Consider the following statements 

1) The compensating coil of a low power factor wattmeter compensates the effect of the impedance of the current coil ii) The compensating coil of a low power factor wattmeter compensates the effect of the impedance of the voltage coil circuit 

A) (i) is true but (ii) is false B) (i) is false but (ii) is true C) Both (i) and (ii) are true D) Both (i) and (ii) are false

2 Answers

Answer :

Consider the following statements 

1) The compensating coil of a low power factor wattmeter compensates the effect of the impedance of the current coil ii) The compensating coil of a low power factor wattmeter compensates the effect of the impedance of the voltage coil circuit 

A) (i) is true but (ii) is false B) (i) is false but (ii) is true C) Both (i) and (ii) are true D) Both (i) and (ii) are false

Answer :

A

Related questions

Last Answer : In a low power factor wattmeter the compensating coil is connected in series with pressure coil.

Last Answer : In a low power factor wattmeter the pressure coil is connected to the load side of the current coil.

Description :  In dynamometer type of wattmeter, which of the coil is split up into two parts?

Last Answer :  In dynamometer type of wattmeter, which of the coil is split up into two parts?  current coil

Description : The pressure coil of a dynamometer type wattmeter is  A) Highly inductive B) Highly resistive C) Purely resistive D) Purely inductive

Last Answer : highly resistive

Description : The current coil of a wattmeter is connected to the CT of R-phase. The potential coil is connected across Y and B phases. The wattmeter measures

Last Answer : The current coil of a wattmeter is connected to the CT of R-phase. The potential coil is connected across Y and B phases. The wattmeter measures Reactive power of R phase.

Last Answer : The pressure coil of a wattmeter should be connected on the supply side of the current coil when load impedance is high.

Last Answer : The resistance in the circuit of the moving coil of a dynamometer wattmeter should be high.

Description : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging:

Last Answer : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging: One of the wattmeter connections will have to be reversed

Description : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3-phase 3 ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Last Answer : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3- ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Description : The true power indicated by a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the _____________. A. power factor of the load B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load

Last Answer : Answer: A

Description : The true power indicated by the pointer movement of a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the ____________. A. power factor of the ... B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load

Last Answer : Answer: A

Description : Martin’s factor compensates for curvature effect in springs. a) True b) False

Last Answer : b) False

Description : The basic meter movement responds to the flow of current through its coil. Therefore, this meter movement may be used as a/an _____________. A. voltmeter by placing a resistance in parallel with the ... in parallel with the coil D. ammeter by placing a low resistance in parallel with the coil

Last Answer : Answer: D

Description :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the connections of current coil. the ... kVAR B) 0.2 & 6 √3 kVAR C) 0.32 & 2 kVAR D) 0.32 & 2 √3 kVAR

Last Answer :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the ... of current coil. the power factor and reactive power of the load is 0.2 & 6 √3 kVAR

Description : While measuring power in a three phase load by two wattmeter method, the reading of two wattmeter are equal and opposite, when (a) load is balanced (b) power factor is unity (c) phase angle is between 60° to 90° (d) the load is purely inductive 

Last Answer :  Option (d)  Load is purely inductive 

Description : The minimum number of wattmeter(s) required to measure 3-phase, 3-wire balanced or unbalanced power is  A) 1 B) 2 C) 3 D) 4

Last Answer : B

Description : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is (A) Zero (B) Leading (C) Lagging (D) Unity

Last Answer : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is Unity

Last Answer : In the case of power measurement by two wattmeter method in a balanced 3Φ system with a pure inductive load both the Wattmeter will indicate the same but of opposite sign.

Description : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be?

Last Answer : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be 0.5.

Description : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was?

Last Answer : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was unity.

Description : Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be

Last Answer : Two wattmeter method is employed to measure power in a 3 -phase balanced system with the current coil connected in the A and C lines. The phase sequence is ABC. If the wattmeter with its current coil in A -phase line reads zero, then the power factor of the 3 -phase load will be 0.5 lagging.

Description : A current carrying conductor making an electrical contact with a wiring metal conduit is indicated by a _____________. A. low switchboard wattmeter reading B. reading of 1.0 on the power factor meter C. high switchboard voltmeter reading D. totally darkened switchboard ground-detecting light

Last Answer : Answer: D

Description : Consider the following statements with regard to induction type wattmeter :  1. Can be used on both ac and dc systems.  2. Power consumption is relatively low.  3. It is accurate only at stated frequency and temperature.  Which ... /are correct ?  (a) 1 only (b) 2 only (c) 3 only (d) 1, 2 and 3

Last Answer : Consider the following statements with regard to induction type wattmeter :  1. Can be used on both ac and dc systems.  2. Power consumption is relatively low.  3. It is accurate only at stated frequency and temperature. ... correct ?  (a) 1 only (b) 2 only (c) 3 only (d) 1, 2 and 3

Description : A wattmeter is connected as shown in the figure. The wattmeter reads 

Last Answer : A wattmeter is connected as shown in the figure. The wattmeter reads Power consumed by Z2

Description : Poynting vector wattmeter is based on   (A) Seebeck effect (B) Ferranti effect (C) Induction effect (D) Hall effect

Last Answer : Poynting vector wattmeter is based on Induction effect 

Description : The torque produced in wattmeter is proportional to

Last Answer : A

Last Answer : Wattmeter cannot be designed on the principle of moving iron instrument.

