The corona loss in a 50 Hz system is 0.25 kW/ph/km. At a frequency of 60 Hz, the corona loss would be 

 (a) 0.30 kW/ph/km (b) 0.36 kW/ph/km (c) 028 kW/ph/km (d) 0.21 kW/ph/km

1 Answer

Answer :

The corona loss in a 50 Hz system is 0.25 kW/ph/km. At a frequency of 60 Hz, the corona loss would be 028 kW/ph/km

Related questions

Description : The corona loss on a particular system at 50 Hz is 1 kw/phase per km. The corona loss on the same system with supply frequency 25 Hz will be?

Last Answer : The corona loss on a particular system at 50 Hz is 1 kw/phase per km. The corona loss on the same system with supply frequency 25 Hz will be 0.667 kW/phase/km.

Description : The corona loss of a 3-phase transmission line is 100 kW at 60 kV/phase and 25 kW at 50 kV/phase. The disruptive critical voltage is (A) 40 kV (B) 43.6 kV (C) 49.6 kV (D) 50 kV

Last Answer : The corona loss of a 3-phase transmission line is 100 kW at 60 kV/phase and 25 kW at 50 kV/phase. The disruptive critical voltage is 40 kV

Description : A 3-phase, 11 kv, 50 Hz, 200 kW load has a power factor of 0.8 lag. A delta connected 3-phase capacitor is used to improve the power factor to unity. The capacitance perphase of the capacitor in micro-farads is?

Last Answer : A 3-phase, 11 kv, 50 Hz, 200 kW load has a power factor of 0.8 lag. A delta connected 3-phase capacitor is used to improve the power factor to unity. The capacitance perphase of the capacitor in micro-farads is 1.316.

Description : For a 500 Hz frequency excitation, a 50 km long power line will be modeled as

Last Answer : For a 500 Hz frequency excitation, a 50 km long power line will be modeled as long line

Description : A 60 Hz, 320 km lossless line has Bending end voltage 1.0 p.u, The receiving end voltage on no load is?

Last Answer : A 60 Hz, 320 km lossless line has Bending end voltage 1.0 p.u, The receiving end voltage on no load is 1.088 p.u.

Description : Grid cables are 15 km long with a resistance of 0.20 Ω km-1, powers wasted as heat in these cables are A. 50 kW B. 60 kW C. 20 kW D. 30 kW

Last Answer : 30 kW

Description : If transformer frequency is changed from 60 Hz, to 60 Hz the ratio of eddy current loss 60 Hz to 50 Hz, at constant voltage will be?

Last Answer : If transformer frequency is changed from 60 Hz, to 60 Hz the ratio of eddy current loss 60 Hz to 50 Hz, at constant voltage will be 1.0.

Description : Corona loss in transmission lines can be reduced by (A) using small diameter conductors (B) using bundled conductors (C) using less spacing between conductors (D) increasing the transmission line voltage

Last Answer : Corona loss in transmission lines can be reduced by using bundled conductors

Description : Corona loss can be reduced by the use of hollow conductors because?

Last Answer : Corona loss can be reduced by the use of hollow conductors because of better ventilation in the conductor.

Description : A 50 Hz, 4-pole, 500 MVA, 22 kV turbo-generator is delivering rated megavolt amperes at 0.8 power factor. Suddenly a fault occurs reducing in electric power output by 40%. Neglect losses and assume constant power input to the ... the time of fault will be  (A) 1.528 (B) 1.018 (C) 0.848 (D) 0.509

Last Answer : A 50 Hz, 4-pole, 500 MVA, 22 kV turbo-generator is delivering rated megavolt amperes at 0.8 power factor. Suddenly a fault occurs reducing in electric power output by 40%. Neglect losses and assume ... the shaft. The accelerating torque in the generator in MNm at the time of fault will be 1.018 

Description : Generators at a power station produce electric power at voltage A. 45 kW B. 50 kW C. 60 kW D. 25 kW

