Which of the following statements is true concerning a polyphase synchronous propulsion motor? A. The motor is started as an induction motor. B. Resistance is gradually added to the rotor circuit. C. The starting current is held below the rated current. D. The field winding is energized for starting purposes only.

1 Answer

Answer :

Answer: A

Related questions

Description : A four pole, 60 Hz, three-phase synchronous motor comes up to 1760 RPM when started as an induction motor. What is the percent slip after the rotor field is energized? A. 0 B. 1.1 C. 2.2 D. 3.3

Last Answer : Answer: A

Description : In the illustrated device, the part labeled '1A' _________. EL-0001 A. are start and run windings for a single phase shaded pole induction motor B. is the stator for a polyphase induction ... armature for a squirrel cage rotor motor D. are direct current shunt field windings for a universal motor

Last Answer : Answer: B

Description : A characteristic of an induction motor with a low resistance rotor winding is _____________. A. high starting voltage B. high starting current C. high slippage D. low starting voltage

Last Answer : Answer: B

Description : In an AC synchronous motor electric propulsion plant, propeller speed is controlled by varying the _____________. A. prime mover speed B. electric coupling field strength C. number of energized main motor poles D. propulsion generator field strength

Last Answer : Answer: A

Description : The purpose of a cage rotor winding placed on the rotor of a synchronous motor is to _____________. A. provide excitation to the DC field B. start the machine as an induction motor C. contribute extra torque at synchronous speed D. prevent the machine from falling out of step

Last Answer : Answer: B

Description : While starting a main propulsion synchronous motor, the ammeter pegs out at maximum and then returns to the proper value after synchronization. This indicates the _____________. A. motor has started ... field windings are grounded C. slip rings are dirty D. power transmission cables are grounded

Last Answer : Answer: A

Description : A single-phase induction motor fails to start. The rotor is spun rapidly with the line switch closed. Having started by this method it is noted that the motor fluctuates between a very slow ... lies in the ______ A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : Which of the following types of motors is often designed for use in correcting power factor? A. Polyphase B. Wound-rotor C. Induction D. Synchronous

Last Answer : Answer: D

Description : A characteristic of a wound-rotor induction motor, with a high resistance rotor winding, is _____________. A. low starting torque B. high starting torque C. high speed D. low starting voltage

Last Answer : Answer: B

Description : The torque and current curves for a three-phase induction motor with a cage rotor, are shown in the illustration. Which of the following statements is true concerning the depicted curves? EL-0056 A. As slip ... D. If the motor is loaded to the point where 40% slip has resulted, it will stall.

Last Answer : Answer: D

Description : If an induction motor were to be operated at 90% rated voltage, _____________. A. there would be an increase in starting torque B. starting current would increase slightly C. synchronous speed would decrease slightly D. the slip would increase

Last Answer : Answer: D

Description : A single-phase induction motor will only start if you spin the rotor rapidly with the line switch closed. After starting, its speed fluctuates between very slow and half-speed. The problem ... in the ________. A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : Which statement is true concerning a split-phase induction motor? A. Motor rotation can be reversed without changing the windings or leads. B. Motor speed can be readily adjusted from zero to full ... proper wiring. D. Motor rotation can be reversed by reversing the leads on the starting winding.

Last Answer : Answer: D

Description : In the illustration, the assembly labeled 2 is a ________. EL-0001 A. wound rotor and shaft for a single phase induction motor B. conduction rotor and shaft for a polyphase induction motor C. ... cage rotor and shaft for a polyphase motor D. squirrel cage rotor for a single phase induction motor

Last Answer : Answer: C

Description : The speed of a three-phase squirrel-cage induction-type motor operating in a fixed frequency system is varied by changing the _____________. A. number of phases to the motor B. number of stator poles C. locked rotor current D. resistance of the rotor winding

Last Answer : Answer: B

Description : If the synchronous speed of a 12 pole, polyphase, induction motor operating at 60 Hz were 600 RPM, how many poles will be required in a similar motor operating at the same frequency but having a synchronous speed of 900 RPM? A. 4 B. 6 C. 8 D. 18

