ? (a) Increase in length of air gap at pole tips (b) Increasing reluctance of pole tips (c) Compensating windings (d) Interpoles (e) All of the above

Last Answer : (e) All of the above

Description : Find condition is true for food web a) A food web only follows just one path c) A food web starts with a consumer b) A food web ends with a producer d) A food web shoes many paths plants and animals connected

Last Answer : A food web shoes many paths plants and animals connected

Description : A 1100 kVA, 11 kV/1.1 kV conventional two-winding transformer is connected as a 12.1 kV/11 kV step-down auto-transformer. The rating of the auto-transformer is (A) 1000 kVA (B) 1100 kVA (C) 11000 kVA (D) 12100 kVA

Last Answer : A 1100 kVA, 11 kV/1.1 kV conventional two-winding transformer is connected as a 12.1 kV/11 kV step-down auto-transformer. The rating of the auto-transformer is 12100 kVA

Description : Why shaded-pole single phase induction motor does not need any special starting technique like capacitors and auxiliary winding etc.

Last Answer : Because it is inherently self started motor. The construction of the poles is such that they give a sweep to the magnetic flux and motor starts rotating.

Last Answer : In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be 8.

Last Answer : If the field winding of an unloaded salient pole synchronous motor is open circuited, the motor will stop.

Description : What are the paths of a parallel circuit?

Last Answer : There are more than one path for a parallel circuit

Last Answer : The number of conductors of the compensating winding in a D.C. machine is always less than the number of armature conductors per pole.

Last Answer : Functions of armature core: 1) Support the armature winding which is placed in its slots. 2) Rotate as driven by the prime mover (generator) or as per the torque produced (motor).  Hence ... magnetic path to increase the magnitude of induced emf for a certain MMF created by the field winding. 

Description : Which of the following quantity maintains the same direction whether a D.C. machine runs as a generator or as a motor a. Induced e.m.f. b. Armature Current c. Field Current d. Supply Current  

Last Answer : Which of the following quantity maintains the same direction whether a D.C. machine runs as a generator or as a motor a. Induced e.m.f. b. Armature Current c. Field Current d. Supply Current  

Description : A 220 V dc machine has an armature resistance o f 1-ohm. If the full load current is 20A, the difference in the induced voltage when the machine is running as a motor, and as a generator is

Last Answer : A 220 V dc machine has an armature resistance o f 1-ohm. If the full load current is 20A, the difference in the induced voltage when the machine is running as a motor, and as a generator is 40 V.

Description : Two transformers having the same p.u. impedance connected in parallel share the connected load (A) equally (B) in proportion to the respective ratings (C) in proportion to the voltage ratio (D) in proportion to the zero phase displacement

Last Answer : Two transformers having the same p.u. impedance connected in parallel share the connected load in proportion to the respective ratings

Description : What is the equivalent resistance of a network having 5 resistors of each 10ohm connected in parallel?  (A) 10 Ohms (B) 50 Ohms (C) 500 Ohms (D) 2 Ohms 