In the illustration, the the device E is the______.  EL-0033 A. bimetal strip B. moving contact C. trip bar D. handle

1 Answer

Answer :

Answer: C

Related questions

Description : In the illustration, the component labeled D is a ______. EL-0033 A. fixed contact B. moving contact C. trip bar D. bimetallic strip

Last Answer : Answer: B

Description : In the illustration the component C is the ____________. EL-0033 A. fixed contact B. moving contact C. connection terminal D. trip bar

Last Answer : Answer: A

Description : Component F in the illustrated device is for _________. EL-0033 A. short circut protection B. latching the trip unit closed after resetting the breaker C. overload protection D. providing a flexible connection between the input terminal G and the tripping unit E

Last Answer : Answer: C

Description : In the illustration, the purpose of part B is to _________. EL-0033 A. increase resistance in series with the contacts as they close to prevent arcing B. create a magnetic field in the steel ... event of an overload D. provide ventilation to the contact when the breaker is close to rated capacity

Last Answer : Answer: B

Description : As shown in the illustration, what is responsible for maintaining the "LV" relay energized when the master switch handle is moved away from the "off" position? EL-0102 A. "DBa" contact. B. Reset contacts. C. Upper set of "LVa" contacts. D. Lower set of "LVa" contacts.

Last Answer : Answer: C

Description : Moving the rheostat handle shown in the illustration, that is used to control a DC generator, towards the 'raise' direction will increase the _____________. EL-0030 A. field resistance B. armature resistance C. armature speed D. line voltage

Last Answer : Answer: D

Description : Where a thermal-acting breaker is required to be used in an area of unusually high, low, or constantly fluctuating temperatures, an ambient compensating element must be used. This element consists of ... arm B. conical spring on the contact arm C. second bimetal element D. second electromagnet

Last Answer : Answer: C

Description : As shown in the illustration, 'S' is the __________. EL-0017 A. safety switch B. overload trip C. start button D. stop button

Last Answer : Answer: D

Description : When the operating handle is in the 'off' position, which master switch contacts for the winch shown in the illustration are closed? EL-0102 A. 'MS-DB & OL' B. 'MS-3, 5, 6, 7, & 8' C. 'MS-LVa & OL' D. 'MS-3, 7 & Reset'

Last Answer : Answer: D

Description : The 'safe switch' of the winch controller shown in the illustration is operated _______________. EL-0102 A. through the master switch handle B. when heater circuit current is high C. by contactor coil 'FR' D. manually by the winch operator

Last Answer : Answer: D

Description : As shown in the illustration, the symbol is used in electrical drawings to designate a ____________. EL-0026 A. limit switch with one set of normally open contacts B. maintaining type ... type push button with a mechanical interlock D. normally closed contact held open mechanically by an interlock

Last Answer : Answer: C

Description : Which of the devices shown in the illustration automatically prevents the simultaneous operation of the windlass from both master switches? EL-0073 A. Selector switch B. Contact 'CR1a' C. Contact 'CR2a' D. Contact 'CR1D'

Last Answer : Answer: D

Description : When an operating motor is connected to the controller shown in the illustration, the a path of current flow through the circuit is ____________. EL-0010 A. 'L1', stop button, start button, coil 'CR', 'L2' B. 'L1' ... L2' D. 'L1', stop button, start button, 'CR' contact, 'M' contact, 'CR' coil, 'L2'

Last Answer : Answer: B

Description : When the motor shown in the illustration is running and the stop button is pushed, which of the following statements will hold true? EL-0010 A. Coil 'M' will now be energized. B. Coil 'CR' will now be energized. C. Contact 'M' will close as contact 'CR' opens. D. Contacts 'M' and 'CR' will open.

Last Answer : Answer: D

Description : As shown in the illustration, which of the operations listed will happen when the 'jog button' is pushed? EL-0010 A. Coil 'CR' closes the normally open 'CR' contacts. B. Coil 'M' opens contact 'M'. C. Coil 'M' closes contact 'M'. D. Contact 'M' remains open despite the jog button being pushed.

