What are the different methods of firing circuits for line commutated converter?

1 Answer

Answer :

a.  UJT firing circuit.
b.  The cosine wave crossing pulse timing control.
c.  Digital firing schemes.

Related questions

Description : What are the disadvantages of load commutated chopper?

Last Answer : a. For high power applications, efficiency becomes very low because of high switching losses at high operating frequencies. b. Freewheeling diode is subjected to twice the supply voltage. c ... other pair is commutated. This can be realized by sensing the capacitor current that is alternating.

Description : What are the advantages of load commutated chopper?

Last Answer : a. Commutating inductor is not required. b. It is capable of commutating any amount of load current. c. It can work at high frequencies in the order of kHz. d. Filtering requirements are minimal.

Description : What are the advantages of current commutated chopper?

Last Answer : a. The capacitor always remains charged with the correct polarity. b. Commutation is reliable as load current is less than the peak commutation current ICP. c. The auxiliary thyristor TA is naturally commutated as its current passes through zero value.

Description : What is the control range of firing angle inac voltage controller with RL load?

Last Answer : The control range is Φ< α

Description : What is delay angle or what is firing angle of phase controlled rectifier?

Last Answer : The delay angle is the angle at which thyristors are triggered after zero crossing. After zero crossing of supply voltage, one pair of thyristors is forward biased. After delay angle(α) these SCRs are triggered.

Description : What is firing angle?

Last Answer : The angle between the zero crossing of the input voltage and the instant the SCR is fired is called as delay angle or firing angle.

Description : What is meant by negative converter group in a cycloconverter?

Last Answer : The part of the cycloconverter circuit that permits the flow of current during negative half cycle of output current is called negative converter group.

Description : What is meant by positive converter group in a cycloconverter?

Last Answer : The part of the cycloconverter circuit that permits the flow of current during positive half cycle of output current is called positive converter group.

Description : What are the applications of cyclo-converter?

Last Answer : a. Induction heating b. Speed control of high power ac drives c. Static VAR generation d. Power supply in aircraft or ship boards

Description : What is meant by cyclo-converter?

Last Answer : It converts input power at one frequency to output power at another frequency with one-stage conversion. Cycloconverter is also known as frequency changer.

Description : What are the advantages of six pulse converter?

Last Answer : a. Commutation is made simple. b. Distortion on the ac side is reduced due to the reduction in lower order harmonics. c. Inductance reduced in series is considerably reduced.

Description : What are the advantages of single phase bridge converter over single phase mid-point converter?

Last Answer : a. SCRs are subjected to a peak-inverse voltage of 2Vm in a fully controlled bridge rectifier. Hence for same voltage and currnt ratings of SCrs, power handled by mid-point configuration is about ... load power. As such, the transformer rating in mid-point converter is double the load rating.

Description : What is step up cyclo-converter ?

Last Answer : It is the converter whose output frequency is more than the input frequency.

Description : What is step down cyclo-converter?

Last Answer : It is the converter whose output frequency is less than the input frequency.

Description : What is meant by cyclo-converter?

Last Answer : It is also known as frequency changer. It converts input power at one frequency to output power at another frequency with one stage conversion.

Description : To design the buck converter, what are basic & essential information (parameters) we need to get from the Customer?

Last Answer : We need the following inputs from the customer,Output Voltage VOUTInput Voltage VINOutput Current (load current) IOUTMaximum Ripple voltage allowed at the output sideEfficiency of the converter

Description : What is the turn-off time for converter grade SCRs and inverter grade SCRs?

Last Answer : Turn-off time for converter grade SCRs is 50 – 100 ms turn-off time for converter grade SCRs and inverter grade SCRs and for inverter grade SCRs is 3 – 50 ms.

Description : Why diodes should be connected in antiparallel with the thyristors in inverter circuits?

Last Answer : For RL loads, load current will not be in phase with load voltage and the diodes connected in antiparallel will allow the current to flow when the main thyristors are turned off. These diodes are called feedback diodes.

Description : What are the different methods to turn on the thyristor?

Last Answer : a. Forward voltage triggering b. Gate triggering c. dv/dt triggering d. Temperature triggering e. Light triggering

Description : What are the different turn on methods of SCR?

Last Answer : Forward voltage triggering Gate Triggering dv/dt triggering Temperature triggering Light triggering

Description : What are the two methods of control in ac voltage controllers?

Last Answer : a. ON-OFF control b. Phase control

Description : What are the methods of reduction of harmonic content?

Last Answer : a. Transformer connections b. Sinusoidal PWM c. Multiple commutation in each cycle d. Stepped wave inverters

Description : A three-phase, fully controlled thyristor bridge converter is used as line commutated inverter to feed 50 kW power 420 V dc to a three-phase, 415 V(line), 50 Hz ac mains. Consider dc link current to be constant. The rms current of the thyristor is  (A) 119.05 A (B) 79.37 A (C) 68.73 A (D) 39.68 A

Last Answer : A three-phase, fully controlled thyristor bridge converter is used as line commutated inverter to feed 50 kW power 420 V dc to a three-phase, 415 V(line), 50 Hz ac mains. Consider dc link current to be constant. The rms current of the thyristor is 68.73 A

Last Answer : When a line commutated converter operates in the inverter mode It delivers real power to the A.C. supply.