Last Answer : An induction wattmeter can be used for A.C. 

Last Answer : A dynamometer wattmeter can be used for both D.C. and A.C.

Description : Moving coil in dynamometer wattmeter connected a) In series with fixed coil b) Across supply c) In series with load d) Across load

Last Answer : Ans: Across supply

Description : Explain the error occurred due to pressure coil inductance of electrodynamometer type wattmeter. How this error is compensated?

Last Answer : For power measurement assume that the pressure coil of wattmeter is purely restitive. Hence current taken by pressure coil Ipc is in phase with voltage across the pressure coil Vpc  ... inductive reactance XL the pressure coil circuit is made purely resistive and the error is eliminated.

Description : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is (A) 11% (B) 9% (C) 1.1% (D) 3%

Last Answer : The potential coil of a single phase dynamometer wattmeter has 4840 Ohm resistance. Voltage across the load is 220 V. With the potential coil connected on the load side, the meter indicates 100 W. Approximate percentage error due to wattmeter connection is 11%

Description :  Moving coil in dynamometer wattmeter connected : - a) in series with fixed coil b) across supply c) in series with load d) across load

Last Answer : Moving coil in dynamometer wattmeter connected : - across supply

Description : Which one of the following statements for a dc machine which is provided with inter pole winding (IW) as well as compensating winding (CW) is correct a) Both IW and CW are connected in ... parallel with Armature winding d) CW connected in series but IW is connected in parallel with Armature winding

Last Answer : Ans: Both IW and CW are connected in series with Armature winding

Last Answer : A moving-coil permanent-magnet instrument can be used as ammeter by using a low resistance shunt.

Description : To increase crop production, food engineers combine two plants so that each plant's strength compensates for the other's weakness. What is this technique called?

Last Answer : plant breeding

Description : While dusting a carpet, we give a sudden jerk or beat it with a stick because _____. A. Inertia of rest keeps the dust in its position and the dirt is removed by the movement of carpet away B. ... the force of adhesion between the dust and the carpet and the dust is removed D. None of the these

Last Answer : ANSWER: B

Description : Local action in a dry-cell, or lead-acid storage battery is the process whereby ________________. A. hydrogen gas is liberated B. the electrolyte compensates for overcharging C. potassium hydroxide ... carbon dioxide from the air D. the battery becomes discharged without being connected to a load

Last Answer : Answer: D

Description : Where a thermal-acting breaker is required to be used in an area of unusually high, low, or constantly fluctuating temperatures, an ambient compensating element must be used. This element consists of ... arm B. conical spring on the contact arm C. second bimetal element D. second electromagnet

Last Answer : Answer: C

Description : Which of the following meters uses a shunt connected in series with the load, but parallel with the meter movement? A. voltmeter B. power factor meter C. wattmeter D. ammeter

Last Answer : Answer: D

Description : Which of the listed meters uses a shunt connected in series with the load, but parallel with the meter movement? A. Voltmeter B. Power factor meter C. Ammeter D. Wattmeter

Last Answer : Answer: C

Description : A portable hand-held and is very handy for determining the power consumption and power factor of individual motors and other inductive devices. a) Voltmeter and wattmeter. b) Wattmeter and power factor meter. c) Light meter and flash meter.

Last Answer : Voltmeter and wattmeter.

Description : Explain the effect of power factor on wattmeter reading in two wattmeter method for power measurement.

Last Answer : Effect of P.F. on Reading of Wattmeter in Two Wattmeter Method:

Description : Silicon diodes designed for a specific reverse breakdown voltage, become useful as an electronic power supply voltage regulator, called _____________. A. tunnel diodes B. hot-carrier diodes C. compensating diodes D. Zener diodes

Last Answer : Answer: D

Description : A single phase wattmeter rated for 500 V; 5A is having full scale deflection of 1000 watt. What is multiplying factor of the wattmeter?

Last Answer : Answer :

Description : The magnetic field intensity at the centre of a current carrying coil of diameter J m is K. The current flowing in the coil is

Last Answer : The magnetic field intensity at the centre of a current carrying coil of diameter d m is H. The current flowing in the coil is dH

Description : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is:

Last Answer : A permanent magnet moving coil ammeter has a coil resistance of 99 ohm and Full Scale Deflection (FSD) current of 0.1mA. Shunt resistance is 1 ohm. Current through the meter at 0.5 F.S.D is: 0.05mA

Description : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect • 10 W resistance in series • 10 W resistance in parallel • 10/1999 W resistance in series • 10/1999 W resistance in parallel

Last Answer : A moving coil instrument has a resistance of 10 W and gives full scale deflection when carrying a current of 50 mA. To measure current upto 100 A, we will have to connect 10/1999 W resistance in parallel

Description : Permanent magnet moving coil instruments are used for

Last Answer : PMME are mostly used for measuring voltage and current.

Description : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is

Last Answer : A moving coil of meter has 100 turns, and a length and depth of 10mm and 20mm respectively. It is positioned in a uniform radial flux density of 200 mT. The coil carrier current capacity is 50 mA. The torque on the coil is 200µNm