Description : For which of the following protection from negative sequence currents is provided ? (a) Generators (b) Motors (c) Transmission line (d) Transformers
Last Answer : (a) Generators
Description : The under voltage relay can be used for (a) generators (b) busbars (c) transformers (d) motors (e) all of the above
Last Answer : (e) all of the above
Description : Overfluxing protection is recommended for (a) distribution transformer (b) generator transformer of the power plant (c) auto-transformer of the power plant (d) station transformer of the power plant
Last Answer : (b) generator transformer of the power plant
Description : For which of the following ratings of the transformer differential protection is recommended ? (a) above 30 kVA. (b) equal to and above 5 MVA (c) equal to and above 25 MVA (d) none of the above
Last Answer : (b) equal to and above 5 MVA
Description : A thermal protection switch can protect against (a) short-circuit (b) temperature (c) overload (d) over voltage
Last Answer : (c) overload
Description : Which of the following is the least expensive protection for overcurrent is low voltage system ? (a) Rewireable fuse (b) Isolator (c) Oil circuit breaker (d) Air break circuit breaker (e) None of the above
Last Answer : (a) Rewireable fuse
Description : A transmission line is protected by (a) inrush protection (b) distance protection (c) time graded and current graded over current protection (d) both (b) and (c) (e) none of the above
Last Answer : (d) both (b) and (c)
Description : Ungrounded neutral transmission system is not recommended because of system (a) insulation being overstressed due to over voltages (b) insulation overstress may lead to failure and subsequent phase to phase faults (c) being inadequately protected against ground fault (d) all of the above
Last Answer : (d) all of the above
Description : The inverse definite mean time relays are used for over current and earth fault protection of transformer against (a) heavy loads (b) internal short-circuits (c) external short-circuits (d) all of the above
Last Answer : (b) internal short-circuits
Description : For the protection of power station buildings against direct strokes the requirements are (a) interception (b) interception and conduction (c) interception, conduction and dissipation (d) interception, conduction, dissipation and reflection (e) none of the above
Last Answer : (c) interception, conduction and dissipation
Description : Consider efficiencies of hydro-turbines and generators. If the efficiency of a hydro-turbine is 80% and the efficiency of a generator is 90%, what is the overall efficiency of the unit? w) 85% x) 72% y) 90% z) 70%
Last Answer : ANSWER: X -- 72%
Description : The single phasing relays are used for the protection of (a) single phase motors only (b) two phase motors only (c) two single phase motors running in parallel (d) three phase motors
Last Answer : (d) three phase motors
Description : Discrimination between main and back up protection is provided by the use of relays which are (a) fact (b) sensitive (c) slow (d) none of the above
Last Answer : (c) slow
Description : The delay fuses are used for the protection of ________ . (a) motors (b) power outlet circuits (c) fluorescent lamps (d) light circuits
Last Answer : (a) motors
Description : H.R.C. fuses provide best protection against (a) overload (b) reverse current (c) open-circuits (d) short-circuits
Last Answer : (d) short-circuits
Description : Large internal faults are protected by (a) merz price percentage differential protection (b) mho and ohm relays (c) horn gaps and temperature relays (d) earth fault and positive sequence relays
Last Answer : (a) merz price percentage differential protection
Description : The contacts of high voltage switches used in power system are submerged in oil. The main purpose of the oil is to (a) lubricate the contacts (b) insulate the contacts from switch body (c) extinguish the arc (d) all of the above (e) none of the above
Last Answer : (c) extinguish the arc
Description : The voltage appearing across the contacts after opening of the circuit breaker is called______voltage. (a) recovery (b) surge (c) operating (d) arc (e) none of the above
Last Answer : (a) recovery
Description : Relays can be designed to respond to changes in (a) resistance, reactance or impedance (b) voltage and current (c) light intensity (d) temperature (e) all above
Last Answer : (e) all above
Description : What is re-striking voltage?
Last Answer : The Re-striking voltage may be defined as the resultant transient voltage which appears across the breaker contacts at the instant of arc extinction
Description : What is recovery voltage in circuit breaker?
