What is the plugging of an induction motor?

1 Answer

Answer :

It is an electrical braking of an induction motor by sudden reversal of phase sequence.  

Related questions

Description : Draw power and control circuit for simple plugging of induction motor.

Last Answer : Fig. Power and control circuit for simple plugging of induction motor.

Description : What is mean by plugging in three phase induction motor?

Last Answer : Plugging in three-phase induction motor means interchanging of any two phases of a stator for quick stopping.

Description : When using a multimeter for resistance measurements, it should be calibrated by clipping the loose ends of the leads together and _____________. A. setting the instrument pointer at 'zero' ohms B. ... the plus and minus terminals D. using a special purpose resistance measuring instrument (a bridge)

Last Answer : Answer: A

Description : What is meant by plugging?

Last Answer : It is one method of braking of induction motor. When phase sequence of supply of the motor running at a speed is reversed, by interchanging connections of any two phases of stator with respect to supply terminals, operations shifts from motoring to plugging region.

Description : What is Plugging?

Last Answer : The instant reversal of motor is called plugging. Damage to the driven machinery can be result if plugging is applied improperly. 

Description : What is ice plugging? 

Last Answer : If there is a need to repair a valve of D20 PHT system, there are no other valves to shut of D20. So we use plastic bags on pipes and it has dry ice. Then liquid nitrogen is poured ... D20 inside pipeline solidifies preventing any flow of D20 when valve is removed. This is called the ice plugging. 

Description : A 3 phase 50 Hz induction motor has full load speed of 970 rpm. Calculate no of poles and slip frequency.

Last Answer : The number of poles in an induction motor can be calculated using the following formula: No. of poles = (120 * frequency) / speed In this case, the number of poles would be calculated as follows: No. of poles = ( ... ) - 50 Hz = 8.08 Hz So the motor has 6 poles and a slip frequency of 8.08 Hz.

Description : Squirrel cage induction motor has a) Zero starting torque b) Very small starting torque c) Medium starting torque d) Very high starting torque

Last Answer : Ans: B

Description : If the residual flux is absent in the rotor iron of the isolated induction generator, a) it will not run. b) it will run as induction motor c) it will burn the winding d) it will not affect the characteristic of the generator

Last Answer : Ans: A

Description : A four pole, 60 Hz, three-phase synchronous motor comes up to 1760 RPM when started as an induction motor. What is the percent slip after the rotor field is energized? A. 0 B. 1.1 C. 2.2 D. 3.3

Last Answer : Answer: A

Description : The torque and current curves for a three-phase induction motor with a cage rotor, are shown in the illustration. Which of the following statements is true concerning the depicted curves? EL-0056 A. As slip ... D. If the motor is loaded to the point where 40% slip has resulted, it will stall.

Last Answer : Answer: D

Description : Which statement is true concerning a split-phase induction motor? A. Motor rotation can be reversed without changing the windings or leads. B. Motor speed can be readily adjusted from zero to full ... proper wiring. D. Motor rotation can be reversed by reversing the leads on the starting winding.

Last Answer : Answer: D

Description : Which of the listed motors will operate at the highest RPM, assuming that each operates at the same frequency? A. A four-pole synchronous motor under normal load. B. A four-pole induction motor under ... A six-pole synchronous motor under normal load. D. A six-pole induction motor under full load.

Last Answer : Answer: A

Description : The speed of a squirrel-cage, multi-speed, induction motor, as used aboard ship, is varied by changing the __________. A. number of connected poles in the stator B. frequency to the motor C. excitation voltage D. resistance of the rotor circuit

Last Answer : Answer: A

Description : A four-pole 60-hertz induction motor has a synchronous speed of 1800 RPM and a slip of 4 percent at full load. What will be its full load speed? A. 1728.0 RPM B. 1730.7 RPM C. 1800.0 RPM D. 1872.0 RPM

Last Answer : Answer: A

Description : A single-phase induction motor starts, comes up to about 75% rated speed, slows down to a lower speed, and accelerates again. The problem is most likely in the ____________. A. starting winding B. running winding C. starting capacitor D. running centrifugal switch