Last Answer : Answer: C

Description : The synchronous speed of an induction motor is the ________. A. speed at which the rotor turns B. speed of the rotating field C. frequency of the rotor current D. slip in per cent of rotor RPM

Last Answer : Answer: B

Description : A single-phase induction motor starts, comes up to about 75% rated speed, slows down to a lower speed, and accelerates again. The problem is most likely in the ____________. A. starting winding B. running winding C. starting capacitor D. running centrifugal switch

Last Answer : Answer: B

Description : If the centrifugal switch or relay used for cutting out the starting winding of a split-phase induction motor fails to open once the motor is in operation, the _____________. A. motor will overspeed B ... C. motor will immediately stall under load D. motor torque will be above normal at rated speed

Last Answer : Answer: B

Description : When starting a DC propulsion motor the variable rheostat must FIRST be turned ____________. A. all the way to the run position then quickly back to slow B. to the slow position then gradually moved to full speed C. to the mid position D. quickly to the run position

Last Answer : Answer: B

Description : Which of the following statements is true concerning the operating characteristics of a squirrel-cage motor? A. Rotor slip is dependent upon the motor load. B. An increase in motor load results in ... results in less generated current. D. A decrease in rotor speed produces a weaker magnetic field.

Last Answer : Answer: A

Description : The speed of a wound-rotor induction motor _____________. A. will be fixed by the number of field poles B. can be varied by a rheostat-type control C. can only be synchronous speed at full load D. can only attain synchronous speed at no load

Last Answer : Answer: B

Description : Autotransformer starters or compensators are sometimes used with polyphase induction motors to _____________. A. reduce the voltage applied to the motor during the starting period B. increase the voltage for ' ... to be either stepped up or down, depending on the application, to ensure full torque

Last Answer : Answer: A

Description : The speed of a squirrel-cage induction motor is determined by the ____________. A. diameter of the stator B. number of stator poles C. rotor winding resistance D. rotor conducting bars resistance

Last Answer : Answer: B

Description : The speed of a squirrel cage induction motor is determined by the _____________. A. diameter of the stator B. number of stator poles C. rotor winding resistance D. bar resistance of the conducting rotor

Last Answer : Answer: B

Description : A motor using a rheostat in the motor circuit to vary the speed is called a ____________. A. squirrel-cage induction motor B. regenerative braking motor C. wound-rotor induction motor D. synchronous motor

Last Answer : Answer: C

Description : Under normal conditions, the speed of a two-speed squirrel cage induction motor is changed by varying the ____________. A. frequency of the applied voltage B. resistance in the rotor circuit C. number of field poles D. amplitude of the applied voltage

Last Answer : Answer: C

Description : A single-phase induction motor having a relatively high starting torque, is the ___________. A. shaded pole motor B. wound-rotor motor C. capacitor-start motor D. resistance-start motor

Last Answer : Answer: C

Description : The purpose of amortisseur windings in a synchronous motor is to ______________. A. reduce eddy current losses B. produce a higher power factor C. provide a means for starting D. eliminate arcing between the stator and the rotor

Last Answer : Answer: C

Description : Amortisseur windings are installed in a synchronous motor to _____________. A. reduce eddy current losses B. produce a higher power factor C. provide a means for starting D. eliminate arcing between the stator and the rotor

Last Answer : Answer: C

Description : How the starting winding produce rotation in a single phase resistance start induction motor?

Last Answer : The starting winding is highly resistive and the main winding is inductive. So the phase difference between the two currents becomes nearly 90 degree and hence the motor start as two phase motor.