Last Answer : Answer: C

Description : As shown in the illustration, which listed action will occur first when push button 'Q' is depressed? EL-0017 A. Contacts 'H-1', 'H-2' and 'H-3' close. B. Contact 'H-4' closes. C. Operating coil 'C' energizes. D. Switch 'R' opens.

Last Answer : Answer: C

Description : If the motor shown in the illustration will not start when 'Q' is depressed, which of the listed components should be checked FIRST? EL-0017 A. Fuses 'F-1' and 'F-2'. B. Operating coil 'C'. C. Contacts 'H-1', 'H-2', and 'H-3'. D. Contact 'H-4'.

Last Answer : Answer: A

Description : If the circuit shown in the illustration were energized and operating properly, which of the devices listed would be open? EL-0007 A. The stop push-button B. The start push-button C. Contact 'Ma' D. Contact 'OL1'

Last Answer : Answer: B

Description : As shown in the illustration, which of the symbols represents a normally closed electrical contact? EL-0005 A. A B. B C. C D. D

Last Answer : Answer: A

Description : What is represented by the electric symbol figure 'D' in the illustration? EL-0005 A. Fuse B. Plug-in contact resistor C. Variable capacitor D. Electrolytic capacitor

Last Answer : Answer: A

Description : The winch shown in the illustration operates in any of the positions with the master switch in the 'lower' direction, but will not 'hoist' in any of the master switch hoist positions. Which of the listed faults ... '2M' in the power circuit may be badly corroded. D. Series relay 'FR' may be open.

Last Answer : Answer: A

Description : In order to prevent the winch shown in the illustration from turning while troubleshooting the controller circuit, _________________. EL-0102 A. set the dynamic brake by clamping contact 'DB' closed B. set the ... at 'B1' and 'B2' D. open the test link preventing current flow to the armature

Last Answer : Answer: D

Description : The motor starts when the start button in the illustration is pushed, but stops when the button is released the trouble is _________. EL-0007 A. the incorrect thermal overload coil B. a faulty 'M' coil C. a dirty contact on the Disc.Sw. at 'L3' D. a faulty holding relay contact

Last Answer : Answer: D

Description : In the illustration the symbol for an N/O contact is_______. EL-0005 A. A B. B C. C D. D

Last Answer : Answer: B

Description : The small circular symbols to which wire '52N57E' is connected at coordinates '57L' and '57P' shown in the illustration represent ___________________. EL-0100 A. relay contact solder points B. wire wrap connections C. terminal board screws D. switch contact terminals

Last Answer : Answer: C

Description : Erratic operation of the devices represented in the diagrams shown in the illustration could be traced to ____________. EL-0092 A. improper contact at 'R' slip rings or 'S' connections B. a low three- ... . improper contact at 'S' slip rings or 'R' connections D. a high three-phase voltage supply

Last Answer : Answer: A

Description : As shown in the illustration, what happens when 'A' is closed, 'B' is in position '2' and component 'E2' burns out? EL-0058 A. 'H' energizes and 'D' makes contact. B. 'F' goes out allowing 'G' to disconnect. C. 'G' sounds an alarm and 'F' illuminates. D. 'C' opens causing 'A' to also open.

Last Answer : Answer: C

Description : When three-phase AC power is supplied to the device shown in the illustration, the output will be _____________. EL-0063 A. single-phase AC B. split-phase AC C. three-phase DC D. unidirectional DC

Last Answer : Answer: D

Description : In the illustration, the signal from the device connected to terminals 18 and 19 is __________. EL-0046 A. prime mover speed feedback B. loss of control alarm when comparing with the input signal ... slip between the prime mover and the alternator D. to shut down the prime mover if overspeeding

Last Answer : Answer: A

Description : The electrical device shown in the illustration is a/an _____________. EL-0077 A. operating coil B. indicating lamp C. motor armature D. potentiometer

Last Answer : Answer: D

Description : In the illustration, if one of the devices labeled 'TURB' should fail the ___________. EL-0003 A. device labeled 'EXC' will drive the alternator B. device labeled 'BKR' for that ... -alternator D. emergency generator should automatically start and be placed on line to supply emergency load centers

