What will be the reactive power and bus voltage whan the generator bus is treated as load bus.

1 Answer

Answer :

When the generator bus is treated as load bus, the reactive power of the bus is equated to the limit it has violated, and the previous iteration value of bus voltage is used for calculating current iteration value.

Related questions

Description : When the generator buses are treated as load bus.

Last Answer : If the reactive power constraints of a generator bus violates the specified limits then the generator is treated as load bus.

Description : Define voltage controlled bus(generator bus/PV bus).

Last Answer : A bus is called voltage controlled bus if the magnitude of voltage |V| and real power (P) are specified for it. In a voltage controlled bus, the magnitude of the voltage is not allowed to change. Voltage controlled bus is also called as Generator bus and PV bus.

Description : What is PQ bus (load bus)?

Last Answer : A bus is called PQ bus or load bus when real and reactive components of power are specified for the bus. In a load bus, the voltage is allowed to vary within permissible limits.

Description : Define voltage controlled bus?

Last Answer : A bus is called voltage controlled bus if the magnitude of volte\age and real power are specified for it. In a voltage controlled bus the magnitude of the voltage is not allowed to change.

Description : What is the need for slack bus

Last Answer : The slack bus is needed to account for transmission line losses. In a power system the total power generated will be equal to sum of power consumed by loads and losses. In a power system only ... for losses. Since the losses are unknown the real and reactive power are not specified for slack bus.

Description : What is PQ bus?

Last Answer : A bus is called PQ bus when real and reactive components of power are specified for the bus. In a load bus the voltage is allowed to vary within permissible limits. 46. What is swing bus? Abus ... it is required for accounting line losses. Usually one of the generator bus is selected as swing bus.

Description : What are the quantities associated with each bus ina system?

Last Answer : Each bus in a power system is associated with four quantities and they are real power, reactive power, magnitude of voltage, and phase angle of voltage.

Description : Write the four ways of adding an impedance to an existing system so as to modify bus impedance matrix.

Last Answer : 1. Adding a branch of impedanceZb from a new bus p to the referance bus. 2. Adding a branch of impedance Zb from a new busp to an existing bus. 3. Adding a branch of impedance Zb from an existing busq to the referance bus. 4. Adding a branch of impedance Zb between two existing buses h and q.

Description : What are the methods available for forming bus impedance matrix.

Last Answer : 1. Form the bus impedance matrix and then take its inverse to get bus impedance matrix. 2. Directly form the bus impedance matrix from the reactance diagram. This method utilizes the techniques of modifications of existing bus impedance matrix due to addition of new bus.

Description : Name the diagonal elements and off diagonal elements of bus impedance matrix.

Last Answer : The diagonal elements of bus impedance matrix are called driving point impedances of the buses and off diagonal elements of bus impedance matrix are called transfer impedances of the buses.

Description : What is bus imbedance matrix?

Last Answer : The matrix consisting of driving point impedances and transfer impedances of the network of a power system is called bus impedance matrix.

Description : Name the diagonal and off diagonal elements of bus admittance matrix.

Last Answer : The diagonal elements of bus admittance matrix are called self admittances of the buses and off diagonal elements are called mutual admittances of the buses.

Description : What is bus admittance matrix?

Last Answer : The matrix consisting of the self and mutual admittances of the network of a power system is called bus admittance matrix.

Description : What is a bus?

Last Answer : The meeting point of various components in a power system is called a bus. The bus is a conductor made of copper having negligible resistance. The buses are considered as a points of constant voltage in a system

Description : What is the need for slack bus?

Last Answer : The slack bus is needed to account for transmission line losses. In a power system, the total power generated will be equal to sum of power consumed by loads and losses. In a power system, ... power are not specified for slack bus. They are estimated through the solution of line flow equations.

Description : What is swing bus(slack bus/reference bus)?

Last Answer : A bus is called swing bus when the magnitude and phase of bus voltage are specified for it. The swing bus is the reference bus for load flow solution and it is required for accounting for the line losses. Usually one of the generator bus is selected as the swing bus.

Description : In power system, if a voltage controlled bus is treated as a load bus then which one of the following limits would be violated? a) Voltage b) Active power c) reactive power d) Phase angle

Last Answer : a) Voltage

Description : What is load flow or power flow study?

Last Answer : The study of various methods of solution to power system network is reffered to as load flow study. The solution provides the voltages at various buses, power flowing in various lines and line losses.

Description : What is power flow study or load flow study?

Last Answer : The study of various methods of solution to power system network is referred to as load study. The solution provides the voltages at various buses, power flowing in Various lines and line losses.

Description : Discuss the effect of acceleration factor in load flow study.

Last Answer : The acceleration factor is a real quantity and it modify the magnitude of voltage alone.

Description : What are the iterative methods mainly used for solution of load flow study.

Last Answer : The Guass sedal method and Newton Raphson method are the two iterative methods.

Description : What are the operating constraints imposed in the load flow studies?

Last Answer : The operating constraints imposed in load flow studies are reactive power limits for generator buses and allowable change in magnitude of voltagefor load buses.

Description : What is the need for load flow study.

Last Answer : The load flow study of a power system is essential to decide the best operation existing system and for planning the future expansion of the system. It is also essential for designing the power system.

Description : What are the information that are obtained from a load flow study.

Last Answer : The information obtained from a load flow study are magnatude and phase of bus voltages,real and reactive power flowing in each line and the line losses. T he load flow solution also gives the initial conditions of the system when the transient behaviour of the system to be studied.

