1 Answer

Answer :

When the frequency of the rotor of an induction motor is small, it can be measured by d.c. moving coil milli-voltmeter

Related questions

Description : The speed of a squirrel-cage, multi-speed, induction motor, as used aboard ship, is varied by changing the __________. A. number of connected poles in the stator B. frequency to the motor C. excitation voltage D. resistance of the rotor circuit

Last Answer : Answer: A

Description : A split-phase induction squirrel-cage motor will not come up to speed, even though the rated voltage, rated frequency, and rated load are applied. The suspected trouble could be due to _____________. A. a faulty centrifugal switch B. broken rotor bars C. worn bearings D. all of the above

Last Answer : Answer: D

Description : The speed of a multi-speed, squirrel-cage, induction motor operating in a fixed frequency system can be changed by _____________. A. reconnecting stator windings for different numbers of poles B. ... sequence of the applied voltage D. reconnecting the stator so that no poles have the same polarity

Last Answer : Answer: A

Description : Under normal conditions, the speed of a two-speed squirrel cage induction motor is changed by varying the ____________. A. frequency of the applied voltage B. resistance in the rotor circuit C. number of field poles D. amplitude of the applied voltage

Last Answer : Answer: C

Description : The synchronous speed of an induction motor is the ________. A. speed at which the rotor turns B. speed of the rotating field C. frequency of the rotor current D. slip in per cent of rotor RPM

Last Answer : Answer: B

Description : The speed of a three-phase squirrel-cage induction-type motor operating in a fixed frequency system is varied by changing the _____________. A. number of phases to the motor B. number of stator poles C. locked rotor current D. resistance of the rotor winding

Last Answer : Answer: B

Description : The variable resistance placed in the rotor circuit of a wound-rotor induction motor provides for __________. A. speed control B. frequency control C. voltage control D. use as a split-phase motor

Last Answer : Answer: A

Description : In Induction motor Slip frequency of rotor current, when rotor speed is Nr. Then rotor producing slip field rotates with respect to stator is a) Slip frequency b) Nr c) Ns d) None

Last Answer : Ans: Ns

Description : The synchronous speed for a 3 phase 6-pole induction motor is 1200 rpm. If the number of poles is now reduced to 4 with the frequency remaining constant, the rotor speed with a slip of 5% will be _________. (A) 1690 rpm (B) 1750 rpm (C) 1500 rpm (D) 1710 rpm

Last Answer : (D) 1710 rpm

Description : The rotor frequency for a 3 phase 1000 RPM 6 pole induction motor with a slip of 0.04 is________Hz (A) 8 (B) 4 (C) 6 (D) 2

Last Answer : Ans: D Given: N=1000 rpm ; P= 6; s= 0.04; and f = NP/ 120 = 10006/120 = 50 Hz Rotor frequency fr=sf = 0.0450 = 2.0 Hz

Description : The frequency of the rotor current in a 3 phase 50 Hz, 4 pole induction motor at full load speed is about (A) 50 Hz. (B) 20 Hz. (C) 2 Hz. (D) Zero.

Last Answer : (C) 2 Hz.

Description : The rotor frequency for a 3-phase 6-pole, 1000 r.p.m. induction motor with a slip of 0.04 is (a) 2 Hz (b) 4 Hz (c) 6 Hz (d) 8 Hz  

Last Answer : 2hz is rotor frequency

Description : The frequency (fr) of the rotor current in an induction motor is given by the expression (s = slip, f = supply frequency)

Last Answer : The frequency (fr) of the rotor current in an induction motor is given by the expression fr = (s. f ) (s = slip, f = supply frequency)

Description : A 3-phase induction motor under locked rotor condition and with stator supply, induces (A) small voltage at slip frequency (B) large voltage at rotor frequency (C) zero voltage at zero frequency (D) large voltage at slip frequency

Last Answer : A 3-phase induction motor under locked rotor condition and with stator supply, induces (A) small voltage at slip frequency (B) large voltage at rotor frequency (C) zero voltage at zero frequency (D) large voltage at slip frequency

Description : The power input to the rotor of a 400V, 50 Hz 6 pole three phase induction motor is 20kW. The slip is 3%. The frequency of rotor currents is: (A) 1 Hz (B) 1.5 Hz (C) 2 Hz (D) 1 2 Hz

Last Answer : C

Description : A centre zero ammeters connected in the rotor circuit of a 6-pole 50 Hz induction motor makes 30 oscillations in one minute. The rotor speed is

Last Answer : A centre zero ammeters connected in the rotor circuit of a 6-pole 50 Hz induction motor makes 30 oscillations in one minute. The rotor speed is 990.