Last Answer : Answer: B

Description : The device labeled 'REG SW' in the illustration is used to ___________. EL-0003 A. shift from the automatic voltage regulator to the manual voltage regulator B. shift the governor control from manual to ... device 'REG ADJ' or device 'MAN ADJ' D. supply regulated control power to the switchboard

Last Answer : Answer: A

Description : Before servicing the device indicated as 'A' in panels #1 and #3 of the illustration, the device labeled 'CT' must __________. EL-0003 A. have the disconnected leads taped to prevent ... D. have one lead grounded to discharge static electricity for the prevention of damage to electronic components

Last Answer : Answer: C

Description : The turns ratio of device 'B' shown in the illustration is two to one (total). If 220 volts were applied to terminals 'H1' & 'H2', what would be indicated across 'X1' & 'X4' with 'X2' & 'X3' connected and isolated? EL-0082 A. 55 volts B. 110 volts C. 220 volts D. 440 volts

Last Answer : Answer: B

Description : The device at coordinates '63/1' in the illustration represents a/an _____________. EL-0100 A. A.C. buzzer B. A.C. motor C. D.C. motor D. D.C. relay coil

Last Answer : Answer: D

Description : The device in figure 'B' shown in the illustration can be used to control an AC load yet maintain its high gain by ______________. EL-0091 A. connecting the load to the output side of the ... connecting the load to the input side of the bridge D. reversing the current flow through the bias winding

Last Answer : Answer: C

Description : The purpose of the bias winding in figure 'B' shown in the illustration is for ____________. EL-0091 A. changing the direction of current in the control winding B. setting the operating point of the ... use of either AC or DC in the load circuit D. changing the direction of current through the load

Last Answer : Answer: B

Description : In the illustration, if the device in figure 'A' has a step-up ratio of 10 to 1, what voltage should be measured at the secondary shortly after the primary of the device is connected to 110 volts DC? EL-0059 A. 0 volts B. 110 volts C. 11 volts D. 1100 volts

Last Answer : Answer: A

Description : The device in figure 'B' shown in the illustration will conduct when the ____________. EL-0067 A. base-emitter is forward biased and the collector-base is reverse biased B. anode-cathode is forward ... is reversed biased D. terminal 1-2 is forward biased and the emitter-terminal 1 is reverse biased

Last Answer : Answer: B

Description : The device in figure 'A' shown in the illustration can sometimes have two ____________. EL-0078 A. gates B. emitters C. substrates D. cathodes

Last Answer : Answer: A

Description : The leads of the device in figure 'B' shown in the illustration are named _________. EL-0065 A. source, gate and drain B. emitter, base and collector C. emitter, base 1 and base 2 D. anode, cathode and gate

Last Answer : Answer: A

Description : Leads on the device in figure 'B' shown in the illustration are named ____________. EL-0067 A. source, gate and drain B. emitter, base and collector C. emitter, base 1 and base 2 D. anode, cathode and gate

Last Answer : Answer: D

Description : The turns ratio of device 'B' shown in the illustration is two to one (total). If 110 volts were applied to terminals 'X1,3' and 'X2,4', what would be indicated across 'H1' and 'H2'? EL-0082 A. 27.5 volts B. 55 volts C. 220 volts D. 440 volts

Last Answer : Answer: D

Description : The turns ratio of device 'B' shown in the illustration is two to one (total). If 440 volts were applied to terminals 'H1' & 'H2', what would be indicated across 'X1' & 'X4' with 'X2' & 'X3' connected and isolated? EL-0082 A. 110 volts B. 220 volts C. 880 volts D. 1760 volts

Last Answer : Answer: B

Description : An important characteristic of the device shown in figure 'B' of the illustration as compared with conventional NPN or PNP transistors is its ____________. EL-0065 A. higher temperature sensitivity B. higher power ratings C. very high input resistance D. all of the above

Last Answer : Answer: C

Description : The turns ratio of device 'B' shown in the illustration is two to one (total). If 220 volts were applied to terminals 'H1' and 'H2', what would be indicated across 'X3' and 'X4'? EL-0082 A. 55 volts B. 110 volts C. 440 volts D. 880 volts

Last Answer : Answer: A