The full load torque of an electric motor is the __________. A. minimum torque developed by the motor accelerating from stop to full speed B. turning moment exerted by the motor at rated load and speed C. maximum torque developed by the motor with rated voltage and frequency D. turning moment exerted by the motor from any rotor angular position at any load

1 Answer

Answer :

Answer: B

Related questions

Description : A split-phase induction squirrel-cage motor will not come up to speed, even though the rated voltage, rated frequency, and rated load are applied. The suspected trouble could be due to _____________. A. a faulty centrifugal switch B. broken rotor bars C. worn bearings D. all of the above

Last Answer : Answer: D

Description : Regarding an induction motor, the power developed by the rotor automatically adjusts itself to the _____________. A. power required to drive the load B. speed required to drive the load C. current flow in the motor stator D. torque developed by the rotating field

Last Answer : Answer: A

Description : The torque produced by a motor when its shaft will not turn, even though rated voltage is applied to the stator, is known as _____________. A. locked-rotor torque B. pullout torque C. breakdown torque D. torque margin

Last Answer : Answer: A

Description : The rate of change of moment of momentum represents the __________ by the fluid. (A) Torque applied (B) Force exerted (C) Work done (D) Power developed

Last Answer : (A) Torque applied

Description : A 3-phase induction motor is driving a constant torque load at rated voltage and frequency. If both voltage and frequency are halved, following statements relate to the new condition if stator resistance, leakage reactance and core loss are ... (A) All (B) 1, 2 and 3 (C) 2, 3 and 4 (D) 1 and 4

Last Answer : A 3-phase induction motor is driving a constant torque load at rated voltage and frequency. If both voltage and frequency are halved, following statements relate to the new condition if stator resistance, leakage reactance and core loss are ... A) All (B) 1, 2 and 3 (C) 2, 3 and 4 (D) 1 and 4

Description : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m.

Last Answer : (D) 75 r.p.m.

Description : Reduced voltage applied to a motor during the starting period will _____________. A. result in decreased acceleration time only B. lower the starting current and increase accelerating time C. cause a greater starting torque D. increase the starting current and pump capacity

Last Answer : Answer: B

Description : A characteristic of a wound-rotor induction motor, with a high resistance rotor winding, is _____________. A. low starting torque B. high starting torque C. high speed D. low starting voltage

Last Answer : Answer: B

Description : If the centrifugal switch or relay used for cutting out the starting winding of a split-phase induction motor fails to open once the motor is in operation, the _____________. A. motor will overspeed B ... C. motor will immediately stall under load D. motor torque will be above normal at rated speed

Last Answer : Answer: B

Description : A dc cumulatively compounded motor delivers rated load torque at rated speed. If series field is short circuited, then the armature current and speed will a) Both increases b) Both decreases c) Increases and decreases d) Decreases and increases

Last Answer : Ans: Both increases

Description : If an induction motor were to be operated at 90% rated voltage, _____________. A. there would be an increase in starting torque B. starting current would increase slightly C. synchronous speed would decrease slightly D. the slip would increase

Last Answer : Answer: D

Description : The speed of a squirrel-cage, multi-speed, induction motor, as used aboard ship, is varied by changing the __________. A. number of connected poles in the stator B. frequency to the motor C. excitation voltage D. resistance of the rotor circuit

Last Answer : Answer: A

Description : The variable resistance placed in the rotor circuit of a wound-rotor induction motor provides for __________. A. speed control B. frequency control C. voltage control D. use as a split-phase motor

Last Answer : Answer: A

Description : The torque and current curves for a three-phase induction motor with a cage rotor, are shown in the illustration. Which of the following statements is true concerning the depicted curves? EL-0056 A. As slip ... D. If the motor is loaded to the point where 40% slip has resulted, it will stall.

Last Answer : Answer: D

Description : In a 15 HP induction-type motor with a cage rotor, the current required at standstill to produce starting torque is approximately ____________. A. half the full load current B. equal to the full load current C. five times the full load current D. ten to twenty times the full load current

Last Answer : Answer: C

Description : The frequency of the rotor current in a 3 phase 50 Hz, 4 pole induction motor at full load speed is about (A) 50 Hz. (B) 20 Hz. (C) 2 Hz. (D) Zero.

Last Answer : (C) 2 Hz.