Last Answer : In an induction motor, if the rotor resistance is equal to stand-still reactance then the maximum torque is equal to starting torque.

Last Answer : The purpose of skewing of rotor slots in induction motor is to reduce the locking tendency of rotor.

Description : If the residual flux is absent in the rotor iron of the isolated induction generator, a) it will not run. b) it will run as induction motor c) it will burn the winding d) it will not affect the characteristic of the generator

Last Answer : Ans: A

Description : A four pole, 60 Hz, three-phase synchronous motor comes up to 1760 RPM when started as an induction motor. What is the percent slip after the rotor field is energized? A. 0 B. 1.1 C. 2.2 D. 3.3

Last Answer : Answer: A

Description : The torque and current curves for a three-phase induction motor with a cage rotor, are shown in the illustration. Which of the following statements is true concerning the depicted curves? EL-0056 A. As slip ... D. If the motor is loaded to the point where 40% slip has resulted, it will stall.

Last Answer : Answer: D

Description : What is the rotor speed of a four pole, 60 cycle, induction motor operating at full load with 3% slip? A. 270 RPM B. 540 RPM C. 873 RPM D. 1746 RPM

Last Answer : Answer: D

Description : A single-phase induction motor will only start if you spin the rotor rapidly with the line switch closed. After starting, its speed fluctuates between very slow and half-speed. The problem ... in the ________. A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : A single-phase induction motor fails to start. The rotor is spun rapidly with the line switch closed. Having started by this method it is noted that the motor fluctuates between a very slow ... lies in the ______ A. starting winding B. centrifugal mechanism C. centrifugal switch D. running winding

Last Answer : Answer: D

Description : In the illustrated device, the part labeled '1A' _________. EL-0001 A. are start and run windings for a single phase shaded pole induction motor B. is the stator for a polyphase induction ... armature for a squirrel cage rotor motor D. are direct current shunt field windings for a universal motor

Last Answer : Answer: B

Description : In the illustration, the assembly labeled 2 is a ________. EL-0001 A. wound rotor and shaft for a single phase induction motor B. conduction rotor and shaft for a polyphase induction motor C. ... cage rotor and shaft for a polyphase motor D. squirrel cage rotor for a single phase induction motor

Last Answer : Answer: C

Description : The air gap in an induction motor should be checked periodically with a feeler gage to detect ____________. A. rotor contact with the laminations B. changes in armature magnetic strength C. excessive bearing wear D. electrical damage to the rotor

Last Answer : Answer: C

Description : The air gap in an induction motor should be periodically checked with a feeler gage to prevent possible ___________. A. rotor contact with the stator B. axial misalignment of the rotor C. damage to the motor bearings D. electrical damage to the bearings

Last Answer : Answer: A

Description : The air gap provided in induction motors should be checked periodically with a feeler gage to detect an unequal air gap and _____________. A. decreased motor magnetizing current B. hysteresis loses C. increased power factor D. mechanical damage to the rotor

Last Answer : Answer: D

Description : The speed of a squirrel-cage induction motor is determined by the ____________. A. diameter of the stator B. number of stator poles C. rotor winding resistance D. rotor conducting bars resistance

Last Answer : Answer: B

Description : In a three-phase, squirrel-cage type, induction motor the rotating magnetic field is established by the _____________. A. current induced in the rotor windings B. application of a three-phase voltage ... caused by the induced current in the squirrel-cage bars with the magnetic field of the stator

Last Answer : Answer: B

Description : A characteristic of a wound-rotor induction motor, with a high resistance rotor winding, is _____________. A. low starting torque B. high starting torque C. high speed D. low starting voltage

Last Answer : Answer: B

Description : A characteristic of an induction motor with a low resistance rotor winding is _____________. A. high starting voltage B. high starting current C. high slippage D. low starting voltage

Last Answer : Answer: B

Description : Reversing any two of the three rotor leads on a wound-rotor induction motor will _____________. A. increase motor performance B. decrease motor performance C. reverse the motor rotation D. have no effect on the direction of rotation or motor performance

