7 The main advantage of auto transformer over a two winding transformer is
A. Hysteresis losses are reduced
B. Saving in winding material
C. Copper losses are negligible
D. Eddy losses are totally eliminated

1 Answer

Answer :

A) hysteresis losses is reduced

Related questions

Description : 42 The efficiency of a transformer will be maximum when A. copper losses = hysteresis losses B. Hysteresis losses = eddy current losses C. Eddy current losses = copper losses D. Copper losses = iron losses

Last Answer : D. Copper losses = iron losses

Description : 43 The purpose of providing an iron core in a transformer is to A.Provide support to windings B. Reduce hysteresis loss C. decrease the reluctance of the magnetic path D. reduce eddy current losses

Last Answer : C. Decrease the reluctance of the magnetic path

Description : 70] Silicon steel used in laminations mainly reduces A. Hysteresis loss B. Eddy current losses C. Copper loss D. All of the above

Last Answer : A. Hysteresis loss

Description : 9 Which loss is not common between a transformer and rotating machines? A. Eddy current loss B. Copper loss C. Windage loss D. Hysteresis loss

Last Answer : A. Eddy current loss

Description : 17. Which type of loss is not common to transformer and rotating machines? A. Eddy current loss B. Copper loss C. Hysteresis loss D. Windage loss

Last Answer : D. Windage loss

Description : 8 The transformer core is laminated to A. Reduce the copper losses B. Reduce the core losses C. Reduce the eddy current losses D. None of the above

Last Answer : C. Reduce the eddy current losses

Description : A 220/440 V, 50 Hz, 5 KVA, single phase transformer operates on 220V, 40Hz supply with secondary winding open circuited. Then (A) Both eddy current and hysteresis losses decreases. (B) Both ... same but hysteresis loss increases. (D) Eddy current loss increases but hysteresis loss remains the same.

Last Answer : (A) Both eddy current and hysteresis losses decreases.

Description : Which of the following losses is/are present in every direct current generator armature? A. Winding copper loss B. Core eddy current loss C. Magnetic hysteresis loss D. All of the above.

Last Answer : Answer: D

Description : 69 In case there are burrs on the edges of the laminations of the transformer, it is likely to result in A. Vibrations B. Noise C. Higher eddy currents loss D. Higher hysteresis loss

Last Answer : C. Higher eddy currents loss

Description : 24 Transformer cores are laminated in order to A. simplify its construction B. minimise eddy current loss C. reduce cost D. reduce hysteresis loss

Last Answer : B. Minimise eddy current loss

Description : A transformer at 25 Hz develops 20 W hysteresis loss and 50 W eddy current loss. If the applied voltage and frequency are doubled, the new core losses are (A) 140 W (B) 180 W (C) 240 W (D) 480 W

Last Answer : A transformer at 25 Hz develops 20 W hysteresis loss and 50 W eddy current loss. If the applied voltage and frequency are doubled, the new core losses are 240 W

Description : [53] The iron loss of the transformer is negligible during short circuit test because A. The entire input is just sufficient to meet Cu losses only B. Flux produced is a small fraction of the normal flux C. Iron core becomes fully saturated D. Supply frequency is held constant

Last Answer : B. Flux produced is a small fraction of the normal flux

Description : During short circuit test iron losses are negligible because A. The current on secondary side is negligible B. The voltage on secondary side does not vary C. The voltage applied on primary side is low D. Full-load current is not supplied to the transformer

Last Answer : C) the voltage applied on primary side is low

Description : During short circuit test iron losses are negligible because A. The current on secondary side is negligible B. The voltage on secondary side does not vary C. The voltage applied on primary side is low D. Full-load current is not supplied to the transformer

Last Answer : C) the voltage applied on primary side is low

Description : [75] Two transformers are connected in parallel. These transformers do not have equal percentage impedance which results A. Short-circuiting of the secondaries B. Power factor of one of the ... have negligible core losses D. Loading of the transformers not in proportion to their kVA ratings.

