Description : A booster is a (a) series wound generator (b) shunt wound generator (c) synchronous generator (d) none of the above
Last Answer : (a) series wound generator
Description : The square root of the ratio of line impedance and shunt admittance is called the (a) surge impedance of the line (b) conductance of the line (c) regulation of the line (d) none of the above
Last Answer : (a) surge impedance of the line
Description : A variable shunt, connected across the series field coils of a DC compound wound generator, to permit adjustment of the degree of compounding, is called a _____________. A. divider B. diverter C. converter D. rheostat
Last Answer : Answer: B
Description : The simplest method of controlling the terminal voltage of compound-wound DC generator is with a _____________. A. hand-operated field rheostat connected in series with the shunt field circuit B. ... in series with the load D. balance coil diverting neutral current through the shunt field
Last Answer : Answer: A
Description : The minimum clearance between the ground and a 220 kV line is about (a) 4.3 m (b) 5.5 m (c) 7.0 m (d) 10.5 m
Last Answer : (c) 7.0 m
Description : The material commonly used for sheaths of underground cables is (a) lead (b) rubber (c) copper (d) iron
Last Answer : (a) lead
Description : The material generally used for armour of high voltage cables is (a) aluminium (b) steel (c) brass (d) copper
Last Answer : (b) steel
Description : In transmission lines the crossarms are made of (a) copper (b) wood (c) R.C.C. (d) steel
Last Answer : (d) steel
Description : Overhead lines generally use (a) copper conductors (b) all aluminium conductors (c) A.C.S.R. conductors (d) none of these
Last Answer : (c) A.C.S.R. conductors
Description : The material commonly used for insulation in high voltage cables is (a) lead (b) paper (c) rubber (d) none of the above
Last Answer : (b) paper
Description : Distribution lines in India generally use (a) wooden poles (b) R.C.C. poles (c) steel towers (d) none of the above
Last Answer : (b) R.C.C. poles
Description : Multicore cables generally use (a) square conductors (b) circular conductors (c) rectangular conductors (d) sector-shaped conductors (e) none of the above
Last Answer : (d) sector-shaped conductors
Description : High voltage transmission lines use (a) suspension insulators (b) pin insulators (c) both (a) and (b) (d) none of the above
Last Answer : (a) suspension insulators
Description : The distributors for residential areas are (a) single phase (b) three-phase three wire (c) three-phase four wire (d) none of the above
Last Answer : (c) three-phase four wire
Description : Most of the high voltage transmission lines in India are (a) underground (b) overhead (c) either of the above (d) none of the above
Last Answer : (b) overhead
Description : The voltage of the single phase supply to residential consumers is (a) 110 V (b) 210 V (c) 230 V (d) 400 V
Last Answer : (c) 230 V
Description : Besides a method of trial and error, which of the following methods is employed for solution of network problems in interconnected system ? (a) Circulating current method (b) Thevenin's theorem (c) Superposition of currents (d) Direct application of Kirehhoffs laws (e) All of the above
Last Answer : (e) All of the above
Description : Which of the following D.C. distribution system is the simplest and lowest in first cost ? (a) Radial system (b) Ring system (c) Inter-connected system (d) None of the above
Last Answer : (a) Radial system
Description : Due to which of the following reasons the cables should not be operated too hot ? (a) The oil may loose its viscosity and it may start drawing off from higher levels (b) Expansion of the ... instability may rise due to the rapid increase of dielectric losses with temperature (e) All of the above
Description : Which of the following methods is used for laying of underground cables ? (a) Direct laying (b) Draw-in-system (c) Solid system (d) All of the above
Last Answer : (d) All of the above
Description : The operating voltage of extra high tension cables is upto (a) 6.6 kV (b) 11 kV (c) 33 kV (d) 66 kV (e) 132 kV
Last Answer : (d) 66 kV
Description : The operating voltage of supertension cables is up to (a) 3.3 kV (b) 6.6 kV (c) 11 kV (d) 33 kV
Last Answer : (d) 33 kV
Description : The operating voltage of high voltage cables is up to (a)l.lkV (b)3.3kV (c)6.6kV (d)llkV
Last Answer : (d)llkV
Description : Which of the following is the demerit of a 'constant voltage transmission system' ? (a) Increase of short-circuit current of the system (b) Availability of steady voltage at all loads at ... of carrying increased power for a given conductor size in case of long-distance heavy power transmission
Last Answer : (a) Increase of short-circuit current of the system
Description : The phenomenon qf rise in voltage at the receiving end of the open-circuited or lightly loaded line is called the (a) Seeback effect (b) Ferranti effect (c) Raman effect (d) none of the above
Last Answer : (b) Ferranti effect
Description : 310 km line is considered as (a) a long line (b) a medium line (c) a short line (d) any of the above
Last Answer : (a) a long line
