Description : The presence of these pollutants can cause a series of problems. The main problems that are caused______ • are fouling, • limestone formation, • corrosion and biological • All of the above
Last Answer : All of the above
Description : In cooling tower ,higher temperature __________ corrosion potential • Decrease • Increase • Temperature has no effect on corrosion
Last Answer : Increase
Description : What are present depend on cooling tower building material as well 1 pollution 2 population 3 dust 4 none of these
Last Answer : 1 pollution
Description : The part of a nuclear power plant that prevents thermal pollution of lakes or rivers is the: w) reactor x) coolant/moderator y) cooling tower z) control rod
Last Answer : ANSWER: Y -- COOLING TOWER
Description : In a gas-liquid shell and tube heat exchanger, the (A) Presence of a non-condensable gas decreases the condensing film coefficient (B) Gases under high pressure are routed through the tube side, because high pressure ... water or steam condensate remain localised to the tubes (D) All 'a', 'b' & 'c'
Last Answer : (D) All 'a', 'b' & 'c'
Description : In hyperboloid cooling towers the material is filled at 1. Tower’s bottom 2. Tower’s top 3. Near tower 4. None of above
Last Answer : Tower’s top
Description : Which among the following are the components of natural draft cooling tower a) Supply basin b) reinforced concrete c) Hot water distribution d) none of the above
Last Answer : reinforced concrete
Description : In the natural draft cooling tower_________ is not required a) Fan b) tower c) Nozzle d) none of the above
Last Answer : Fan
Description : In natural draft cooling tower the air flow is obtained by___________ a) Difference in air pressure b) difference in air temperature c) Difference in air speed d) none of the above
Last Answer : Difference in air pressure
Description : Cooling tower is a ______device a) Heat absorption b) heat rejection c) Both a and b c) neither a nor b
Last Answer : heat rejection
Description : The ratio of dissolved solids in circulating water to the dissolved solids in makeup water is called a) Liquid gas ratio b) Cycle of concentration c) Cooling tower effectiveness d) None of the above
Last Answer : Cycle of concentration
Description : Which one of the following is true to estimate the range of cooling tower? a) Range = cooling water inlet temperature - wet bulb temperature b) Range = cooling water outlet temperature - wet bulb temperature ... = heat load in kcal per hour / water circulation in lines per hour d) None of the above
Last Answer : Range = heat load in kcal per hour / water circulation in lines per hour
Description : Cooling tower effectiveness is the ratio of a) Range/( Range + approach) b) Approach/(range + approach) c) Range /(range - approach) d) Approach/ /(range - approach)
Last Answer : Range/( Range + approach)
Description : Natural draft cooling tower are mainly used in a) Steel Industry b) Alumina industry c) Fertilizer industry d) Power station
Last Answer : Power station
Description : How is air produced in mechanical draught cooling tower? a) Air Tuyeres b) Propeller fans c) Air blowers d) Louvre
Last Answer : Propeller fans
Description : In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower
Last Answer : Atmospheric cooling tower
Description : Which of the following is the simplest method of cooling the condenser water? • Spray cooling pond • Cooling tower • Indirect air cooling • Hyperbolic cooling tower
Last Answer : Spray cooling pond
Description : In which system is Cooling of hot water is done on tray as step by? a. Mechanical draught cooling system b. Hyperbolic cooling tower c. Atmospheric cooling tower d. Wet cooling tower
Description : The first hyperbolic cooling tower was built in... a. 1916 b. 1917 c. 1918 d. 1919
Last Answer : 1918
Description : Normally the guaranteed best approach a cooling tower can achieve is _____. • 5°C • 12°C • 8°C • 2.8°C
Last Answer : 2.8°C
Description : L/G ratio in a cooling tower is a ratio of _____. • Length and girth • Length and temperature gradient • Water flow rate and air mass flow rate • Air mass flow rate and water flow rate
Last Answer : Water flow rate and air mass flow rate
Description : The ratio of dissolved solids in circulating water to dissolved solids in makeup water is called. • Liquid gas ratio • Cycle of concentration • Cooling tower effectiveness • None of the above
Description : Cooling tower effectiveness is the ratio of _____. • Range/(range + approach) • Approach/(range + approach) • Range/ Approach • Approach/ Range
Last Answer : Range/(range + approach)
Description : A better indicators for cooling tower performance is _____. • Wet bulb temperature • Dry bulb temperature • Range • Approach
Last Answer : Approach
Description : The ……….-induced response of cooling tower is the key factor to improve safety and to reduce tower crack. a) wind c) heat b) water d) steam
Last Answer : wind
Description : Cooling efficiency of a cooling tower is significantly affected under cross-wind condition and might decrease to……… in the range of moderate to high wind velocity condition. a) 50% c) 25% b) 75% d) 90%
