Description : The purpose of the commutator and brushes on a DC generator is to _____________. A. transfer generated direct current voltage from the armature to the line B. convert the alternating voltage ... contact method to excite the field D. reduce sparking between the armature and the carbon brushes
Last Answer : Answer: B
Description : Which of the following are the parts of a DC generator that convert the AC in the armature to DC in the external circuit. Are these parts the: w) field poles x) slip rings and the brushes y) commutator and the brushes z) armature and the core
Last Answer : ANSWER: Y -- COMMUTATOR AND THE BRUSHES
Description : A shunt-wound DC generator is one in which the shunt field windings are in parallel with the _____________. A. commutator B. brushes C. armature D. all of the above
Last Answer : Answer: D
Description : A short circuit in the armature of a DC motor will cause the motor to _____________. A. run fast B. hum when energized C. spark at the brushes D. fail to start
Last Answer : Answer: C
Description : A DC generator is used to supply direct current in order to maintain an AC generator field and is known as a/an _____________. A. rotor B. stator C. exciter D. armature
Description : If an AC generator experiences voltage failure, the cause may be _____________. A. an open in the field circuit B. the brushes shifting out of the neutral plane C. excessive locked-rotor current D. a rotating slip ring
Last Answer : Answer: A
Description : An AC generator operating in parallel loses its excitation without tripping the circuit breaker. This will __________. A. not affect the faulty generator due to the compensation of the other generators B. ... between the armature and the bus D. cause high currents to be induced in the field windings
Description : Which of the following components are used to convert alternating current produced in the generator windings to direct current? A. Armature and equalizer B. Commutator and brushes C. Rotor and interpoles D. Field and exciter
Description : Hysteresis in a direct current generator is indicated by _____________. A. arcing at the brushes B. pulsating terminal current C. heating of the armature core D. hunting and over control
Description : The most common source of excitation for synchronous motors is a/an _____________. A. low voltage battery B. motor attenuator set C. DC exciter generator D. AC supply
Description : A loss of field excitation to an AC generator while operating in parallel will cause it to ____________. A. absorb more and more load due to decreased armature reaction B. lose its load due to ... polarity D. lose its load, begin to motorize, trip out on reverse power relay, and possibly overspeed
Description : The voltage output of an AC generator is accurately controlled by _____________. A. changing the sensitivity of the prime mover to large changes in voltage B. varying the reluctance of the air gap C. varying the DC exciter voltage D. shorting out part of the armature windings
Description : On some diesel-electric ships, the DC propulsion motor will only attain half speed when the generator fields are fully excited. Speeds above this are obtained by _____________. A. rotating brush ... B. raising the generator engine speed C. lowering the generator engine speed D. decreasing excitation
Description : Brushes in a generator must be positioned in the neutral plane to avoid sparking between the brushes and the _____________. A. yoke B. armature windings C. field pole windings D. commutator
Description : A shorted armature coil in a DC motor can be detected by _____________. A. sparking at the brushes B. shiny armature coil C. worn grooves in the armature D. undercut mica
Description : Temporary repairs to an open DC propulsion armature coil can be made by _____________. A. connecting the coil ends directly to a pair of negative brushes B. disconnecting coil ends, insulating ... C. grounding the coil ends and short circuiting the commutator bar D. removing the sparking brushes
Description : If you reverse both the field and the armature connections to a DC propulsion motor, _____________. A. the direction of motor rotation will change B. the brushes will become overheated C. a magnetic lock will occur in the motor D. the direction of motor rotation will remain the same
Description : The purpose of a cage rotor winding placed on the rotor of a synchronous motor is to _____________. A. provide excitation to the DC field B. start the machine as an induction motor C. contribute extra torque at synchronous speed D. prevent the machine from falling out of step
Description : In an AC generator, direct current from a separate source is passed through the windings of the rotor _____________. A. by means of slip rings and brushes B. by means of a commutator C. by means of rotating bar magnet D. to minimize the danger of arc over
Description : Armature cores in a DC generator are made of laminated steel sheets to _____________. A. fit the curvature of the frame B. increase the hysteresis effect C. reduce eddy current losses D. allow for easy assembly
Description : Which of the listed conditions might contribute to very rapid wearing of a DC machine's commutator bars? A. A grounded commutator bar B. Using improper carbon brushes C. Aligning the front and rear mica V-rings improperly D. An open circuit in the armature
Description : In an induction motor, rotor currents are circulated in the rotor by _____________. A. slip rings and brushes B. an armature and brushes C. inductive reaction of the rotating stator field D. external variable resistors
Description : Coast Guard Regulations (46 CFR) require that each alternating current generator arranged for parallel operation shall be provided with _____________. A. more than one means of excitation B. individual circuit fuses C. a high back-pressure trip D. a reverse-power trip
Description : A transformer in an electric circuit serves to ____________. A. generate its own electrical power B. transform electrical energy into mechanical energy C. increase or decrease circuit voltage as required D. convert AC current to DC current
Description : Automatic voltage regulators provided on switchboards function to _____________. A. regulate the AC load on the generator B. protect the switchboard from high voltage C. govern prime mover speed to control voltage D. vary the field excitation to the generators
Description : The power factor at which a paralleled AC generator operates is usually adjusted by the _____________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage
Description : Which of the listed conditions will occur if the polarity of the field poles and the direction of current to the brushes of a DC motor were both reversed? A. The motor would not start. ... direction of rotation of the armature would be unchanged. D. The field pole windings would become overheated.