Description : Which of the following are the constants of the transmission lines ? (a) Resistance (b) Inductance (c) Capacitance (d) All of the above
Description : The corona is considerably affected by which of the following ? (a) Size of the conductor (b) Shape of the conductor (c) Surface condition of the conductor (d) All of the above
Description : The usual spans with R.C.C. poles are (a) 40—50 meters (b) 60—100 meters (c) 80—100 meters (d) 300—500 meters
Last Answer : (c) 80—100 meters
Description : Galvanised steel wire is generally used as (a) stay wire (b) earth wire (c) structural components (d) all of the above
Last Answer : (d) all of the above
Description : Which of the following materials is not used for transmission and distribution of electrical power ? (a) Copper (b) Aluminium (c) Steel (d) Tungsten
Last Answer : (d) Tungsten
Description : The wooden poles well impregnated with creosite oil or any preservative compound have life (a) from 2 to 5 years (b) 10 to 15 years (c) 25 to 30 years (d) 60 to 70 years
Last Answer : (c) 25 to 30 years
Description : If variable part of annual cost on account of interest and depreciation on the capital outlay is equal to the annual cost of electrical energy wasted in the conductors, the total annual cost will be minimum and the ... (b) Ohm's law (c) Kirchhoffs law (d) Faraday's law (e) none of the above
Last Answer : (a) Kelvin's law
Description : Overhead system can be designed for operation up to (a) 11 kV (b) 33 kV (c) 66 kV (d) 400 kV
Last Answer : (c) 66 kV
Description : The underground system cannot be operated above (a) 440 V (b) 11 kV (c) 33 kV (d) 66 kV
Description : are the conductors, which connect the consumer's terminals to the distribution (a) Distributors (b) Service mains (c) Feeders (d) None of the above
Last Answer : (b) Service mains
Description : By which of the following systems electric power may be transmitted ? (a) Overhead system (b) Underground system (c) Both (a) and (b) (d) None of the above
Last Answer : (c) Both (a) and (b)
Description : A motor which can conveniently be operated at lagging as well as leading power factors is the (A) squirrel cage induction motor. (B) wound rotor induction motor. (C) synchronous motor. (D) DC shunt motor.
Last Answer : (C) synchronous motor.
Description : A shunt-wound DC generator is one in which the shunt field windings are in parallel with the _____________. A. commutator B. brushes C. armature D. all of the above
Last Answer : Answer: D
Description : An 8 pole lap wound DC shunt generator is supplying 295A to a load. The field current of the generator is 5A. The current per parallel path is: - a) 300A b) 200A c) 150A d) 37.5A
Last Answer : An 8 pole lap wound DC shunt generator is supplying 295A to a load. The field current of the generator is 5A. The current per parallel path is: - 37.5A
Description : The electrical diagram shown in the illustration represents a ___________. EL-0054 A. series-wound motor B. shunt-wound motor C. compound-wound motor D. flat-compounded motor
Last Answer : Answer: C
Description : Which of the methods listed is used to maintain the division of load between two compound-wound, DC generators operating in parallel? A. The shunt fields are interconnected. B. The shunt ... generators are connected in series. D. The equalizer connection parallels the series fields of all machines.
Description : In the construction of D.C. motors, parts of both the series and shunt fields are wound on the _____________. A. opposite main pole B. rotor core C. interpole D. same main pole
Description : In a series wound motor, the current passing through the field windings is also passing through the _____________. A. armature B. shunt field C. reactance comparator D. laminations
Description : Shunt, series, and compound wound motors, are all DC motors designed to operate from _____________. A. constant potential, variable current DC sources B. variable potential, constant current DC ... C. variable potential, variable current DC sources D. constant potential, constant current DC sources
Description : Which of the methods listed is used to maintain equal load sharing between two compound wound DC generators operating in parallel? A. The shunt fields are interconnected. B. The shunt field rheostats ... are connected in series. D. The series fields of both generators are connected in parallel.
Description : What type of electric motor is commonly used to start small auxiliary diesel engines? A. synchronous B. series C. shunt D. cage
Description : The speed-torque characteristics of a DC series motor are approximately similar to those of the _________motor. (A) universal (B) synchronous (C) DC shunt (D) two-phase
Last Answer : Ans: A Universal motor has same characteristics as DC series motor and also known as an a.c series motor.
Description : The length cf air gap to be provided in ______ is primarily determined by power factor consideration. (a) d.c. series motor . (b) d.c. shunt motor (c) induction motor (d) synchronous motor
Last Answer : (c) induction motor
Description : Which of the following equipment, for regulating the voltage in distribution feeder, will be most economical ? (a) Static condenser (b) Synchronous condenser (c) Tap changing transformer (d) Booster transformer
Last Answer : (d) Booster transformer