If the conductive loop on the rotor of a simple two -pole, single-phase generator rotates at the rate of 400 rps. The frequency of the induced output voltage will be: A. 40 Hz B. 100 Hz C. 400 Hz D. indeterminable

1 Answer

Answer :

If the conductive loop on the rotor of a simple two -pole, single-phase generator rotates at the rate of 400 rps. The frequency of the induced output voltage will be: 400 Hz

Related questions

Description : If the driving torque, such as that produced by a diesel engine, creates pulsations when coupled with a synchronous generator operating in parallel; the generator rotor may be periodically pulled ahead or behind ... as it rotates. This co A. hunting B. direct coupling C. peaking D. harmonic coupling

Last Answer : Answer: A

Description : If the driving torque, such as that produced by a diesel engine, creates pulsations when coupled with a synchronous generator operating in parallel; the generator rotor may be periodically pulled ... windings B. direct coupling C. increase governor speed droop D. decreasing governor speed droop

Last Answer : Answer: A

Description : In the illustrated device, the part labeled '1A' _________. EL-0001 A. are start and run windings for a single phase shaded pole induction motor B. is the stator for a polyphase induction ... armature for a squirrel cage rotor motor D. are direct current shunt field windings for a universal motor

Last Answer : Answer: B

Description : A single-phase induction motor having a relatively high starting torque, is the ___________. A. shaded pole motor B. wound-rotor motor C. capacitor-start motor D. resistance-start motor

Last Answer : Answer: C

Description : In the diagram shown below, if rotor X and rotor Z rotate in same direction and rotor Y rotates in opposite direction, then specify the type of node vibration. A. Three node vibration B. Two node vibration C. Single node vibration D. None of the above

Last Answer : B. Two node vibration

Description : In the diagram shown below, if rotor X and rotor Z rotate in same direction and rotor Y rotates in opposite direction, then specify the type of node vibration. A. Three node vibration B. Two node vibration C. Single node vibration D. None of the above

Last Answer : B. Two node vibration

Description : In the diagram shown below, if rotor X and rotor Z rotate in same direction and rotor Y rotates in opposite direction, then specify the no of degree of freedom vibration.a. Three degree of freedom vibration b. Two degree of freedom vibration c. Single degree of freedom vibration d. None of the above

Last Answer : b. Two degree of freedom vibration

Description : The power input to the rotor of a 400V, 50 Hz 6 pole three phase induction motor is 20kW. The slip is 3%. The frequency of rotor currents is: (A) 1 Hz (B) 1.5 Hz (C) 2 Hz (D) 1 2 Hz

Last Answer : C

Description : A 6 pole 3-phase wound-rotor induction machine is driven by another machine at 1800 rpm. The rotor of the induction machine is connected to a 50Hz system. If the mechanical rotation of the rotor is in the same direction as the rotor winding flux rotation, then frequency of the stator voltage will be

Last Answer : A 6 pole 3-phase wound-rotor induction machine is driven by another machine at 1800 rpm. The rotor of the induction machine is connected to a 50Hz system. If the mechanical rotation of ... the same direction as the rotor winding flux rotation, then frequency of the stator voltage will be 140 Hz.

Description : Explain how sinusoidal AC voltage is generated by using simple one loop generator.

Last Answer : An electric current produced by means of electrical machine is known as generator which converts mechanical energy into electrical energy. When conductor cuts the magnetic flux, emf induced in it. (Faraday' ... upon position of armature. The nature of emf is alternating as shown by the waveform. 

Description : A four pole, 60 Hz, three-phase synchronous motor comes up to 1760 RPM when started as an induction motor. What is the percent slip after the rotor field is energized? A. 0 B. 1.1 C. 2.2 D. 3.3

Last Answer : Answer: A

Description : What type of rotor is used in split-phase motors? A. Drum B. Salient pole C. Squirrel-cage D. Wound-rotor

Last Answer : Answer: C

Description : A 1.8°step, 4-phase stepper motor has a total of 40 teeth on 8 pole of stator. The number of rotor teeth for their rotor will be (A) 40 (B) 50 (C) 100 (D) 80

Last Answer : (B) 50

Description : A 3-phase, 400 votts, 50 Hz, 100 KW, 4 pole squirrel cage induction motor with a rated slip of 2% will have a rotor speed of (A) 1500 rpm (B) 1470 rpm (C) 1530 rpm (D) 1570 rpm

Last Answer : Ans: B N = NS (1-S) and NS =120 f / p =120 x 50 /4 = 1500 rpm ∴N= 1500 (1-0.02) =1470 rpm