Last Answer : D. Loading of the transformers not in proportion to their kVA ratings

Description : 19 Transformer cores are built up from laminations rather than from solid metal so that A. Oil penetrates the core more easily B. Eddy current loss is reduced C. Less lamination is required for the windings D. Turn ratio is higher than voltage ratio

Last Answer : B. Eddy current loss is reduced

Description : The hysteresis and eddy current losses of a single phase transformer working on 200 V, 50 Hz supply are Ph and Pe respectively. The percentage decrease in these when operated on a 160 V, 40 Hz supply are   (a) 32, 36 (b) 20, 36 (c) 25, 50 (d) 40, 80 

Last Answer : The hysteresis and eddy current losses of a single phase transformer working on 200 V, 50 Hz supply are Ph and Pe respectively. The percentage decrease in these when operated on a 160 V, 40 Hz supply are 20, 36

Description : The armature of a dc machine is laminated to reduce: (A) Eddy current loss (B) Hysteresis loss (C) copper losses (D) friction and windage losses

Last Answer : Ans: A Thinner the laminations, greater is the resistance offered to the induced e.m.f., smaller the current and hence lesser the I2R loss in the core.

Description : Which of the following properties is not necessarily desirable in the material for transformer core? A. Mechanical strength B. Low hysteresis loss C. High thermal conductivity D. High permeability

Last Answer : C) high thermal conductivity

Description : During short circuit test iron losses are negligible because?

Last Answer : During short circuit test iron losses are negligible because the voltage applied on primary side is low.

Description : 64)During the short-circuit test on a small transformer the frequency is increased from 50-200Hz. The copper losses will increase by a factor of A. 16 B. 4 C. 1 D. 1/4

Last Answer : A) 16

Description : 45 The function of conservator in a transformer is A. To protect against internal fault B. To reduce copper as well as core losses C. To cool the transformer oil D. To take care of the expansion and contraction of transformer oil due to variation of temperature of surroundings

Last Answer : D. To take care of the expansion and contraction of transformer oil due to variation of temperature of surroundings

Description : Auto-transformer makes effective saving on copper and copper losses, when its transformation ratio is?

Last Answer : Auto-transformer makes effective saving on copper and copper losses, when its transformation ratio is approximately equal to 1.

Description : Eddy current losses in transformer cores can be reduced by the use of  1. Solid cores  2. Laminated cores  3. Ferrites  Select the correct answer using the codes given below : (a) 2 and 3 only (b). 1 and 2 only (c) 1 and 3 only (d) 1, 2 and 3

Last Answer : Eddy current losses in transformer cores can be reduced by the use of  1. Solid cores  2. Laminated cores  3. Ferrites  Select the correct answer using the codes given below : (a) 2 and 3 only (b). 1 and 2 only (c) 1 and 3 only (d) 1, 2 and 3

Description : What is hysteresis loss in transformer?

Last Answer : The magneto motive force or mmf applied in the transformer core is alternating. For every cycle due to this domain reversal, there will be extra work done. For this reason, there will be a consumption of electrical energy which is known as Hysteresis loss of transformer.

Description : What is Eddy current loss in transformer?

Last Answer : In transformer, we supply alternating current in the primary, this alternating current produces alternating magnetizing flux in the core and as this flux links with secondary winding, there will be induced ... dissipated as heat. This type of energy loss is called eddy current loss of transformer.

Description : The armature cores of the D.C. motors are constructed with laminations to ___________. A. eliminate hysteresis B. minimize brush sparking C. reduce eddy current losses D. compensate for armature reaction

Last Answer : Answer: C

Description : The armature cores of the D.C. motors are constructed with laminations to ___________. A. eliminate hysteresis B. minimize brush sparking C. reduce eddy current losses D. compensate for armature reaction

Last Answer : Answer: C

Description : Armature cores in a DC generator are made of laminated steel sheets to _____________. A. fit the curvature of the frame B. increase the hysteresis effect C. reduce eddy current losses D. allow for easy assembly

Last Answer : Answer: C

Last Answer : No eddy current and hysteresis losses occur in Electrostatic instruments.

