The starting torque is given as, Ts = K Im Is Sin Ф Where K = constant whose magnitude depends upon the design of the motor (i) The angle between Is and Im is small (approximately 25 degree) in a resistance split-phase induction motor, so the starting torque is small. (ii) Since currents Is and Im are not equal in magnitude, the rotating magnetic field is not uniform and the starting torque produced is small.