Request Answer
Why use the VCB at High Transmission System? Why can’t use ACB? 
0 like 0 dislike

Please log in or register to answer this question.

1 Answer

Actually the thing is vacuum has high arc quenching property compare to air because in VCB, the die electric strengths equal to 8 times of air. That y always vacuum used as in HT breaker and air used as in LT.
0 like 0 dislike
Next Question ⇨⇦ Previous Question

Related questions

Why is the starting current high in a DC motor?
Last Answer : In DC motors, Voltage equation is V=Eb-IaRa (V = Terminal voltage, Eb = Back emf in Motor, Ia = Armature current, Ra = Armature resistance).At starting, Eb is zero. Therefore, V=IaRa, Ia = V/Ra ,where Ra is very less like 0.01ohm.i.e, Ia will become enormously increased. ...

Show More
0 like 0 dislike
1 answer

Random Images

Why do we use the starter for a DC motor?
Last Answer : Large DC motors with field windings instead of permanent magnets have a very heavy load when starting. To prevent fuses from blowing, a series of small resistors are sequentially switched in series with the ... current. When the motor reaches its running speed, the starter' is out of the circuit...

Show More
0 like 0 dislike
1 answer

Random Images

Why Negative Feedback is preferred in the Control System? 
Last Answer : The role of Feedback in control system is to take the sampled output back to the input and compare output signal with input signal for error (deviation from the desired result). Negative ... and is less sensitive to the parameter variations. Hence in control systems negative feedback is considered....

Show More
0 like 0 dislike
1 answer

Random Images

Why ELCB can't work if N input of ELCB do not connect to ground?
Last Answer : ELCB is used to detect earth leakage fault. Once the phase and neutral are connected in an ELCB, the current will flow through phase and that much current will have to return neutral so resultant ... that full fault current will come back through ELCB, and there will be no difference in current....

Show More
0 like 0 dislike
1 answer

Random Images

Why, when birds sit on transmission lines or current wires doesn’t get shock? 
Last Answer : It's true that if birds touch the single one line (phase or neutral) they don't get electrical shock if birds touch 2 lines than the circuit is closed and they get electrical shock. so if a ... is grounded. So that means that human who touch the line closes the circuit between phase and neutral. ...

Show More
0 like 0 dislike
1 answer