Description : What are the works involved in a load flow study?

Last Answer : The following has to be performed for a load flow study. a. Representation of the system by single line diagram. b. Formation of impedance diagram using the information in single line diagram. c. Formulation of network equations d. Solution of network equations.

Description : What is the need for load flow study?

Last Answer : The load flow study of a power system is essential to decide the best operation of existing system and for planning the future expansion of the system. It is also essential for designing a new power system

Description : What are the information that are obtained from a load flow study?

Last Answer : The information obtained from a load flow study are magnitude and phase angles of bus voltages, real and reactive power flowing in each line and line losses. The load flow solution also gives the initial conditions of the system when the transient behavior of the system is to be studied.

Description : What is meant by flat voltage start.

Last Answer : In iterative methods of load flow solution, the initial voltages of all buses exept slack bus are assumed as 1+j0 pu.This is reffered as flat voltage profile.

Description : Define power angle

Last Answer : The power angle is defined as the angular displacement of the rotor from synchronously rotating referance frame.

Description : Why fault accurs in a power system?

Last Answer : The fault occur in a power system due to insulation failure of equipments, flashover of lines initiated by a lightning stroke, due to permanent damage to conductors and towers

Description : What are the different types of buses in a power system?

Last Answer : The buses of a power system can be classified into three types based on the quantities being specified for the buses, which are as follows: a. Load bus or PQ bus (P and Q are specified) b. Generator bus ... P and V are specified) c. Slack bus or swing bus or reference bus (|V| and δ are specified)

Description : Why power flow analysis is made?

Last Answer : Power flow analysis is performed to calculate the magnitude and phase angle of voltages at the buses and also the active power and reactive voltamperes flow for the given terminal or bus conditions. The variables ... | b. Phase angle of voltage δ c. Active power, P d. Reactive voltamperes, Q

Description : Write the most important mode of operation of power system and mention the major problems encountered with it.

Last Answer : Symmetrical steady state is the most important mode of operation of power system. Three major problems are encountered in this mode of operation. They are, 1) Load flow problem 2) Optimal load scheduling problem 3) Systems control problem

Description : As shown in the illustration, the function of the switch labeled 'PFSW' is to determine the ______________. EL-0003 A. bus frequency B. reactive volt amperes of the bus C. frequency of either generator D. power factor of either generator

Last Answer : Answer: D

Description : Regarding an AC generator connected to the main electrical bus; as the electric load and power factor vary, a corresponding change is reflected in the generator armature reaction. These changes in ... . governor speed droop setting B. voltage regulator C. balance coil D. phase-balance relay

Last Answer : Answer: B

Description : what is transient stability limit ?

Last Answer : The transient stability limit is the max power that can be transmitted by a machine to a fault or a receiving system during a transient state without loss of synchronism.The transient stability limit is always less than the steady state stability limit.

Description : What is transient state stability limit?

Last Answer : The transient state stability limit is the max. power that can be transmitted by a machine to a receiving system without loss of synchronism.In steady state the power transferred by synchronous machine is always less than the steady state stability limit.

Description : Define equal area criterion?

Last Answer : The equal area criterion for stability states that the system is stable if the area under pvs angle curve reduces to zero at some value of angle.

Description : Define critical clearing time and critiacal clearing angle

Last Answer : The critical clearing angle is the max. allowable change in the power angle before clearing the fault, without loss of synchronism. The critical clearing time can be defined as thw max. time delay that can be allowed to clear a fault without loss of synchronism.

Description : Define swing curve?

Last Answer : The swing curve is the plot between the power angle and time. It is usually plotted for a transient state to stydy the nature of variation in angle for a sudden large disturbance.

Description : What is steady state state stability limit?

Last Answer : The steady state stability limit is the max. power that can be transferred by a machine toa receving system without loss of synchronism.

Description : Define transient stability?

Last Answer : The transient stabilitymis defined as the abilitymof a system to remain stable for large disturbance.

Description : Define stability?

Last Answer : The stability of a system is defined as the ability of power system to return to stable operation when it is subjected to a disturbance. 68. Define steady state stability The stady statenstability is defined as the ability of a system to remain stable for small disturbance.

Description : What is meant by fault calculations

Last Answer : The fault condition of a power system can be dived into subtransient, transient and steady state periods. The currents in the various parts of the system and in the fault are different in ... for various types of faults at various locations in the system are commenly reffered as fault calculations.

Description : Name any two methods of reducing short circuit current/ By providing neutral reactance.

Last Answer : By introducing a large value of shunt reactance between buses.

Description : What is symmetrical and unsymmetrical fault?

Last Answer : The fault is called symmetrical fault if the fault current is equal in all the phases. The fault is called unsymmetrical fault if the fault current is not equal in all the phases.

Description : List the various types of series and shunt fault?

Last Answer : Shunt faults are, Line to ground fault line to line fault, double line to ground fault, three phase fault. Series faults are, One open conductor fault Two open conductor fault

Description : How are faults are classified?

Last Answer : The faults are classified as shunt and series faults. The shunt faults are due to short circuits in conductors and the series faults are due to oped conductors.

Description : What is meant by a fault?

Last Answer : A fault in a circuit is any failure which interferes with the normal flow of current. The faults are associated with abnormal change in current, voltage and frequency of the power systwm. The faults may ... to sence the faults to isolate the faulty part from the healthy part in the event of fault.