Description : What are the different losses that occur in thyristor while operating?

Last Answer : Different losses that occur are Forward conduction losses during conduction of the thyristor Loss due to leakage current during forward and reverse blocking. Power loss at gate or Gate triggering loss. Switching losses at turn-on and turn-off.

Description : What are the different operation regions of the SCR?

Last Answer : SCR or thyristor will have three regions of operations based on the mode in which the device is connected in the circuit. Reverse blocking region: When the cathode of the thyristor is made positive with ... scr. Hence a gate signal is applied before the forward break over voltage to trigger the scr.

Description : What are the different types of chopper with respect to commutation process?

Last Answer : a. Voltage commutated chopper. b. Current commutated chopper. c. Load commutated chopper.

Description : What are the different factors for the selection of electrical drives?

Last Answer : Steady state operation requirements Transient operation requirements Requirements related to the source Capital and running cost, maintenance needs, life Space and weight restrictions Environment and location Reliability

Description : What are the different types of power MOSFET?

Last Answer : a. N-channel MOSFET b. P-channel MOSFET

Description : Why Generation Voltage in Power Plant is Low (11kV to 33kV) ?

Last Answer : Generally electrical power is generated at low voltages (generation voltage will be around 11 to 33kV) depending on the power output rating of the generator and transmitted to the load centers by stepping up the ... operate at 23.5 kV with line currents of about 19,000 A at 0.85 power factor.

Description : What is the relation between the gate signal and forward break over voltage (VBO)?

Last Answer : Thyristor can be triggered by increasing the forward voltage between anode and cathode, at forward break over voltage thyristor starts conducting. However this process may damage the thyristor, so thyristor ... of the gate current. Higher is the gate current lower is the forward break over voltage

Description : Why thyristor is considered as Charge controlled device?

Last Answer : During the triggering process of the thyristor from forward blocking state to forward conduction state through the gate signal, by applying the gate signal (voltage between gate and cathode) increases the ... By controlling the amount of charge we can control the turning on time of the scr.

Description : What is meant by step-down cyclo-converters?

Last Answer : In these converters, the output frequency is more than the supply frequency.

Description : What is meant by step-up cyclo-converters?

Last Answer : In these converters, the output frequency is less than the supply frequency.

Description : What are the two types of cyclo-converters?

Last Answer : a. Step-up cyclo-converters b. Step-down cyclo-converters

Description : What are the advantages of sequence control of ac voltage regulators?

Last Answer : a. System power factor is improved. b. Harmonics are reduced in the source current and the load voltage.

Description : What is meant by sequence control of ac voltage regulators?

Last Answer : It means that the stages of voltage controllers in parallel triggered in a proper sequence one after the other so as to obtain a variable output with low harmonic content.

Description : What is meant by high frequency carrier gating?

Last Answer : Thyristor is turned on by using a train of pulses from αto π. This type of signal is called as high frequency carrier gating.

Description : What are the disadvantages of continuous gating signal?

Last Answer : a. More heating of the SCR gate. b. Increases the size of pulse transformer.

Description : What type of gating signal is used in single phase ac voltage controller with RL load?

Last Answer : High frequency carrier gating signal is used for single phase ac voltage controller with RL load.

Description : What is the difference between ON-OFF control and phase control?

Last Answer : ON-OFF control: In this method, the thyristors are employed as switches to connect the load circuit to the source for a few cycles of the load voltageand disconnect it for another few cycles. Phase ... switches connect the load to the ac source for a portion of each half cycle of input voltage.

Description : What are the disadvantages of ac voltage controllers?

Last Answer : The main draw back is the introduction of harmonics in the supply current and the load voltage waveforms particularly at low output voltages.

Description : What are the advantages of ac voltage controllers?

Last Answer : a. High efficiency b. Flexibility in control c. Less maintenance

Description : What are the applications of ac voltage controllers?

Last Answer : a. Domestic and industrial heating b. Lighting control c. Speed control of single phase and three phase ac motors d. Transformer tap changing

Description : What does ac voltage controller mean?

Last Answer : It is device which converts fixed alternating voltage into a variable voltage without change in frequency.

Description : What are the disadvantages of PWM control?

Last Answer : SCRs are expensive as they must possess low turn-on and turn-off times.

Description : What are the disadvantages of the harmonics present in the inverter system?

Last Answer : a. Harmonic currents will lead to excessive heating in the induction motors. This will reduce the load carrying capacity of the motor. b. If the control and the regulating circuits are not ... affected. d. On critical loads, torque pulsation produced by the harmonic current can be useful.

Description : What are the advantages of PWM control?

Last Answer : a. The output voltage can be obtained without any additional components. b. Lower order harmonics can be eliminated or minimized along with its output voltage control. As the higher order harmonics can be filtered easily, the filtering requirements are minimized.

Description : What is meant by PWM control?

Last Answer : In this method, a fixed dc input voltage is given to the inverter and a controlled ac output voltage is obtained by adjusting the on and off periods of the inverter components. This is the most popular method of controlling the output voltage and this method is termed as PWM control.

Description : What are the applications of a CSI?

Last Answer : a. Induction heating b. Lagging VAR compensation c. Speed control of ac motors d. Synchronous motor starting.