Description : The synchronous speed for a 3 phase 6-pole induction motor is 1200 rpm. If the number of poles is now reduced to 4 with the frequency remaining constant, the rotor speed with a slip of 5% will be _________. (A) 1690 rpm (B) 1750 rpm (C) 1500 rpm (D) 1710 rpm

Last Answer : (D) 1710 rpm

Description : The rotor frequency for a 3 phase 1000 RPM 6 pole induction motor with a slip of 0.04 is________Hz (A) 8 (B) 4 (C) 6 (D) 2

Last Answer : Ans: D Given: N=1000 rpm ; P= 6; s= 0.04; and f = NP/ 120 = 10006/120 = 50 Hz Rotor frequency fr=sf = 0.0450 = 2.0 Hz

Description : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m.

Last Answer : (D) 75 r.p.m.

Description : The frequency of the rotor current in a 3 phase 50 Hz, 4 pole induction motor at full load speed is about (A) 50 Hz. (B) 20 Hz. (C) 2 Hz. (D) Zero.

Last Answer : (C) 2 Hz.

Description : Explain speed control method of 3 phase induction motor by the following methods: (1) Pole changing (2) Rotor resistance control (3) Stator voltage

Last Answer : 1) Pole Changing Method:  Synchronous speed is given by, From the above equation of synchronous speed, it can be seen that synchronous speed (and hence, running speed) can ... in voltage and consequently the speed decreases and vice versa. Ultimately speed depends on the supply voltage.

Description : The rotor frequency for a 3-phase 6-pole, 1000 r.p.m. induction motor with a slip of 0.04 is (a) 2 Hz (b) 4 Hz (c) 6 Hz (d) 8 Hz  

Last Answer : 2hz is rotor frequency

Description : If a 3-phase, 400V, 50Hz, 4 pole induction motor is running at a slip of 5% then the relative speed of rotor field with respect to stator filed is:

Last Answer : If a 3-phase, 400V, 50Hz, 4 pole induction motor is running at a slip of 5% then the relative speed of rotor field with respect to stator filed is: zero

Description : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor ... Hz supply is  (A) 58.5 A (B) 45.0 A (C) 42.7 A (D) 55.6 A

Last Answer : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is 45.0 A 

Description : A 3-phase, 4-pole, 50Hz induction motor runs at a speed of 1440 rpm. The rotating field produced by the rotor rotates at a speed of ________ rpm with respect to stator field. (A) 1500 (B) 0 (C) 1440 (D) 60

Last Answer : 0

Description : An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is (A) 5.06 kW (B) 0.3 kW (C) 100 kW (D) 83.33 kW

Last Answer : An 8-pole, 50Hz, three-phase induction motor is running at 705rpm and has a rotor copper loss of 5kW. Its rotor input is 83.33 kW

Description : The rotor of a synchronous motor operates in synchronism with the rotating field because ______________. A. of the amortisseur windings B. the rotor is magnetically locked into step with the ... field strength varies directly with rotor slip D. the stator flux rotates in the opposite direction

Last Answer : Answer: B

Description : A synchronous motor maintains synchronism with the rotating field because _____________. A. field strength varies directly with rotor slip B. DC current applied to the rotor coils causes the rotor ... the flux created by the excitation current D. the stator flux rotates in the opposite direction

Last Answer : Answer: B

Description : In Induction motor Slip frequency of rotor current, when rotor speed is Nr. Then rotor producing slip field rotates with respect to stator is a) Slip frequency b) Nr c) Ns d) None

Last Answer : Ans: Ns

Description : If stator field is rotating in clockwise direction rotor rotates in (A) any direction (B) cannot predict (C) anticlockwise (D) clockwise 

Last Answer : If stator field is rotating in clockwise direction rotor rotates in clockwise 

Description : An electric motor in which both stator field and rotor rotates with same speed is called?

Last Answer : An electric motor in which both stator field and rotor rotates with same speed is called synchronous motor.

Description : The pole star does not seem to move because (a) it is in line with the earth’s axis of rotation (b) it moves around the sun and not the earth (c) its movement can be seen only during a solar eclipse (d) it rotates very rapidly

Last Answer : Ans:(a)

Description : A 4 pole lap wound dc shunt motor rotates at the speed of 1500 rpm, has a flux of 0.4 mWb and the total number of conductors are 1000. What is the value of emf? (A) 100 Volts. (B) 0.1 Volts. (C) 1 Volts. (D) 10 Volts.