Last Answer : Answer: B

Description : If a single-phase induction motor fails to start, the problem may be _____________. A. an open in the main winding B. a shorted shunt field C. a closed centrifugal switch D. low circuit frequency

Last Answer : Answer: A

Description : If the synchronous speed of a 12 pole, polyphase, induction motor operating at 60 Hz were 600 RPM, how many poles will be required in a similar motor operating at the same frequency but having a synchronous speed of 900 RPM? A. 4 B. 6 C. 8 D. 18

Last Answer : Answer: C

Description : A four-pole induction motor, operating on three-phase 60 cycle current will operate at approximately ___________. A. 850 RPM B. 1,150 RPM C. 1,750 RPM D. 3,550 RPM

Last Answer : Answer: C

Description : If a single-phase induction motor fails to start, the problem may be _____________. A. an open in the run winding B. a shorted shunt field C. a closed centrifugal switch D. low circuit frequency

Last Answer : Answer: A

Description : What is the rotor speed of a four pole, 60 cycle, induction motor operating at full load with 3% slip? A. 270 RPM B. 540 RPM C. 873 RPM D. 1746 RPM

Last Answer : Answer: D

Description : A single-phase induction motor will only start if you spin the rotor rapidly with the line switch closed. After starting, its speed fluctuates between very slow and half-speed. The problem ... in the ________. A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : The following air gap readings were obtained from a horizontally mounted, bilge pump, induction motor, equipped with sleeve bearings: FWD END-AFT END, Top .045 - .049, Right Side .045 - .047, Left ... the aft bearing. C. The forward bearing should be lowered. D. The aft bearing should be lowered.

Last Answer : Answer: A

Description : If a three-phase induction motor is operated under a light load and it develops an open in one of its supply lines, the motor will _____________. A. continue to run, but will vibrate and have reduced ... speed up due to the reduced number of poles C. run cooler due to reduced current flow D. stop

Last Answer : Answer: A

Description : A split-phase induction squirrel-cage motor will not come up to speed, even though the rated voltage, rated frequency, and rated load are applied. The suspected trouble could be due to _____________. A. a faulty centrifugal switch B. broken rotor bars C. worn bearings D. all of the above

Last Answer : Answer: D

Description : A three-phase, squirrel cage, induction motor will run hot due to a/an ______________. A. improper brush position B. reversed commutating pole C. shorted stator D. high power factor

Last Answer : Answer: C

Description : A three-phase, squirrel cage, induction motor will run hot due to _____________. A. open stator coils B. high power factor C. dirty or corroded slip rings D. reversed commutating poles

Last Answer : Answer: A

Description : If the centrifugal switch or relay used for cutting out the starting winding of a split-phase induction motor fails to open once the motor is in operation, the _____________. A. motor will overspeed B ... C. motor will immediately stall under load D. motor torque will be above normal at rated speed

Last Answer : Answer: B

Description : A single-phase induction motor fails to start. The rotor is spun rapidly with the line switch closed. Having started by this method it is noted that the motor fluctuates between a very slow ... lies in the ______ A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : Which of the following problems will most likely occur if the starting winding of a split-phase induction motor failed to cutout once the motor was in continuous operation? A. The motor will overspeed. B. The ... reduced speed. C. A time delay will stop the motor. D. The winding will burn out.

Last Answer : Answer: D

Description : In the illustrated ground detection system with a ground on phase A, if the switch is opened __________. EL-0009 A. lamp A will dim or go out depending on the severity of the ground B. all three ... lamp A will be brighter D. lamp A will start flickering if the ground is in an AC induction motor

Last Answer : Answer: B

Description : The following air gap readings were obtained from a horizontally mounted, bilge pump, induction motor, equipped with sleeve bearings: FWD END -AFT END, Top .045 - .049 , Right Side .045 - .047, Left ... the aft bearing. C. The forward bearing should be lowered. D. The aft bearing should be lowered.

