Description : What type of processor does the alienware m15x have?

Last Answer : http://www.laptopmag.com/review/laptops/alienware-m15x.aspx?mode=specs

Description : State the material used for making (1) Magnetic Core (2) Fuse element  

Last Answer : The material used for making of:  (1) Magnetic Core : Iron, cobalt, Nickel, CRGO, HRGO , silicon steel  (2) Fuse Element: Tin- lead wire, Tinned copper wire 

Description : State any four characteristics of core type transformer.

Last Answer : Characteristics of core type transformer: i) It has one window. ii) It has one magnetic circuit. iii) Core surrounds the winding. iv) Average length of core is more. v) Area of cross ... Better cooling for winding. vii) Mechnical strength is comparatively less. viii) Repair and maintenance is easy.

Description : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is

Last Answer : A 40 kVA transformer has a core loss of 400 W and a full load copper loss of 800 W. The proportion of full load at maximum efficiency is 0.707

Description : The core construction is like spokes of a wheel in following transformer:  (A) Berry Type Transformer (B) Core Type Transformer (C) Shell Type Transformer (D) None of the above

Last Answer : The core construction is like spokes of a wheel in following transformer:  Berry Type Transformer

Description : Core type transformers are popular in___________.  (A) High voltage applications (B) Low voltage applications (C) All of the above (D) None of the above

Last Answer : Core type transformers are popular in High voltage applications

Description : The desirable properties of transformer core material are  (1) low permeability and low hysteresis loss. (2) high permeability and high hysteresis loss. (3) high permeability and low hysteresis loss. (4) low permeability and hysteresis loss.

Last Answer : The desirable properties of transformer core material are high permeability and low hysteresis loss.

Description : A single core lead sheathed cable with two dielectrics of permittivity 4 and 3, respectively, are subjected to same maximum stress. If the conductor diameter is 1.5 cm, the outer diameter of the first dielectric is (A) 1.125 cm (B) 1.5 cm (C ) 2 cm (D) 8 cm

Last Answer : A single core lead sheathed cable with two dielectrics of permittivity 4 and 3, respectively, are subjected to same maximum stress. If the conductor diameter is 1.5 cm, the outer diameter of the first dielectric is 2 cm 

Description : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is (A) 28.2 mm (B) 26.4 mm (C) 24.4 mm (D) 22.0 mm

Last Answer : A single core cable is designed to work for a single phase system with a peak voltage of 220 kV. The maximum permissible stress in the dielectric is not to exceed 20 kV/mm. For economical size, the overall core diameter of the cable is 22.0 mm

Description : The main purpose of using core in a transformer is to (A) decrease iron losses (B) eliminate magnetic hysteresis (C) reduce reluctance of the common magnetic circuit (D) prevent eddy current loss

Last Answer : Reduce Relucatnce of the common magnetic circuit.

Description : A ferrite core has less eddy current loss than an iron core because?

Last Answer : A ferrite core has less eddy current loss than an iron core because ferrites have high hysteresis.

Last Answer : The armature core of a D.C. generator is usually made of silicon steel.

Last Answer : When a conductor carries more current on the surface as compared to core, it is due to skin effect.

Last Answer : Material used for construction of transformer core is usually silicon steel.

Description : When secondary of a current transformer is open-circuited its iron core will be?

Last Answer : When secondary of a current transformer is open-circuited its iron core will be hot because of heavy iron losses taking place in it due to high flux density.

Description : The size of a transformer core will depend on?

Last Answer : The size of a transformer core will depend on frequency and area of the core.

Description : Reduction in core losses and increase in permeability are obtained with transformer employing?

Last Answer : Reduction in core losses and increase in permeability are obtained with transformer employing core built-up of laminations of cold rolled grain oriented steel.

Description : Why does the core of a transformer need to be laminated?

Last Answer : Transformer cores are laminated to reduce eddy current loss.

Description : In DC generators lamination core are generally made of?

Last Answer : In DC generators lamination core are generally made of silicon steel.

Last Answer : Transformer core is laminated to reduce Eddy current losses.