Last Answer : 25 kW

Description : A weight of 50 N is suspended from a spring of stiffness 4000N/m and subjected to a harmonic force of magnitude 60N and frequency 60 Hz. what will be the static displacement of the spring due to maximum applied force A. 0.015m B. 0.15 m C. 15 m D. 150m

Last Answer : B. 0.15 m

Description : A 3-phase, 400 votts, 50 Hz, 100 KW, 4 pole squirrel cage induction motor with a rated slip of 2% will have a rotor speed of (A) 1500 rpm (B) 1470 rpm (C) 1530 rpm (D) 1570 rpm

Last Answer : Ans: B N = NS (1-S) and NS =120 f / p =120 x 50 /4 = 1500 rpm ∴N= 1500 (1-0.02) =1470 rpm

Description : A three-phase, 440 V, 50 Hz ac mains fed thyristor bridge is feeding a 440 V dc, 15 kW, 1500 rpm separately excited dc motor with a ripple free continuous current in the dc link under all operating conditions, Neglecting the ... at half the rated speed is  (A) 0.354 (B) 0.372 (C) 0.90 (D) 0.955

Last Answer : A three-phase, 440 V, 50 Hz ac mains fed thyristor bridge is feeding a 440 V dc, 15 kW, 1500 rpm separately excited dc motor with a ripple free continuous current in the dc link under all operating conditions, Neglecting the losses, the power factor of the ac mains at half the rated speed is 0.354

Description : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is  (A) 1.66 Nm (B) 95.50 Nm (C) 99.47 Nm (D) 624.73 Nm

Last Answer : A 400 V, 15 kW, 4-pole, 50 Hz, Y-connected induction motor has full load slip of 4%. The output torque of the machine at full load is 99.47 Nm

Description : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor ... Hz supply is  (A) 58.5 A (B) 45.0 A (C) 42.7 A (D) 55.6 A

Last Answer : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is 45.0 A 

Description : A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is

Last Answer : A 50 Hz, 4 pole turboalternator rated at 20 MVA. 13.2 KV has an inertia constant H = 4 KW sec/KVA. The K.E. stored in the rotor at synchronous speed is 80 MJ

Description : A 3 phase, 400 volts, 50 Hz, 100 kW, 4 pole squirrel cage induction motor with a rated slip of 2% will have a rotor speed of: (A) 1500 rpm (B) 1470 rpm (C) 1530 rpm (D) 1570 rpm

Last Answer : 1470rpm

Description : Over taking time required for a vehicle with design speed 50 km ph and overtaking acceleration 1.25 m/sec2 to overtake a vehicle moving at a speed 30 km ph, is (A) 5.0 secs (B) 6.12 secs (C) 225.48 secs (D) 30 secs

Last Answer : Answer: Option B

Description : A district road with a bituminous pavement has a horizontal curve of 1000 m for a design speed of 75 km ph. The super-elevation is (A) 1 in 40 (B) 1 in 50 (C) 1 in 60 (D) 1 in 70

Last Answer : Answer: Option A

Description : The low voltage winding of a 400/230 V, 1-phase, 50 Hz transformer is to be connected to a 25 Hz, the supply voltage should be

Last Answer : The low voltage winding of a 400/230 V, 1-phase, 50 Hz transformer is to be connected to a 25 Hz, the supply voltage should be 115 V.

Description : A two conductor 1 - pi line operates at 50 Hz.The diameter of each conductor is 20 mm and the spacing between the conductors is 3m, The height of conductor above the ground is 6 m. The capacitance of the line to neutral will be?

Last Answer : A two conductor 1 - pi line operates at 50 Hz. The diameter of each conductor is 20 mm and the spacing between the conductors is 3m, The height of conductor above the ground is 6 m. The capacitance of the line to neutral will be 9.7 pF/m.

Description : A three phase 50 Hz line consists of three conductors each of diameter 21 mm, The spacing between the conductors all follows:A - B = 3m, B - C = 5m, C - A = 3.6mIf the line operates at 132 k V, the reactive voltampere generatd by the line per km is?