Last Answer : Answer: A

Description : In the illustrated device, the part labeled '1A' _________. EL-0001 A. are start and run windings for a single phase shaded pole induction motor B. is the stator for a polyphase induction ... armature for a squirrel cage rotor motor D. are direct current shunt field windings for a universal motor

Last Answer : Answer: B

Description : In the illustration, the assembly labeled 2 is a ________. EL-0001 A. wound rotor and shaft for a single phase induction motor B. conduction rotor and shaft for a polyphase induction motor C. ... cage rotor and shaft for a polyphase motor D. squirrel cage rotor for a single phase induction motor

Last Answer : Answer: C

Description : The air gap in an induction motor should be checked periodically with a feeler gage to detect ____________. A. rotor contact with the laminations B. changes in armature magnetic strength C. excessive bearing wear D. electrical damage to the rotor

Last Answer : Answer: C

Description : The air gap in an induction motor should be periodically checked with a feeler gage to prevent possible ___________. A. rotor contact with the stator B. axial misalignment of the rotor C. damage to the motor bearings D. electrical damage to the bearings

Last Answer : Answer: A

Description : The reversal of an AC, three-phase, induction motor is accomplished by ______________. A. changing all three motor leads B. reversing the position of the slip rings C. interchanging any two of the three motor leads D. interchanging any two brushes

Last Answer : Answer: C

Description : The rotation of a three-phase induction motor can be reversed by _____________. A. interchanging any two of the three line leads to the stator B. disconnecting one of the three line leads to the ... the shunt field coil leads D. permanently disconnecting any two of the three line leads to the stator

Last Answer : Answer: A

Description : The speed of a multi-speed, squirrel-cage, induction motor operating in a fixed frequency system can be changed by _____________. A. reconnecting stator windings for different numbers of poles B. ... sequence of the applied voltage D. reconnecting the stator so that no poles have the same polarity

Last Answer : Answer: A

Description : The air gap provided in induction motors should be checked periodically with a feeler gage to detect an unequal air gap and _____________. A. decreased motor magnetizing current B. hysteresis loses C. increased power factor D. mechanical damage to the rotor

Last Answer : Answer: D

Description : The speed of a squirrel-cage induction motor is determined by the ____________. A. diameter of the stator B. number of stator poles C. rotor winding resistance D. rotor conducting bars resistance

Last Answer : Answer: B

Description : In a three-phase, squirrel-cage type, induction motor the rotating magnetic field is established by the _____________. A. current induced in the rotor windings B. application of a three-phase voltage ... caused by the induced current in the squirrel-cage bars with the magnetic field of the stator

Last Answer : Answer: B

Description : Under normal conditions, the speed of a two-speed squirrel cage induction motor is changed by varying the ____________. A. frequency of the applied voltage B. resistance in the rotor circuit C. number of field poles D. amplitude of the applied voltage

Last Answer : Answer: C

Description : A characteristic of a wound-rotor induction motor, with a high resistance rotor winding, is _____________. A. low starting torque B. high starting torque C. high speed D. low starting voltage

Last Answer : Answer: B

Description : If an induction motor were to be operated at 90% rated voltage, _____________. A. there would be an increase in starting torque B. starting current would increase slightly C. synchronous speed would decrease slightly D. the slip would increase

Last Answer : Answer: D

Description : A characteristic of an induction motor with a low resistance rotor winding is _____________. A. high starting voltage B. high starting current C. high slippage D. low starting voltage

Last Answer : Answer: B

Description : Reversing any two of the three rotor leads on a wound-rotor induction motor will _____________. A. increase motor performance B. decrease motor performance C. reverse the motor rotation D. have no effect on the direction of rotation or motor performance

Last Answer : Answer: D

Description : The speed of a wound-rotor induction motor _____________. A. will be fixed by the number of field poles B. can be varied by a rheostat-type control C. can only be synchronous speed at full load D. can only attain synchronous speed at no load

Last Answer : Answer: B

Description : The synchronous speed of an induction motor is the ________. A. speed at which the rotor turns B. speed of the rotating field C. frequency of the rotor current D. slip in per cent of rotor RPM

Last Answer : Answer: B