Due to which of the following reasons the cables should not be operated too hot ? (a) The oil may loose its viscosity and it may start drawing off from higher levels (b) Expansion of the oil may cause the sheath to burst (c) Unequal expansion may create voids in the insulation which will lead to ionization (d) The thermal instability may rise due to the rapid increase of dielectric losses with temperature (e) All of the above

1 Answer

Answer :

(e) All of the above

Related questions

Description : Solid type cables are considered unreliable beyond 66 kV because (a) insulation may melt due to higher temperature (b) skin effect dominates on the conductor (c) of corona loss between conductor and sheath material (d) there is a danger of breakdown of insulation due to the presence of voids

Last Answer : (d) there is a danger of breakdown of insulation due to the presence of voids

Description : The material commonly used for insulation in high voltage cables is (a) lead (b) paper (c) rubber (d) none of the above

Last Answer : (b) paper

Description : The material commonly used for sheaths of underground cables is (a) lead (b) rubber (c) copper (d) iron

Last Answer : (a) lead

Description : Which of the following is the demerit of a 'constant voltage transmission system' ? (a) Increase of short-circuit current of the system (b) Availability of steady voltage at all loads at ... of carrying increased power for a given conductor size in case of long-distance heavy power transmission

Last Answer : (a) Increase of short-circuit current of the system

Description : Multicore cables generally use (a) square conductors (b) circular conductors (c) rectangular conductors (d) sector-shaped conductors (e) none of the above

Last Answer : (d) sector-shaped conductors

Description : The operating voltage of extra high tension cables is upto (a) 6.6 kV (b) 11 kV (c) 33 kV (d) 66 kV (e) 132 kV

Last Answer : (d) 66 kV

Description : The underground system cannot be operated above (a) 440 V (b) 11 kV (c) 33 kV (d) 66 kV

Last Answer : (d) 66 kV

Description : The material generally used for armour of high voltage cables is (a) aluminium (b) steel (c) brass (d) copper

Last Answer : (b) steel

Description : Which of the following methods is used for laying of underground cables ? (a) Direct laying (b) Draw-in-system (c) Solid system (d) All of the above

Last Answer : (d) All of the above

Description : The operating voltage of supertension cables is up to (a) 3.3 kV (b) 6.6 kV (c) 11 kV (d) 33 kV

Last Answer : (d) 33 kV

Description : The operating voltage of high voltage cables is up to (a)l.lkV (b)3.3kV (c)6.6kV (d)llkV

Last Answer : (d)llkV

Description : The phenomenon qf rise in voltage at the receiving end of the open-circuited or lightly loaded line is called the (a) Seeback effect (b) Ferranti effect (c) Raman effect (d) none of the above

Last Answer : (b) Ferranti effect

Description : Plate towers are preferred to packed towers, when large temperature changes are involved, because of the reason that the (A) Packing may be crushed due to thermal expansion/contraction of the ... C) Viscosity variation of the fluids may cause channelling/flooding (D) None of these

Last Answer : (A) Packing may be crushed due to thermal expansion/contraction of the components of the equipments

Description : The wooden poles well impregnated with creosite oil or any preservative compound have life (a) from 2 to 5 years (b) 10 to 15 years (c) 25 to 30 years (d) 60 to 70 years

Last Answer : (c) 25 to 30 years

Description : By which of the following systems electric power may be transmitted ? (a) Overhead system (b) Underground system (c) Both (a) and (b) (d) None of the above

Last Answer : (c) Both (a) and (b)

Description : In single core cables armouring is not done to (a) avoid excessive sheath losses (b) make it flexible (c) either of the above (d) none of the above

Last Answer : (a) avoid excessive sheath losses

Description : Line losses in a distribution circuit are kept to a minimum by __________. A. adding rubber insulation conductors to the circuit B. using higher current and lower voltage C. increasing the number of thermal relays in the circuit D. using higher voltage and lower current

Last Answer : Answer: D

Description : Besides a method of trial and error, which of the following methods is employed for solution of network problems in interconnected system ? (a) Circulating current method (b) Thevenin's theorem (c) Superposition of currents (d) Direct application of Kirehhoffs laws (e) All of the above

Last Answer : (e) All of the above

Description : If variable part of annual cost on account of interest and depreciation on the capital outlay is equal to the annual cost of electrical energy wasted in the conductors, the total annual cost will be minimum and the ... (b) Ohm's law (c) Kirchhoffs law (d) Faraday's law (e) none of the above

Last Answer : (a) Kelvin's law

Description : The minimum clearance between the ground and a 220 kV line is about (a) 4.3 m (b) 5.5 m (c) 7.0 m (d) 10.5 m

Last Answer : (c) 7.0 m

Description : In transmission lines the crossarms are made of (a) copper (b) wood (c) R.C.C. (d) steel

Last Answer : (d) steel

Description : Overhead lines generally use (a) copper conductors (b) all aluminium conductors (c) A.C.S.R. conductors (d) none of these

Last Answer : (c) A.C.S.R. conductors

Description : Distribution lines in India generally use (a) wooden poles (b) R.C.C. poles (c) steel towers (d) none of the above

Last Answer : (b) R.C.C. poles

Description : High voltage transmission lines use (a) suspension insulators (b) pin insulators (c) both (a) and (b) (d) none of the above

Last Answer : (a) suspension insulators

Description : The distributors for residential areas are (a) single phase (b) three-phase three wire (c) three-phase four wire (d) none of the above