Last Answer : A three phase 50 Hz line consists of three conductors each of diameter 21 mm, The spacing between the conductors all follows:A - B = 3m, B - C = 5m, C - A = 3.6mIf the line operates at 132 k V, the reactive voltampere generated by the line per km is  51.70 kVAr.

Description : A two conductor 1 - pi line operates at 50 Hz.The diameter of each conductor is 4 cm and are spaced 6 m apart. What is the capacitive susceptance to neutral per km?

Last Answer : A two conductor 1 - pi line operates at 50 Hz. The diameter of each conductor is 4 cm and are spaced 6 m apart. 3.06 x 10-9 s/km is the capacitive susceptance to neutral per km.

Description : A two conductor 1 - pi line operates at 50 Hz. The diameter of each conductor is 2 cm and are spaced 3m apart. What is the line to line capacitance ?

Last Answer : A two conductor 1 - pi line operates at 50 Hz. The diameter of each conductor is 2 cm and are spaced 3m apart.  4.87 x 10-9 F/km is the line to line capacitance.

Description : A two conductor 1 - pi line operates at 50 Hz. The diameter of each conductor is 20 mm and the spacing between conductors is 3m. What is the inductance of each conductor per km?

Last Answer : A two conductor 1 - pi line operates at 50 Hz. The diameter of each conductor is 20 mm and the spacing between conductors is 3m. 1.19 kH/km is the inductance of each conductor per km.

Description : The frequency of direct current is __. (1) Zero (2) 50 HZ (3) 60 HZ (4) 100 HZ

Last Answer : (1) Zero Explanation: Direct Current (DC) refers to power systems that use only one polarity of voltage or current, and to refer to the constant, zero-frequency, or slowly varying local mean value of a voltage or current.

Description : The frequency of direct current is _______ (1) Zero (2) 50 HZ (3) 60 HZ (4) 100 HZ

Last Answer : Zero

Description : An industrial consumer hall a daily load pattern of 2000 KW, 0.8 lag for 12 Hra and 1000 kW UPF for 1J Hr. The load factor i= _____. 

Last Answer : An industrial consumer hall a daily load pattern of 2000 KW, 0.8 lag for 12 Hra and 1000 kW UPF for 1J Hr. The load factor i= 0.6 . 

Description : The eddy current loss in an a-c electric motor is 100 watts at 50 Hz. Its loss at 100 Hz will be (A) 25 watts (B) 59 watts (C) 100 watts (D) 400 watts

Last Answer : (D) 400 watts

Description : A transformer at 25 Hz develops 20 W hysteresis loss and 50 W eddy current loss. If the applied voltage and frequency are doubled, the new core losses are (A) 140 W (B) 180 W (C) 240 W (D) 480 W

Last Answer : A transformer at 25 Hz develops 20 W hysteresis loss and 50 W eddy current loss. If the applied voltage and frequency are doubled, the new core losses are 240 W

Description : A 100 km long transmission line is loaded at 110 kV.if the loss of line is 5 MW and the load is 150 MVA, the resistance of the line is?

Last Answer : P = I^2  *  R 5*10^6  = [(150*10^6) / (110*10^3)  *  R R = 2.7 ohm/phase

Description : A turbogenerator has a rated output of 1200 KW at 60 Hertz, with a no load frequency of 61.5 Hertz. What is its speed droop? A. 1.03% B. 1.50% C. 2.44% D. 2.50%

Last Answer : Answer: D

Description : Which statement out of the following statements about ‘corona’ is incorrect? A) Corona gives rise to radio interference B) Corona results in loss of power in transmission C) Corona discharge can be observed as red luminescence D) Corona is always accompanied by a hissing voice

Last Answer : Which statement out of the following statements about ‘corona’ is incorrect? A) Corona gives rise to radio interference B) Corona results in loss of power in transmission C) Corona discharge can be observed as red luminescence D) Corona is always accompanied by a hissing voice

Description : Corona losses are minimized when?

Last Answer : Corona losses are minimized when smooth conductor is reduced.