Description : If a three-phase induction motor malfunctions and drops to a single-phase (one supply line open) ____________. A. the motor will continue to run if it is not heavily loaded B. more torque will be ... be able to be restarted D. the motor will immediately stop and can only be restarted at no load

Last Answer : Answer: A

Description : In case of a universal motor, torque pulsation is minimized by _________. (A) load inertia (B) rotor inertia (C) both rotor and load inertia (D) none of the above

Last Answer : Ans: C In a universal motor, torque pulsation is minimized by rotor and load inertia.

Description : If the driving torque, such as that produced by a diesel engine, creates pulsations when coupled with a synchronous generator operating in parallel; the generator rotor may be periodically pulled ... windings B. direct coupling C. increase governor speed droop D. decreasing governor speed droop

Last Answer : Answer: A

Description : The speed of a multi-speed, squirrel-cage, induction motor operating in a fixed frequency system can be changed by _____________. A. reconnecting stator windings for different numbers of poles B. ... sequence of the applied voltage D. reconnecting the stator so that no poles have the same polarity

Last Answer : Answer: A

Description : Under normal conditions, the speed of a two-speed squirrel cage induction motor is changed by varying the ____________. A. frequency of the applied voltage B. resistance in the rotor circuit C. number of field poles D. amplitude of the applied voltage

Last Answer : Answer: C

Description : A 3-phase, 400 votts, 50 Hz, 100 KW, 4 pole squirrel cage induction motor with a rated slip of 2% will have a rotor speed of (A) 1500 rpm (B) 1470 rpm (C) 1530 rpm (D) 1570 rpm

Last Answer : Ans: B N = NS (1-S) and NS =120 f / p =120 x 50 /4 = 1500 rpm ∴N= 1500 (1-0.02) =1470 rpm

Description : The purpose of a cage rotor winding placed on the rotor of a synchronous motor is to _____________. A. provide excitation to the DC field B. start the machine as an induction motor C. contribute extra torque at synchronous speed D. prevent the machine from falling out of step

Last Answer : Answer: B

Description : The counter EMF of a DC motor is maximum when the _________. A. motor is at rated speed B. armature is not turning C. motor is almost up to rated speed D. armature has just begun to turn

Last Answer : Answer: A

Description : If a three-phase induction motor is operated under a light load and it develops an open in one of its supply lines, the motor will _____________. A. continue to run, but will vibrate and have reduced ... speed up due to the reduced number of poles C. run cooler due to reduced current flow D. stop

Last Answer : Answer: A

Description : You are attempting to parallel two AC generators and the synchroscope pointer stops at a position other than 0°. If you close the circuit breaker at this moment _____________. A. the incoming ... hazardous condition will be created by the incoming machine being at a higher frequency than the bus

Last Answer : Answer: C

Description : The power factor of an AC generator operating singularly is determined by the __________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: A

Description : What is the rotor speed of a four pole, 60 cycle, induction motor operating at full load with 3% slip? A. 270 RPM B. 540 RPM C. 873 RPM D. 1746 RPM

Last Answer : Answer: D

Description : The speed of a wound-rotor induction motor _____________. A. will be fixed by the number of field poles B. can be varied by a rheostat-type control C. can only be synchronous speed at full load D. can only attain synchronous speed at no load

Last Answer : Answer: B

Description : Which of the following actions must be carried out before a voltage tester can be used to test the three line fuses to a three-phase motor? A. The fuses must be removed from the circuit. B. The ... disconnected and tagged. D. Nothing need be done as long as the motor is running under a light load.

Last Answer : Answer: B

Description : The twisting force developed by a motor and applied to a shaft is called _____________. A. magnetism B. electromotive force C. torque D. voltage

Last Answer : Answer: C

Description : If the driving torque, such as that produced by a diesel engine, creates pulsations when coupled with a synchronous generator operating in parallel; the generator rotor may be periodically pulled ahead or behind ... as it rotates. This co A. hunting B. direct coupling C. peaking D. harmonic coupling

Last Answer : Answer: A

Description : A three phase induction motor is driving full -load torque which is independent of speed. If the line voltage drops to 90% of the rated value, % increase in motor copper losses  (a) 23% (b) -18% (c) 123% (d) None of these

Last Answer : A three phase induction motor is driving full -load torque which is independent of speed. If the line voltage drops to 90% of the rated value, % increase in motor copper losses (a) 23% (b) -18% (c) 123% (d) None of these

Description : Which of the following statements is true concerning a polyphase synchronous propulsion motor? A. The motor is started as an induction motor. B. Resistance is gradually added to the rotor circuit. C. ... is held below the rated current. D. The field winding is energized for starting purposes only.