Last Answer : (c) three-phase four wire

Description : Most of the high voltage transmission lines in India are (a) underground (b) overhead (c) either of the above (d) none of the above

Last Answer : (b) overhead

Description : The voltage of the single phase supply to residential consumers is (a) 110 V (b) 210 V (c) 230 V (d) 400 V

Last Answer : (c) 230 V

Description : A booster is a (a) series wound generator (b) shunt wound generator (c) synchronous generator (d) none of the above

Last Answer : (a) series wound generator

Description : Which of the following D.C. distribution system is the simplest and lowest in first cost ? (a) Radial system (b) Ring system (c) Inter-connected system (d) None of the above

Last Answer : (a) Radial system

Description : The square root of the ratio of line impedance and shunt admittance is called the (a) surge impedance of the line (b) conductance of the line (c) regulation of the line (d) none of the above

Last Answer : (a) surge impedance of the line

Description : 310 km line is considered as (a) a long line (b) a medium line (c) a short line (d) any of the above

Last Answer : (a) a long line

Description : Which of the following are the constants of the transmission lines ? (a) Resistance (b) Inductance (c) Capacitance (d) All of the above

Last Answer : (d) All of the above

Description : The corona is considerably affected by which of the following ? (a) Size of the conductor (b) Shape of the conductor (c) Surface condition of the conductor (d) All of the above

Last Answer : (d) All of the above

Description : The usual spans with R.C.C. poles are (a) 40—50 meters (b) 60—100 meters (c) 80—100 meters (d) 300—500 meters

Last Answer : (c) 80—100 meters

Description : Galvanised steel wire is generally used as (a) stay wire (b) earth wire (c) structural components (d) all of the above

Last Answer : (d) all of the above

Description : Which of the following materials is not used for transmission and distribution of electrical power ? (a) Copper (b) Aluminium (c) Steel (d) Tungsten

Last Answer : (d) Tungsten

Description : Overhead system can be designed for operation up to (a) 11 kV (b) 33 kV (c) 66 kV (d) 400 kV

Last Answer : (c) 66 kV

Description : are the conductors, which connect the consumer's terminals to the distribution (a) Distributors (b) Service mains (c) Feeders (d) None of the above

Last Answer : (b) Service mains

Description : The minimum dielectric stress in a cable is at (a) armour (b) bedding (c) conductor surface (d) lead sheath

Last Answer : (d) lead sheath

Description : The advantage of oil filled cables is (a) more perfect impregnation (b) smaller overall size (c) no ionisation, oxidation and formation of voids (d) all of the above

Last Answer : (d) all of the above

Description : 45 The function of conservator in a transformer is A. To protect against internal fault B. To reduce copper as well as core losses C. To cool the transformer oil D. To take care of the expansion and contraction of transformer oil due to variation of temperature of surroundings

Last Answer : D. To take care of the expansion and contraction of transformer oil due to variation of temperature of surroundings

Description : When a megohmmeter is used to test insulation, the gradual rise of the pointer reading as a result of continued cranking, is caused by _____________. A. good conductor resistance B. the ... insulation C. the inductive reactance of the windings D. the dielectric-absorption effect of the insulation

Last Answer : Answer: D

Description : The removal of paint from electrical equipment, such as generators, should be cautiously undertaken because ____________. A. the mechanical shock of paint removal lessens the dielectric strength ... phase windings frequently become isolated from each other due to dust interference at the terminals

Last Answer : Answer: B

Description : Which of the following statements are true of elevated-anion gap metabolic acidosis? A. Hypoperfusion from the shock state rarely produces an elevated anion gap. B. Retention of sulfuric and phosphoric ... E. Use of lactated Ringer's solution is inappropriate in the treatment of lactic acidosis.

Last Answer : Answer: BC DISCUSSION: An elevated anion gap may be produced by lactic acidosis from shock or by retention of inorganic acids from uremia. Lactated Ringer's solution rapidly corrects the ... . Bicarbonate loss from diarrhea and dilutional acidosis are non-anion gap types of metabolic acidosis

Description : Which of the following statement(s) is/are true concerning metabolic derangements in sepsis and the systemic inflammatory response syndrome which may follow progressive shock? a. Alterations in glucose ... The serum aromatic amino acids fall rapidly as they are actively used in oxidative metabolism

Last Answer : Answer: b, c A broad spectrum of metabolic abnormalities become apparent in sepsis and the systemic inflammatory response syndrome following shock. Disruption of the normal cycles of carbohydrate, ... acetyl coenzyme A. This results in reduced serum level of leucine, isoleucine and valine

Description : Photosynthesis in C4 plants is relatively less limited by atmospheric CO2 levels because (a) effective pumping of CO2 into bundle sheath cells (b) RuBisCO in C4 plants has higher affinity for CO2 (c ... d) the primary fixation of CO2 is mediated via PEP carboxylase. (2005) 65. In sugarcane plant

Last Answer : (d) the primary fixation of CO2 is mediated via PEP carboxylase.

Description : All of the following conditions are indicators of possible pressures on an entity except a. The industry in which the entity operates is declining. b. There is inadequate working capital ... products or customers. d. There is a significant and prolonged understaffing of the accounting department

Last Answer : There is a significant and prolonged understaffing of the accounting department

Description : Bulking of sand is caused due to (A) Surface moisture (B) Air voids (C) Viscosity (D) Clay contents

Last Answer : Answer: Option A

Description : The material commonly used for insulation in high voltage cables is (a) lead (b) paper (c) rubber (d) none of the above

Last Answer : (b) paper