Description : What is Two winding transformer?

Last Answer : Two separate windings one as primary and other as secondary are used. Both windings are magnetically coupled.

Description : 28.In a two winding transformer, the emf /turn in secondary winding is always......the induced emf power turn in primary A. equal to k times B. equal to 1/k times C. equal D. greater than

Last Answer : C. equal

Description : 27] In a transformer, the leakage flux of each winding is proportional to the current in that winding because A. Ohm's law applies to magnetic circuits B. Leakage paths do no saturate C. the two windings are electrically isolated D. mutual flux is confined to the core

Last Answer : B. Leakage path do not saturate

Description : 6 In a two winding transformer, the primary and secondary induced emf E1 & E2 are always A. equal in magnitude B. anti phase with each other C. in phase with each other D. determined by load on transformer secondary

Last Answer : C. In phase with each other

Description : What is tertiary winding? What is Three Winding Transformer? What are its advantages?

Last Answer : A. In some high rating transformers, one winding, in addition to the primary and secondary winding, is used. This is known as Tertiary Winding of Transformer. Because of this third winding, the ... it assists in limitation of fault current in the event of a short circuit from line to neutral.

Description : What are the necessary tests to determine the efficiency, voltage regulation, and temperature rise of winding & insulation of transformer?

Last Answer : 1.Direct loading test 2.Open circuit test 3. Short circuit test 4. Sumpner's or back to back test

Description : What is Six winding transformer?

Last Answer : Three windings in primary and three windings in secondary are used, They are three phase transformers.They are connected in either star-star, delta-delta, star delta or delta star.

Description : What is Three winding transformer?

Last Answer : Three windings are used each work as primary and secondary. Also primary and secondary windings are conductively couple. They are three phase auto transformer

Description : 12] Which is not the basic element of the transformer? A. core B. primary winding C. secondary winding D. mutual flux

Last Answer : D. Mutual flux

Description : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Last Answer : A certain transformer has 200 turns in the primary winding, 50 turns in the secondary winding and 120 volts applied to the primary. What is the voltage across the secondary?  (A) 30 Volts (B) 480 Volts (C) 120 Volts (D) 60 Volts

Last Answer : The short circuit in any winding of the transformer is the result of impulse voltage.

Last Answer : In the transformer low voltage winding has got more cross-sectional area.

Last Answer : Primary winding of a transformer could either be a low voltage or high voltage winding.

Last Answer : High voltage winding in a transformer has more number of turns.

Last Answer : High voltage winding of the transformer has less cross-sectional area.

Last Answer :  Sandwich type winding is used in 3 phase shell-type transformer.

Last Answer : yes High Voltage side of Transformer winding have more number of turns. and low voltage side of Transformer winding have less number of turns.

Description : 21.The ordinary two winding transformer's primary and secondary windings always have A. different no of turns B. same size of copper wire C. a common magnetic circuit D. separate magnetic circuits

Last Answer : C. A common magnetic circuit

Description : What are the transformer losses?

Last Answer : Answer: TRANSFORMER LOSSES - There are mainly two kinds of losses in a transformer namely 1. Copper loss (ohmic loss) and 2.magnetic loss (core loss). Copper losses are caused by the ... ohmic loss the following two losses are also present in the transformer stray load loss and dielectric loss.

Description : Explain about the losses in Transformer?

Last Answer : TRANSFORMER LOSSES - Transformer losses have two sourcescopper loss and magnetic loss. Copper losses are caused by the resistance of the wire (I2R). Magnetic losses are caused by eddy currents ... current. Eddy-current loss, however, is different for each frequency passed through the transformer.