Description : Transmission voltage of ll kV is normally used for distances upto (a) 20—25 km (b) 40—50 km (c) 60—70 km (d) 80—100 km

Last Answer : (a) 20—25 km

Description : At what loudness level do pitch (in mels) and frequency (in Hz) are numerically equal? A. 0 dB B. 20 dB C. 60 dB D. 40 dB

Last Answer : D. 40 dB

Description : Six (6) MHz crystal oscillator has a stability of 1 part in 106. The largest frequency error expected of this crystals A) 0.06 Hz B) 0.6 Hz C) 6 Hz D) 60 Hz.

Last Answer : C) 6 Hz

Description : Calculate natural frequency of damped vibration, if damping factor is 0.52 and natural frequency of the system is 30 rad/sec which consists of machine supported on springs and dashpots. A 21 rad/sec B 25.62 rad/sec C 20.22 Hz D 3.15 Hz

Last Answer : B 25.62 rad/sec

Description : A spring mass system has time period of oscillation of 0.25 sec. What will be the natural frequency of the system? A 1 Hz B 2 rad sec C 4 rad/sec D 4 Hz

Last Answer : D 4 Hz

Description : A vehicle suspension system consists of a spring and a damper. The stiffness of the spring is 3.6 kN/m and the damping constant of the damper is 400 Ns/m. If the mass is 50 kg, then the damping factor (d ) and damped natural ... , are a) 0.471 and 1.19 Hz b) 0.471 and 7.48 Hz c) 0.666 and 1.35 Hz

Last Answer : a) 0.471 and 1.19 Hz

Description : A vehicle suspension system consists of a spring and a damper. The stiffness of the spring is 3.6 kN/m and the damping constant of the damper is 400 Ns/m. If the mass is 50 kg, then the damping factor (d ) and damped natural ... .19 Hz b) 0.471 and 7.48 Hz c) 0.666 and 1.35 Hz d) 0.666 and 8.50 Hz

Last Answer : a) 0.471 and 1.19 Hz

Description : In a braking test, a vehicle travelling at 36 km ph was stopped at a braking distance of 8.0 m. The average value of the vehicle's skid resistance (friction coefficient) is (A) 0.64 (B) 6.25 (C) 0.16 (D) None of these

Last Answer : Answer: Option C

Description : The primary winding of a 220/6 V, 50 Hz transformer is energised from 110 V, 60 Hz supply. The secondary output voltage will be (A) 3.6 V. (B) 2.5 V. (C) 3.0 V. (D) 6.0 V.

Last Answer : (C) 3.0 V.

Description : Two alternators rated are 200 KW at 4% regulation, 400 KW 5% regulation operating in parallel at 50HZ , when supply 600 KW the new frequency is a) 50 b) 49 c) 51.3 d) 47.7

Last Answer : Ans: 47.7

Description : Determine natural frequency of a system, which has equivalent spring stiffness of 43200 N/m and mass of 12 kg. A 40.22 rad/sec B 40 Hz C 60 Hz D 60 rad/sec

Last Answer : D 60 rad/sec

Description : Extra widening required at a horizontal curve on a single lane hill road of radius 80 m for a design speed of 50 km ph and for a vehicle with wheel base 6.0 m is (A) 0.225 m (B) 0.589 m (C) 1.250 m (D) None of these

Last Answer : Answer: Option B

Description : The frequency of a wave travelling at a speed of 500 ms-1 is 25 Hz. Its time period will be ______. (i) 20 s (ii) 0.05 s (iii) 25 s (iv) 0.04 s

Last Answer : (iv) 0.04 s

Description : A 50 KVA transformer has iron loss 2 kW on full load. Calculate its iron loss at 75% of full load.

Last Answer : Iron loss is dependent on voltage and independent of load. Hence iron loss at 75% of Load = Iron loss at full load = 2 kW

Description : Slip of the induction machine is 0.02 and the stator supply frequency is 50 Hz. What will be the frequency of the rotor induced emf? (A) 10 Hz. (B) 50 Hz. (C) 1 Hz. (D) 2500 Hz.

Last Answer : Ans: C Given : s = 0.02 ; f = 50 Hz Therefore, frequency of rotor induced emf = s f = 0.02 x 50 = 1.0 Hz