Last Answer : Recovery voltage in circuit breakers is defined as the power frequency rms voltage which appears across the breaker contacts after the transient oscillations die out and the final extinction of the arc ... poles of the circuit breaker. It is the voltage developed after the arc extinction is competed
Description : Series capacitors are used to (a) compensate for line inductive reactance (b) compensate for line capacitive reactance (c) improve line voltage (d) none of the above
Last Answer : (a) compensate for line inductive reactance
Description : Arc in a circuit breaker is interrupted at (a) zero current (b) maximum current (c) minimum voltage (d) maximum voltage
Last Answer : (a) zero current
Description : Which of the following devices will receive voltage surge first travelling on the transmission line ? (a) Lightning arresters (b) Relays (c) Step-down transformer (d) Switchgear
Last Answer : (a) Lightning arresters
Description : The short circuit in any winding of the transformer is the result of (a) mechanical vibration (b) insulation failure (c) loose connection (d) impulse voltage
Last Answer : (d) impulse voltage
Description : Induction cup relay is operated due to changes in (a) current (b) voltage (c) impedance (d) all of the above
Description : Resistance grounding is used for voltage between (a) 33kVto66kV (b) HkVto33kV (c) 3.3kVandllkV (d) none of the above
Last Answer : (c) 3.3kVandllkV
Description : Insulation resistance of high voltage circuit breakers is more than (a) 1 mega ohms (b) 10 mega ohms (c) 100 mega ohms (d) 500 mega ohms
Last Answer : (c) 100 mega ohms
Description : The arc voltage produced in A.C. circuit breaker is always (a) in phase with the arc current (b) lagging the arc current by 90" (c) leading the arc current by 90° (d) none of the above
Last Answer : (a) in phase with the arc current
Description : Protective relays are devices that detect abnormal conditions in electrical circuits by measuring (a) current during abnormal condition (b) voltage during abnormal condition (c) constantly the electrical quantities which differ during normal and abnormal conditions (d) none of the above
Last Answer : (c) constantly the electrical quantities which differ during normal and abnormal conditions
Description : When a transmission line is energized, the wave that propagates on it is (a) current wave only (b) voltage wave only (c) both (a) and (b) (d) power factor wave only
Last Answer : (c) both (a) and (b)
Description : Directional relays are based on flow of (a) power (b) current (c) voltage wave (d) all of the above
Last Answer : (a) power
Description : In order that current should flow without causing excessive heating or voltage drop, the relay contacts should (a) have low contact resistance (b) be clean and smooth (c) be of sufficient size and proper shape (d) have all above properties
Last Answer : (d) have all above properties
Description : Arc in a circuit behaves as (a) a capackive reactance (b) an inductive reactance (c) a resistance increasing with voltage rise across the arc (d) a resistance decreasing with voltage rise across the arc
Last Answer : (d) a resistance decreasing with voltage rise across the arc
Description : SF6 gas (a) is yellow in colour (b) is lighter than air (c) is nontoxic (d) has pungent small (e) none of the above
Last Answer : (c) is nontoxic
Description : Which of the following circuit breakers has high reliability and minimum maintenance ? (a) Air blast circuit breakers (b) Circuit breaker with SF6 gas (c) Vacuum circuit breakers (d) Oil circuit breakers
Last Answer : (b) Circuit breaker with SF6 gas
Description : Which type of pole generators are used in Hydro-electric plants and why?
Last Answer : A: As the speed of operation is low for hydro turbines used in Hydro-electric plants, salient pole type Synchronous generators are used. These allow better ventilation and also have other advantages over smooth cylindrical type rotor.They have more diameter and less axial length.
Description : Air blast circuit breaker is used for (a) over currents (b) short duty (c) intermittant duty (d) repeated duty
Last Answer : (d) repeated duty
Description : Thermal overload relays are used to protect the motor against over current due to (a) short-circuits (b) heavy loads (c) grounds (d) all of the above
Last Answer : (b) heavy loads
Description : transmission line has reflection coefficient as one. (a) Open circuit (b) Short-circuit (e) Long (d) None of the above
Last Answer : (a) Open circuit
Description : The relay with inverse time characteristic will operate within (a) 1.5 sec (b) 5 to 10 sec (c) 5 to 20 sec (d) 20 to 30 sec (e) none of the above
Last Answer : (b) 5 to 10 sec
Description : Short-circuit currents are due to (a) single phase to ground faults (b) phase to phase faults (c) two phase to ground faults (d) three phase faults (e) any of these
Last Answer : (e) any of these
Description : A.C. network analyser is used to solve problems of (a) load flow (b) load flow and short-circuit (c) load flow and stability (d) load flow, short-circuit and stability (e) none of the above
Last Answer : (d) load flow, short-circuit and stability
Description : When a wave propagates on a transmission line, it suffers reflection several times at (a) tapping (b) load end (c) sending end (d) sending and other end (e) all of the above
Last Answer : (d) sending and other end
Description : The line insulation is the insulation level of the station equipment. (a) less than (b) same as (c) more than (d) proportional to (e) not directly related with
Last Answer : (e) not directly related with
Description : The time of closing the cycle, in modern circuit breakers is (a) 0.003 sec (b) 0.001 sec (c) 0.01 sec (d) 0.10 sec (e) none of the above
Last Answer : (a) 0.003 sec
Description : The current zero interruption, in oil and air blast circuit breakers, is achieved by (a) lengthening of the gap (b) cooling and blast effect (c) both (a) and (b) (d) deionizing the oil with forced air (e) none of the above
Description : Circuit breakers are essentially (a) current carrying contacts called electrodes (b) arc extinguishers (c) circuits to break the system (d) transformers to isolate the two systems (e) any of the above
Last Answer : (a) current carrying contacts called electrodes
Description : Overload relays are of...... type. (a) induction (b) solid state (c) thermal (d) electromagnetic (e) all above
Description : With which of the following, a circuit breaker must be equipped for remote operation ? (a) Inverse time trip (b) Time-delay trip (c) Shunt trip (d) None of the above (e) All of the above
Last Answer : (c) Shunt trip