Last Answer : 75%
Description : The first hyperboloid shaped cooling tower was introduced by the Dutch engineers Frederik van Iterson andGerard Kuypers and built in ……….. a) 1918 c) 1919 b) 1870 d) 1920
Description : . In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower
Description : Which of the following faction affect the cooling tower performance? • The range • Heat load • Wet bulb temperature • All of the above
Description : In ________ cooling tower there is no direct contact between the water and Air. • Dry type • Evaporative type • Once through • All of the above
Description : When sizing a cooling tower the highest anticipate__________ should be used? • Dry bulb • Wet bulb • Both dry and wet bulb • None of the above
Last Answer : Wet bulb
Description : The pollutants that are present depend on __________ building material, as well. • Cooling tower • Water tower • Steam tower • Fire tower
Last Answer : cooling water
Description : How do you service a cooling tower? • Ensure Proper Airflow. . Clean Your Tubes. • Inspect the Water Pump. • All of above
Last Answer : all of above
Description : . How can we increase the efficiency of a cooling tower? a. Save energy. b. Reduce the amount of water being consumed. c. Decrease the amount of chemicals required for water treatment. d. All of above
Last Answer : All of above
Description : A ______ is a specialized heat exchanger in which air and water are brought into direct contact with each otherin order to reduce the water's temperature. a. Cooling tower b. Heating tower c. Both d. All are wrong
Last Answer : cooling tower
Description : How do you service a cooling tower? • Ensure Proper Airflow. Clean Your Tubes. • Inspect the Water Pump. • All of above
Description : How can we increase the efficiency of a cooling tower? a. Save energy. b. Reduce the amount of water being consumed. c. Decrease the amount of chemicals required for water treatment. d. All of above
Last Answer : d. All of above
Description : Noise produced by cooling fans (employed in air cooled heat exchangers or cooling tower) is mainly caused due to the turbulence created by blade passage through air. It can be reduced by use of a slower fan (A) With greater ... (B) Of increased diameter (C) Both (A) & (B) (D) Neither (A) nor (B)
Last Answer : (C) Both (A) & (B)
Description : Caves are frequently associated with a certain kin of topography that includes sinkholes, disappearing streams and many limestone outcrops. With which of the following topographies are such features related? w) arid topography x) valley and ridge topography y) Karst topography z) none of these
Last Answer : ANSWER: Y -- KARST TOPOGRAPHY
Description : The outlet temperature of cooling water in a heat exchanger is generally not allowed to exceed above 50°C in industrial practice mainly to avoid (A) Its evaporation loss (B) Excessive corrosion (C) Uneconomic LMTD (D) Decrease in heat exchanger efficiency
Last Answer : (B) Excessive corrosion
Description : During the absorption of HCl gas in water (to produce liquid HCl), the gas is kept above dew point to (A) Increase the rate of absorption (B) Avoid corrosion (C) Reduce the cooling water circulation rate (D) None of these
Last Answer : (B) Avoid corrosion
Description : Differentiate induced draft and forced draft cooling towers based on (i) Location of fan (ii) Corrosion of blades (iii) Efficiency (iv) Fan size
Last Answer : Differentiate induced draft and forced draft cooling towers based on (i) Location of fan (ii) Corrosion of blades (iii) Efficiency (iv) Fan size
Description : Is formation of limestone a physical or chemical change?
Last Answer : I am not sure but I think it is Physical change.
Description : When limestone is subjected to high temperature and pressure known as Metamorphism, it results in the formation of? a. Granite b. Quicklime c. Sandstone d. Marble
Last Answer : d. Marble
Description : The aquifer of a famous artesian formation in the Great Plains is a layer of rock called the: w) Clinton limestone x) Dakota sandstone y) Pierre shale z) Vermont marble
Last Answer : ANSWER: X -- DAKOTA SANDSTONE
Description : The cooling tower uses the phenomenon of evaporative cooling to cool warm water above the dbt of air. A. true B. false
Last Answer : ANSWER : B
Description : The equipment frequently used for adiabatic humidification-cooling operation with recirculating liquid is (A) Natural draft cooling tower (B) Induced draft cooling tower (C) Spray chamber (D) None of these
Last Answer : (C) Spray chamber
Description : When the temperature and humidity of air is low, we usually use __________ draft cooling tower. (A) Natural (B) Forced (C) Induced (D) None of these
Last Answer : (A) Natural
Description : Make up water is supplied during cooling tower operation to compensate for water losses due to (A) Evaporation (B) Blowdown (C) Entrainment (D) All (A), (B) & (C)
Last Answer : (D) All (A), (B) & (C)
Description : Heat load in a cooling tower (A) Means the amount of heat thrown away (KCal/hr.) by the cooling tower (B) Is equal to the number of kg, of water circulated times the cooling range (C) Both (A) & (B) (D) Neither (A) nor (B)