DC Generator: A dc generator is an electrical machine which converts mechanical energy into direct current electricity. This energy conversion is based on the principle of production of dynamically induced emf. This article outlines basic construction and working of a DC generator.


Construction of a DC generator:  A DC generator can be used as a DC motor without any constructional changes and vice versa is also possible. Thus, a DC generator or a DC motor can be broadly termed as a DC machine. These basic constructional details are also valid for the construction of a DC motor. Hence, let's call this point as construction of a DC machine instead of just 'construction of a dc generator'.

image

The above figure shows the constructional details of a simple 4-pole DC machine. A DC machine consists two basic parts; stator and rotor. Basic constructional parts of a DC machine are described below.

1. Yoke: The outer frame of a dc machine is called as yoke. It is made up of cast iron or steel. It not only provides mechanical strength to the whole assembly but also carries the magnetic flux produced by the field winding. 

2. Poles and pole shoes: Poles are joined to the yoke with the help of bolts or welding. They carry field winding and pole shoes are fastened to them. Pole shoes serve two purposes; (i) they support field coils and (ii) spread out the flux in air gap uniformly. 

3. Field winding: They are usually made of copper. Field coils are former wound and placed on each pole and are connected in series. They are wound in such a way that, when energized, they form alternate North and South poles. 

4. Armature core: Armature core is the rotor of the machine. It is cylindrical in shape with slots to carry armature winding. The armature is built up of thin laminated circular steel disks for reducing eddy current losses. It may be provided with air ducts for the axial air flow for cooling purposes. Armature is keyed to the shaft. 

5. Armature winding: It is usually a former wound copper coil which rests in armature slots. The armature conductors are insulated from each other and also from the armature core. Armature winding can be wound by one of the two methods; lap winding or wave winding. Double layer lap or wave windings are generally used. A double layer winding means that each armature slot will carry two different coils. 

6. Commutator and brushes: Physical connection to the armature winding is made through a commutator-brush arrangement. The function of a commutator, in a dc generator, is to collect the current generated in armature conductors. Whereas, in case of a dc motor, commutator helps in providing current to the armature conductors. A commutator consists of a set of copper segments which are insulated from each other. The number of segments is equal to the number of armature coils. Each segment is connected to an armature coil and the commutator is keyed to the shaft. Brushes are usually made from carbon or graphite. They rest on commutator segments and slide on the segments when the commutator rotates keeping the physical contact to collect or supply the current.


Working principle of a DC generator:  According to Faraday’s laws of electromagnetic induction, whenever a conductor is placed in a varying magnetic field (OR a conductor is moved in a magnetic field), an emf (electromotive force) gets induced in the conductor.  The magnitude of induced emf can be calculated from the emf equation of dc generator. If the conductor is provided with the closed path, the induced current will circulate within the path.  In a DC generator, field coils produce an electromagnetic field and the armature conductors are rotated into the field. Thus, an electromagnetically induced emf is generated in the armature conductors. The direction of induced current is given by Fleming’s right hand rule.  according to Fleming’s right hand rule, the direction of induced current changes whenever the direction of motion of the conductor changes. Let’s consider an armature rotating clockwise and a conductor at the left is moving upward.  When the armature completes a half rotation, the direction of motion of that particular conductor will be reversed to downward.  Hence, the direction of current in every armature conductor will be alternating. If you look at the a figure, you will know how the direction of the induced current is alternating in an armature conductor 

image

.But with a split ring commutator, connection s of the armature conductors also gets reversed when the current reversal occurs. And therefore, we get unidirectional current at the terminals.


0 like 0 dislike
Next Question ⇨⇦ Previous Question

Related questions

With a neat circuit diagram Explain the construction and principle of operation of DC Motor.
Last Answer : DC MOTOR - INTRODUCTION:  A machine that converts dc power into mechanical energy is known as dc motor. Its operation is based on the principle that when a current carrying conductor is placed in a ... , an upward force will move one wire up and a downward force will move the other wire down. ...

Show More
0 like 0 dislike
1 answer

Random Images

Explain the working principle of various types of single phase induction motor with neat circuit diagram.
Last Answer : The single phase induction motors are made self- starting by providing an additional flux by some additional means. Now depending upon these additional means the single phase induction motors are classified as ... maximum value. 3. When the flux decreases from maximum positive value to zero. ...

Show More
0 like 0 dislike
1 answer

Random Images

Explain the different types of dc motor with neat sketch.
Last Answer :  DC MOTOR TYPES  Shunt Wound  Series Wound  Compound wound 1. Shunt Motor  In shunt wound motor the field winding is connected in parallel with armature. ... that it shunts the series combination of armature and series field it is called long-shunt connection. ...

Show More
0 like 0 dislike
1 answer

Random Images

Describe various types self -excited of DC generator with their circuit layout.
Last Answer : DC generators are classified based on their method of excitation. So on this basis there are two types of DC generators:- Self-excited DC generator can again be classified as 1) DC Series generator 2) DC ... (Rse is wired in series to the armature). It is shown in figure (2)   ...

Show More
0 like 0 dislike
1 answer

Random Images

Explain the construction, working principle of single phase Induction motor.
Last Answer : Single phase motors are very widely used in home, offices, workshops etc. as power delivered to most of the houses and offices is single phase. In addition to this, single phase motors are ... rated speed. This behavior of a single phase motor can be explained by double-field revolving theory. ...

Show More