Last Answer : Ans: D Given N = 1500 rpm, Φ = 0.4 mWb, Z = 1000, P = 4, & A= 4 Therefore, Eb = NΦPZ / 60 A = 1500 x 0.4 x 4 x 1000 x 10^-3 / 60 x 4 = 60/6 = 10 volts

Description : A 8 pole alternator rotates at 750 r.p.m. Its frequency is

Last Answer : A 8 pole alternator rotates at 750 r.p.m. Its frequency is 50 Hz

Description : A centre zero ammeters connected in the rotor circuit of a 6-pole 50 Hz induction motor makes 30 oscillations in one minute. The rotor speed is

Last Answer : A centre zero ammeters connected in the rotor circuit of a 6-pole 50 Hz induction motor makes 30 oscillations in one minute. The rotor speed is 990.

Last Answer : The stator and rotor pole number may be different in a Reluctance motor.

Description : What will be the frequency of a three-phase, six pole, AC generator operating at 1800 revolutions per minute? A. 60 hertz B. 90 hertz C. 120 hertz D. 180 hertz

Last Answer : Answer: B

Description : What will be the phase angle relationship of a six-pole, three-phase, rotating field generator? A. 60° B. 120° C. 180° D. 360°

Last Answer : Answer: B

Description : A 100 MVA, 11 KV, 3-phase, 50 Hz, 8—pole synchronous generator has an inertia constant H equal to 4 seconds. The stored energy in the rotor of the generator at synchronous speed will be  A) 100 MJ B) 400 MJ C) 800 MJ D) 12.5 MJ

Last Answer : 800

Description : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Last Answer : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Description : The generator which gives dc supply to the rotor is called:  (1) Converter (2) Exciter (3) Inverter (4) Rectifier

Last Answer : The generator which gives dc supply to the rotor is called: Exciter.

Description : A single-phase induction motor will only start if you spin the rotor rapidly with the line switch closed. After starting, its speed fluctuates between very slow and half-speed. The problem ... in the ________. A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : A single-phase induction motor fails to start. The rotor is spun rapidly with the line switch closed. Having started by this method it is noted that the motor fluctuates between a very slow ... lies in the ______ A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : In the illustration, the assembly labeled 2 is a ________. EL-0001 A. wound rotor and shaft for a single phase induction motor B. conduction rotor and shaft for a polyphase induction motor C. ... cage rotor and shaft for a polyphase motor D. squirrel cage rotor for a single phase induction motor

Last Answer : Answer: C

Description : Which type of rotor is used in single phase motors?

Last Answer : Squirrel cage type

Description : A synchro has (A) a 3-phase winding on rotor and a single-phase winding on stator. (B) a 3-phase winding on stator and a commutator winding on rotor. (C) a 3-phase winding on stator and a single-phase winding on rotor. (D) a single-phase winding on stator and a commutator winding on rotor.

Last Answer : Ans: C Synchros : The basic synchro unit called a synchro transmitter. It’s construction similar to that of a Three phase alternator.

Description : The relative speed between the magnetic fields of stator and rotor under steady state operation is zero for a (A) dc machine. (B) 3 phase induction machine. (C) synchronous machine. (D) single phase induction machine.

Last Answer : Ans: all options are correct

Description : In a single phase induction motor driving a fan load, the reason for having a high resistance rotor is to achieve (A) low starting torque (B) quick acceleration (C) high efficiency (D) reduced size

Last Answer : In a single phase induction motor driving a fan load, the reason for having a high resistance rotor is to achieve quick acceleration

Description : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then (A) the flux is constant (B) the flux first decreases and then increases in ... increases and decreases in the opposite direction with the same magnitude (D) current flows through the rotor

Last Answer : In a single-phase induction motor when the rotor is stationary and voltage is applied to the stator, then the flux first decreases and then increases in the same direction

Last Answer : The rotor developed by a single-phase motor at starting is zero.

Description : A single phase 60 Hz generator supplies an inductive load of 4500kW at a power factor of 0.80 lagging by means of a 20 km long overhead transmission line. The line resistance and inductance are 0.0195 ohm and 0.60 mH ... voltage regulation of the line.  (A) 12.59% (B) 16.34% (C) 32.68% (D) 41.15% 

Last Answer : Answer is C

Description : What is the rotor speed of a four pole, 60 cycle, induction motor operating at full load with 3% slip? A. 270 RPM B. 540 RPM C. 873 RPM D. 1746 RPM

Last Answer : Answer: D