Description : In a 15 HP induction-type motor with a cage rotor, the current required at standstill to produce starting torque is approximately ____________. A. half the full load current B. equal to the full load current C. five times the full load current D. ten to twenty times the full load current

Last Answer : Answer: C

Description : The propeller shaft speed in a turbo-electric, synchronous, propulsion drive motor is changed by varying the __________. A. turbine speed B. number of motor poles C. field strength of the generator D. field strength of the motor

Last Answer : Answer: A

Description : If the residual flux is absent in the rotor iron of the isolated induction generator, a) it will not run. b) it will run as induction motor c) it will burn the winding d) it will not affect the characteristic of the generator

Last Answer : Ans: A

Description : A split-phase induction squirrel-cage motor will not come up to speed, even though the rated voltage, rated frequency, and rated load are applied. The suspected trouble could be due to _____________. A. a faulty centrifugal switch B. broken rotor bars C. worn bearings D. all of the above

Last Answer : Answer: D

Description : A 3-phase, 400 votts, 50 Hz, 100 KW, 4 pole squirrel cage induction motor with a rated slip of 2% will have a rotor speed of (A) 1500 rpm (B) 1470 rpm (C) 1530 rpm (D) 1570 rpm

Last Answer : Ans: B N = NS (1-S) and NS =120 f / p =120 x 50 /4 = 1500 rpm ∴N= 1500 (1-0.02) =1470 rpm

Description : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m.

Last Answer : (D) 75 r.p.m.

Description : In general, polyphase induction motors can be started on full line voltage by means of ______________. A. compensator starters B. autotransformer starters C. across-the-line starters D. primary-resistor starters

Last Answer : Answer: C

Description : Low horsepower, polyphase, induction motors can be started with full voltage by means of _____________. A. compensator starters B. autotransformer starters C. across-the-line starters D. primary-resistor starters

Last Answer : Answer: C

Description : The synchronous speed for a 3 phase 6-pole induction motor is 1200 rpm. If the number of poles is now reduced to 4 with the frequency remaining constant, the rotor speed with a slip of 5% will be _________. (A) 1690 rpm (B) 1750 rpm (C) 1500 rpm (D) 1710 rpm

Last Answer : (D) 1710 rpm

Description : A motor which can conveniently be operated at lagging as well as leading power factors is the (A) squirrel cage induction motor. (B) wound rotor induction motor. (C) synchronous motor. (D) DC shunt motor.

Last Answer : (C) synchronous motor.

Description : Which motor has high Starting Torque and Staring current DC motor, Induction motor or Synchronous motor?

Last Answer : DC Series motor has high starting torque. We can not start the Induction motor and Synchronous motors on load, but can not start the DC series motor without load.

Description : Which Motor Has High Starting Torque And Staring Current Dc Motor, Induction Motor Or Synchronous Motor?

Last Answer : DC Series motor has high starting torque. We can not start the Induction motor and Synchronous motors on load, but can not start the DC series motor without load.

Description : The speed of a squirrel-cage, multi-speed, induction motor, as used aboard ship, is varied by changing the __________. A. number of connected poles in the stator B. frequency to the motor C. excitation voltage D. resistance of the rotor circuit

Last Answer : Answer: A

Description : A degree of control over the speed of a slip ring induction motor can be obtained by _____________. A. adjusting governor linkage B. changing the number of phases to the motor C. inserting resistance into the stator circuit D. inserting resistance into the rotor circuit

Last Answer : Answer: D

Description : The variable resistance placed in the rotor circuit of a wound-rotor induction motor provides for __________. A. speed control B. frequency control C. voltage control D. use as a split-phase motor

Last Answer : Answer: A

Description : The rotor of a synchronous motor operates in synchronism with the rotating field because ______________. A. of the amortisseur windings B. the rotor is magnetically locked into step with the ... field strength varies directly with rotor slip D. the stator flux rotates in the opposite direction

Last Answer : Answer: B

Description : A synchronous motor maintains synchronism with the rotating field because _____________. A. field strength varies directly with rotor slip B. DC current applied to the rotor coils causes the rotor ... the flux created by the excitation current D. the stator flux rotates in the opposite direction

Last Answer : Answer: B

Description : If a single-phase induction motor fails to start, the problem may be _____________. A. an open in the main winding B. a shorted shunt field C. a closed centrifugal switch D. low circuit frequency

Last Answer : Answer: A

Description : If a single-phase induction motor fails to start, the problem may be _____________. A. an open in the run winding B. a shorted shunt field C. a closed centrifugal switch D. low circuit frequency

Last Answer : Answer: A