Last Answer : Answer: D

Description : The speed of a wound-rotor induction motor _____________. A. will be fixed by the number of field poles B. can be varied by a rheostat-type control C. can only be synchronous speed at full load D. can only attain synchronous speed at no load

Last Answer : Answer: B

Description : Regarding an induction motor, the power developed by the rotor automatically adjusts itself to the _____________. A. power required to drive the load B. speed required to drive the load C. current flow in the motor stator D. torque developed by the rotating field

Last Answer : Answer: A

Description : A single-phase induction motor having a relatively high starting torque, is the ___________. A. shaded pole motor B. wound-rotor motor C. capacitor-start motor D. resistance-start motor

Last Answer : Answer: C

Description : In a 15 HP induction-type motor with a cage rotor, the current required at standstill to produce starting torque is approximately ____________. A. half the full load current B. equal to the full load current C. five times the full load current D. ten to twenty times the full load current

Last Answer : Answer: C

Description : The speed of a squirrel cage induction motor is determined by the _____________. A. diameter of the stator B. number of stator poles C. rotor winding resistance D. bar resistance of the conducting rotor

Last Answer : Answer: B

Description : The purpose of a cage rotor winding placed on the rotor of a synchronous motor is to _____________. A. provide excitation to the DC field B. start the machine as an induction motor C. contribute extra torque at synchronous speed D. prevent the machine from falling out of step

Last Answer : Answer: B

Description : A degree of control over the speed of a slip ring induction motor can be obtained by _____________. A. adjusting governor linkage B. changing the number of phases to the motor C. inserting resistance into the stator circuit D. inserting resistance into the rotor circuit

Last Answer : Answer: D

Description : In an induction motor, rotor currents are circulated in the rotor by _____________. A. slip rings and brushes B. an armature and brushes C. inductive reaction of the rotating stator field D. external variable resistors

Last Answer : Answer: C

Description : Which of the following physical characteristics does a wound-rotor induction motor possess that a squirrel cage motor does not? A. Slip rings B. End rings C. A centrifugal switch D. End plates

Last Answer : Answer: A

Description : A motor using a rheostat in the motor circuit to vary the speed is called a ____________. A. squirrel-cage induction motor B. regenerative braking motor C. wound-rotor induction motor D. synchronous motor

Last Answer : Answer: C

Description : Which of the following statements is true concerning a polyphase synchronous propulsion motor? A. The motor is started as an induction motor. B. Resistance is gradually added to the rotor circuit. C. ... is held below the rated current. D. The field winding is energized for starting purposes only.

Last Answer : Answer: A

Description : The rotor power output of a 3-phase induction motor is 15 KW and corresponding slip is 4%. The rotor copper loss will be (A) 600 W. (B) 625 W (C) 650 W (D) 700 W

Last Answer : Ans: B Rotor copper losses = rotor input- rotor output and output = (1-s) input ∴ Input = output/(1-s) = 15000 /1-0.04 = 15625 ∴ loss = 15625 -1500 = 625 watt

Description : A 3-phase, 400 votts, 50 Hz, 100 KW, 4 pole squirrel cage induction motor with a rated slip of 2% will have a rotor speed of (A) 1500 rpm (B) 1470 rpm (C) 1530 rpm (D) 1570 rpm

Last Answer : Ans: B N = NS (1-S) and NS =120 f / p =120 x 50 /4 = 1500 rpm ∴N= 1500 (1-0.02) =1470 rpm

Description : A balanced three-phase, 50 Hz voltage is applied to a 3 phase, 4 pole, induction motor. When the motor is delivering rated output, the slip is found to be 0.05. The speed of the rotor m.m.f. relative to the rotor structure is (A) 1500 r.p.m. (B) 1425 r.p.m. (C) 25 r.p.m. (D) 75 r.p.m.

Last Answer : (D) 75 r.p.m.

Description : A motor which can conveniently be operated at lagging as well as leading power factors is the (A) squirrel cage induction motor. (B) wound rotor induction motor. (C) synchronous motor. (D) DC shunt motor.

Last Answer : (C) synchronous motor.

Description : Explain speed control method of 3 phase induction motor by the following methods: (1) Pole changing (2) Rotor resistance control (3) Stator voltage

Last Answer : 1) Pole Changing Method:  Synchronous speed is given by, From the above equation of synchronous speed, it can be seen that synchronous speed (and hence, running speed) can ... in voltage and consequently the speed decreases and vice versa. Ultimately speed depends on the supply voltage.