Last Answer : Answer: A

Description : The full torque electric brake on an electric cargo winch functions to _____________. A. act as a backup brake in the event the mechanical brake should fail B. automatically hold the load ... automatically govern the lowering speed of the load D. automatically govern the hoisting speed of the load

Last Answer : Answer: B

Description : The rated temperature rise of an electric motor is the _____________. A. average temperature at any given latitude B. normal temperature rise above the standard ambient temperature at rated load ... D. permissible difference in the ambient temperature of the motor due to existing weather conditions

Last Answer : Answer: B

Description : The counter EMF produced in the windings of a DC motor is 'zero' when the ____________. A. armature has just begun to turn B. armature is not turning C. motor is almost up to rated speed D. motor is at rated speed

Last Answer : Answer: B

Description : When a synchronous motor is running at synchronous speed, the damper winding produces (A) damping torque. (B) eddy current torque. (C) torque aiding the developed torque. (D) no torque.

Last Answer : (D) no torque.

Description : The rotor slots of a repulsion-type motor are generally skewed (placed nonparallel to the rotor axis) to _________. A. produce a constant starting torque B. permit a greater air gap with the starter C. permit a smaller air gap with the starter D. reduce eddy current losses

Last Answer : Answer: A

Description : A single-phase induction motor having a relatively high starting torque, is the ___________. A. shaded pole motor B. wound-rotor motor C. capacitor-start motor D. resistance-start motor

Last Answer : Answer: C

Description : The torque produced by a DC motor armature is the product of the force acting at the armature surface multiplied by _____________. A. work done by the armature in one revolution B. effective ... arm at the center of rotation of the armature D. perpendicular distance to its center of rotation

Last Answer : Answer: D

Description : Which of the following statements is true concerning the operating characteristics of a squirrel-cage motor? A. Rotor slip is dependent upon the motor load. B. An increase in motor load results in ... results in less generated current. D. A decrease in rotor speed produces a weaker magnetic field.

Last Answer : Answer: A

Description : The synchronous speed of an induction motor is the ________. A. speed at which the rotor turns B. speed of the rotating field C. frequency of the rotor current D. slip in per cent of rotor RPM

Last Answer : Answer: B

Description : The speed of a three-phase squirrel-cage induction-type motor operating in a fixed frequency system is varied by changing the _____________. A. number of phases to the motor B. number of stator poles C. locked rotor current D. resistance of the rotor winding

Last Answer : Answer: B

Description : In Induction motor Slip frequency of rotor current, when rotor speed is Nr. Then rotor producing slip field rotates with respect to stator is a) Slip frequency b) Nr c) Ns d) None

Last Answer : Ans: Ns

Description : The synchronous speed for a 3 phase 6-pole induction motor is 1200 rpm. If the number of poles is now reduced to 4 with the frequency remaining constant, the rotor speed with a slip of 5% will be _________. (A) 1690 rpm (B) 1750 rpm (C) 1500 rpm (D) 1710 rpm

Last Answer : (D) 1710 rpm

Description : The frequency output of an operating alternator is controlled by the _____________. A. relative speed of the rotor poles B. number of turns of wire in the armature coil C. strength of the magnets used D. output voltage

Last Answer : Answer: A

Description : A dc series motor driving and electric train faces a constant power load. It is running at rated speed and rated voltage. If the speed has to be brought down to 0.25 p.u. the supply voltage has to be approximately brought down to  (A) 0.75 p.u (B) 0.5 p.u (C) 0.25 p.u (D) 0.125 p.u

Last Answer : A dc series motor driving and electric train faces a constant power load. It is running at rated speed and rated voltage. If the speed has to be brought down to 0.25 p.u. the supply voltage has to be approximately brought down to 0.5 p.u

Description : The speed of a d.c. shunt motor at no-load is (A) 5 to 10% (B) 15 to 20% (C) 25 to 30% (D) 35 to 40% higher than its speed at rated load.

Last Answer : (A) 5 to 10%