Description : Which of the following statements describes what will happen when both the polarity of the field poles, and the direction of current to the brushes of a DC motor are reversed? A. The motor will ... of rotation of the armature will remain the same. D. The field pole windings will become overheated.
Description : The function of the commutator in a DC motor is to ________. A. reverse the flow of current through the armature B. reverse the flow of current in the field poles C. reduce the reluctance of the magnetic path through the motor D. shift the neutral running plane of the brushes to prevent sparking
Description : Regarding an AC generator connected to the main electrical bus; as the electric load and power factor vary, a corresponding change is reflected in the generator armature reaction. These changes in ... . governor speed droop setting B. voltage regulator C. balance coil D. phase-balance relay
Description : The voltage developed by an AC generator is controlled by varying the ____________. A. speed of the prime mover B. AC excitation to the field C. DC excitation to the field D. DC excitation of the voltage regulator
Description : Moisture accumulating in electric motors and generator windings having a cold insulation resistance greater than 50,000 ohms may be baked out with internal heat. This heat can be developed by ____________. ... an electric welder and feeding it into the armature while running the motor at full speed
Description : Moving the rheostat handle shown in the illustration, that is used to control a DC generator, towards the 'raise' direction will increase the _____________. EL-0030 A. field resistance B. armature resistance C. armature speed D. line voltage
Description : If the connections for the field and the armature on a DC motor are reversed, _____________. A. the motor will run as a generator B. the motor will not run C. the direction of rotation will be the same D. the direction of rotation will be reversed
Description : DC generator voltage is decreased by cutting _____________. A. in field resistance B. out field resistance C. in armature resistance D. out armature resistance
Description : A flickering ground detection lamp on a DC system would indicate a _____________. A. multiple-ground condition in the distribution system B. ground in an armature coil of an operating machine C. ground in a motor accompanied with a short D. short between two adjacent bars of the generator commutator
Description : A DC shunt generator has its field windings connected in _____________. A. series with the series windings B. parallel with the field rheostat C. series with the armature windings D. parallel with the armature windings
Description : The most common type of AC service generator found aboard ship is the stationary _____________. A. electromagnetic field, revolving armature type B. electromagnetic field, oscillatory armature type C. armature, oscillatory electromagnet field type D. armature, rotating electromagnetic field type
Description : The output voltage of a three-phase alternator is regulated by the _____________. A. AC voltage to the armature B. AC voltage to the field C. DC voltage to the armature D. DC voltage to the field
Description : An alternator will fail to produce line voltage as a result of _____________. A. a closed circuit breaker B. oxidized slip rings C. improperly staggered brushes D. exciter generator failure
Description : As shown in the illustration, the circuit has been on the line for several days when component 'E1' burns out. The operator receives an alarm, switches over 'B' to energize the standby ... than required for the circuit therefore limiting the current through the alarm relay which will not pick up
Description : In a diesel electric plant, raising the generator's field excitation will cause the DC propulsion motor to ________. A. increase in speed B. decrease in speed C. affect generator speed only D. affect main motor speed if done in conjunction with higher generator engine speeds
Description : The main purpose of an electric space heater installed in a large AC generator is to _____________. A. keep the lube oil warm for quick starting B. prevent moisture from condensing in the ... is shutdown C. prevent the windings from becoming brittle D. prevent acidic pitting of the slip rings
Description : The main purpose of an electric space heater installed in a large AC generator is to _____________. A. prevent the windings from becoming brittle B. prevent moisture from condensing in the windings during ... C. prevent acidic pitting of the slip rings D. keep the lube oil warm for quick starting
Description : When securing an AC generator, you should FIRST ___________. A. open the generator circuit breaker B. switch the voltage regulator to 'manual' C. decrease the field excitation to minimum D. reduce the load on the unit
Description : An open armature connection in a DC propulsion motor could be caused by ____________. A. low-load operation B. clogged ventilation ducts C. sparking at the brushes D. a grounded shunt field coil
Description : A synchronous motor maintains synchronism with the rotating field because _____________. A. field strength varies directly with rotor slip B. DC current applied to the rotor coils causes the rotor ... the flux created by the excitation current D. the stator flux rotates in the opposite direction
Description : Which of the following statements is true concerning all three-phase alternators? A. Each has three separate but identical armature windings acted on by one system of rotating magnets. B. Each has one ... The three phases always provide power to the load through three sets of slip rings and brushes.
Description : Three factors responsible for the change in voltage as load is applied to an AC generator are: 1) the drop in resistance in the armature circuit, 2) the change in flux, and 3) the ____________. A. armature winding speed B. inductance load drop C. coil pitch factor D. armature reactance voltage drop
Description : Universal motors will operate on AC or DC current, and are generally found in _____________. A. portable tools B. large pump motors C. turbo electric main motors D. forced draft fans